Advances in implantable radio-telemetry or diverse biologging devices capable of acquiring high-resolution ambulatory electrocardiogram (ECG) or heart rate recordings facilitate comparative physiological investigations by enabling detailed analysis of cardiopulmonary phenotypes and responses in vivo. Two priorities guiding the meaningful adoption of such technologies are: (1) automation, to streamline and standardize large dataset analysis, and (2) flexibility in quality-control. The latter is especially relevant when considering the tendency of some fully automated software solutions to significantly underestimate heart rate when raw signals contain high-amplitude noise.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
April 2017
Purpose: Electromagnetic (EM) catheter tracking has recently been introduced in order to enable prompt and uncomplicated reconstruction of catheter paths in various clinical interventions. However, EM tracking is prone to measurement errors which can compromise the outcome of the procedure. Minimizing catheter tracking errors is therefore paramount to improve the path reconstruction accuracy.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
March 2015
Purpose: Electromagnetic (EM) tracking of instruments within a clinical setting is notorious for fluctuating measurement performance. Position location measurement uncertainty of an EM system was characterized in various environments, including control, clinical, cone beam computed tomography (CBCT), and CT scanner environments. Static and dynamic effects of CBCT and CT scanning on EM tracking were evaluated.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
January 2014
Introduction: In patients with normal hearts, increased vagal tone is associated with onset of paroxysmal atrial fibrillation (AF). Vagal denervation of the atria renders AF less inducible. Circumferential pulmonary vein isolation (CPVI) is effective for treating paroxysmal and persistent AF, and has been shown to impact heart rate variability (HRV) indices, in turn, reflecting vagal denervation.
View Article and Find Full Text PDFWe designed a novel approach for multi-lead QRS detection. The algorithm uses one equation with two different window widths to generate a feature signal and a detection threshold. This enables it to adapt to various changes in QRS morphology and noise levels, resulting in a detection error rate of just 0.
View Article and Find Full Text PDFAims: Catheter ablation for paroxysmal atrial fibrillation (AF) is rapidly becoming a standard practice. There is literature to support that catheter ablation of persistent AF requires additional 'substrate modification'. In clinical practice, operators rely on automated fractionation maps created by three-dimensional anatomic mapping systems to rapidly assess complex 'fractionated' signals (CFAE).
View Article and Find Full Text PDF