Publications by authors named "Seidensticker P"

In the world of nuclear medicine, health care professionals face the challenge of safeguarding themselves and their patients from occupational radiation exposure. As the field experiences exponential growth, driven by the surge in approvals of radiopharmaceuticals for diagnostic and therapeutic applications, it becomes vital to delve into the delivery methods of radiopharmaceuticals. Health care professionals take precautions during radiopharmaceutical administration, including maintaining distance from radioactive sources, using shielding, limiting exposure time, and monitoring radiation levels with badges.

View Article and Find Full Text PDF

Rationale And Objectives: Coronary CT angiography (CCTA) has recently been established as a first-line test in patients with suspected coronary artery disease (CAD). Due to the increased use of CCTA, strategies to reduce radiation and contrast medium (CM) exposure are of high importance. The aim of this study was to evaluate the performance of automated tube voltage selection (ATVS)-adapted CM injection protocol for CCTA compared to a clinically established triphasic injection protocol in terms of image quality, radiation exposure, and CM administration MATERIAL AND METHODS: Patients undergoing clinically indicated CCTA were prospectively enrolled from July 2021 to July 2023.

View Article and Find Full Text PDF

Background: Contrast-enhanced mammography (CEM) is an emerging breast imaging modality. Clinical data is scarce.

Objectives: To summarize clinical evidence on the use of iopromide in CEM for the detection or by systematically analyzing the available literature on efficacy and safety.

View Article and Find Full Text PDF

Over the past 120 years, continuous developments in medical imaging has improved diagnosis and treatment for many diseases and has thereby improved treatment outcome and quality of life of many patients. The number of computed tomography (CT) examinations is today increasing by 4% per year worldwide, for a total of approximately 300 million CT scans per year. About 40% of CT scans are contrast enhanced.

View Article and Find Full Text PDF

Objective: To assess the effect of low-osmolar, monomeric contrast media with different iodine concentrations on bolus shape in aortic CT angiography.

Materials And Methods: Repeated sequential computed tomography scanning of the descending aorta of eight beagle dogs (5 male, 12.7±3.

View Article and Find Full Text PDF

Rationale And Objectives: Computed tomography angiography source imaging (CTA-SI) in acute ischemic stroke improves detection rate and estimation of extent of cerebral infarction. This study compared the new components color-coded perfusion weighted map (PWM) and color-coded perfused blood volume (PBV) derived from CTA data with CTA-SI for the visualization of cerebral infarction.

Materials And Methods: Fifty patients (women = 30; mean age = 74.

View Article and Find Full Text PDF

Objective: The purpose of this article is to prospectively assess the frequency and type of IV injection site complications associated with high-flow power injection of nonionic contrast medium in MDCT.

Subjects And Methods: Contrast-enhanced (300-370 mg iodine/mL) MDCT examinations with high flow rates (up to 8 mL/s) using automatic CT injectors were performed according to standardized MDCT protocols. The location, type, and size (16-24 gauge) of IV catheters and volumes, iodine concentration, and flow rates of contrast medium were documented.

View Article and Find Full Text PDF

Aim: To evaluate the impact of bone subtraction computed tomography angiography (BS-CTA) for the assessment of transcranial arteries in comparison with standard CTA (S-CTA) without bone removal and time-of-flight magnetic resonance angiography (TOF-MRA).

Materials And Methods: Cranial unenhanced CT and S-CTA were performed in 53 patients with suspected cerebrovascular disease. BS-CTA datasets were reconstructed from the S-CTA and unenhanced CT source images.

View Article and Find Full Text PDF

Objective: To prospectively investigate the influence of contrast material concentration on enhancement in cardiac CT by using a biphasic single-injection protocol.

Methods: Sixty-four-row multidetector cardiac CT angiography was performed in 159 patients randomised to a moderate or high contrast medium concentration. Contrast material injection included a first phase for enhancement of the coronary arteries and a second phase, at half the iodine flux, targeted at enhancement of the right ventricle.

View Article and Find Full Text PDF

Objective: To compare intra-individual contrast enhancement in multi-detector-row computed tomography (MDCT) using contrast media (CM) containing 300, 370 and 400 mg iodine per ml (mgI/ml).

Methods: Six pigs underwent repeated chest MDCT using three different CM (iopromide 300, iopromide 370, iomeprol 400). An identical iodine delivery (IDR) rate of 1.

View Article and Find Full Text PDF

Rationale And Objectives: This study determines the value of whole brain color-coded three-dimensional perfused blood volume (PBV) computed tomography (CT) for the visualization of the infarcted tissue in acute stroke patients.

Materials And Methods: Nonenhanced CT (NECT), perfusion CT (PCT), and CT angiography (CTA) in 48 patients with acute ischemic stroke were performed. Whole brain PBV was calculated from NECT and CTA data sets using commercial software.

View Article and Find Full Text PDF

Objectives: Computed tomography angiography (CTA) is a well-accepted imaging modality to evaluate the supraaortic vessels. Initial reports have suggested that dual energy CTA (DE-CTA) can enhance diagnosis by creating bone-free data sets, which can be visualized in 3D, but a number of limitations of this technique have also been addressed. We sought to describe the performance of DE-CTA of the supraaortic vessels with a novel dual source CT system with special emphasis on image quality and post-processing related artifacts.

View Article and Find Full Text PDF

Objectives: Noninvasive imaging is increasingly accepted for the evaluation of atherosclerotic disease of the carotid arteries. We sought to evaluate the feasibility of a low-contrast media volume protocol for carotid computed tomography angiography (CTA) using a 128-slice-spiral-computed tomography scanner with a gantry rotation time of 300 milliseconds.

Methods And Materials: Thirty consecutive patients underwent CTA for the evaluation of the carotid vessels, with a 128-section scanner.

View Article and Find Full Text PDF

Rationale And Objectives: We sought to intraindividually compare intravascular contrast enhancement in multidector computed tomography (MDCT) of the chest using contrast media (CM) containing 300 and 400 mg iodine/ml.

Materials And Methods: Seventy-one patients underwent repeated MDCT scanning of the chest at baseline and follow-up. CM with standard iodine (protocol A: 300 mg iodine/ml; Iopromide 300) and high iodine concentration (protocol B: 400 mg iodine/ml; Iomeprol 400) were used.

View Article and Find Full Text PDF

Background: Previous experiences of whole body MR angiography are predominantly available in linear 0.5 M gadolinium-containing contrast agents. The aim of this study was to compare image quality on a four-point scale (range 1-4) and diagnostic accuracy of a 1.

View Article and Find Full Text PDF

Objective: Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The objective of this preclinical study is to assess differences of a low and high-viscous CM regarding their retention time in the kidney.

View Article and Find Full Text PDF

Purpose: To prospectively assess a dose-response relationship for the hepatic reticulo-endothelial system (RES) after small volume single fraction irradiation of liver parenchyma in vivo.

Materials And Methods: Twenty-five liver tumors were treated by computed tomography (CT)-guided interstitial brachytherapy. Magnetic resonance imaging (MRI) was performed 1 day before and 3 days, 6, 12 and 24 weeks after therapy.

View Article and Find Full Text PDF

To evaluate the influence of different types of iodinated contrast media on the assessment of myocardial viability, acute myocardial infarction (MI) was surgically induced in six rabbits. Over a period of 45 min, contrast-enhanced cardiac MDCT (64 x 0.6 mm, 80 kV, 680 mAs(eff.

View Article and Find Full Text PDF

In computed tomography (CT) several contrast media with different iodine concentrations are available. The aim of this study is to prospectively compare contrast media with iodine concentrations of 300, 370 and 400 mg iodine/ml for chest- CT. 300 consecutive patients were prospectively enrolled, under a waiver of the local ethics committee.

View Article and Find Full Text PDF

Objective: The purpose of this study was an intraindividual comparison of the degrees of MDCT contrast enhancement achieved with agents containing 300 and 370 mg I/mL.

Subjects And Methods: Seventy-five patients underwent baseline and follow-up MDCT of the chest and abdomen with contrast media containing a high concentration of iodine (iopromide 370 mg I/mL) and standard iodine concentration (iopromide 300 mg I/mL). The total iodine load (37 g) and the iodine delivery rate (1.

View Article and Find Full Text PDF

Objective: It was the aim of this study to evaluate a new infiltration score to determine the resectability of pancreatic carcinomas in preoperative planning.

Materials And Methods: Eighty patients with suspected pancreatic tumor were examined prospectively using 16-row spiral CT. The scans were evaluated for the presence of pancreatic carcinoma, peripancreatic tumor extension and vascular invasion using a standardized questionnaire.

View Article and Find Full Text PDF

To compare the impact of iodine concentration using two different contrast materials (CM) at standardized iodine delivery rate (IDR) and overall iodine load in 16-multidetector-row-CT-angiography (MDCTA) of the pulmonary arteries of 192 patients with known or suspected pulmonary embolism. One hundred three patients (group A) received 148 ml of a CM containing 300 mg iodine/ml (Ultravist 300, BayerScheringPharma) at a flow rate of 4.9 ml/s.

View Article and Find Full Text PDF

Background: We performed a prospective study on patients with middle cerebral artery(MCA) ischemic stroke to evaluate the accuracy of perfusion-CT imaging(PCT) to predict the development of malignant brain infarction (MBI).

Methods: 106 patients(women 37 %, mean age 65 years)underwent native cranial computed tomography (CCT), CT angiography(CTA) and PCT after a median of 2 h after stroke onset. We assessed the patency of the MCA and the area of tissue ischemia (AIT)according to cerebral blood flow(CBF), cerebral blood volume (CBV) and time-to-peak (TTP)maps.

View Article and Find Full Text PDF

The purpose of this study was to intraindividually evaluate the difference in intraluminal vessel and parenchyma contrast enhancement of two different iodine concentrations in multidetector-row computed tomography (MDCT) of the abdomen. Eighty-three patients underwent baseline and follow-up MDCT-scanning (Somatom Sensation 16; Siemens, Forchheim, Germany) of the abdomen using contrast media containing 370 mg iodine/ml (protocol A; Ultravist 370, Bayer Schering Pharma, Berlin, Germany) and 300 mg iodine/ml (protocol B; Ultravist 300). The total iodine load (37 g iodine) and the iodine delivery rate (1.

View Article and Find Full Text PDF