Abdom Radiol (NY)
January 2025
Objective: In-bore MRI-guided biopsy allows direct visualization of suspicious lesions, biopsy needles, and trajectories, allowing accurate sampling when MRI-ultrasound fusion biopsy is not feasible. However, its use has been limited. Wide-bore, lower-field, and lower-cost scanners could help address these issues, but their feasibility for prostate biopsy is unknown.
View Article and Find Full Text PDFPurpose: To compare image quality, assess inter-reader variability, and evaluate the diagnostic efficacy of routine clinical lumbar spine sequences at 0.55T compared with those collected at 1.5/3T to assess common spine pathology.
View Article and Find Full Text PDFRationale And Objectives: This study aims to assess the quality of abdominal MR images acquired on a commercial 0.55T scanner and compare these images with those acquired on conventional 1.5T/3T scanners in both healthy subjects and patients.
View Article and Find Full Text PDFCardiac Magnetic Resonance (CMR) protocols can be lengthy and complex, which has driven the research community to develop new technologies to make these protocols more efficient and patient-friendly. Two different approaches to improving CMR have been proposed, specifically "all-in-one" CMR, where several contrasts and/or motion states are acquired simultaneously, and "real-time" CMR, in which the examination is accelerated to avoid the need for breathholding and/or cardiac gating. The goal of this two-part manuscript is to describe these two different types of emerging rapid CMR protocols.
View Article and Find Full Text PDFCardiovascular magnetic resonance (CMR) protocols can be lengthy and complex, which has driven the research community to develop new technologies to make these protocols more efficient and patient-friendly. Two different approaches to improving CMR have been proposed, specifically "all-in-one" CMR, where several contrasts and/or motion states are acquired simultaneously, and "real-time" CMR, in which the examination is accelerated to avoid the need for breathholding and/or cardiac gating. The goal of this two-part manuscript is to describe these two different types of emerging rapid CMR.
View Article and Find Full Text PDFJ Magn Reson Imaging
November 2024
Cardiovascular magnetic resonance (CMR) is an established imaging modality with proven utility in assessing cardiovascular diseases. The ability of CMR to characterize myocardial tissue using T- and T-weighted imaging, parametric mapping, and late gadolinium enhancement has allowed for the non-invasive identification of specific pathologies not previously possible with modalities like echocardiography. However, CMR examinations are lengthy and technically complex, requiring multiple pulse sequences and different anatomical planes to comprehensively assess myocardial structure, function, and tissue composition.
View Article and Find Full Text PDFPurpose: To develop a deep image prior (DIP) reconstruction for B -corrected 2D cine MR fingerprinting (MRF).
Methods: The proposed method combines low-rank (LR) modeling with a DIP to generate cardiac phase-resolved parameter maps without motion correction, employing self-supervised training to enforce consistency with undersampled spiral k-space data. Two implementations were tested: one approach (DIP) for cine T , T , and M mapping, and a second approach (DIP with effective B estimation [DIP-B1]) that also generated an effective B map to correct for errors due to RF transmit inhomogeneities, through-plane motion, and blood flow.
Magn Reson Imaging Clin N Am
February 2024
Perfusion imaging techniques provide quantitative characterization of tissue microvasculature. Perfusion MR of liver is particularly challenging because of dual afferent flow, need for large organ high-resolution coverage, and significant movement with respiration. The most common MR technique used for quantifying liver perfusion is dynamic contrast-enhanced MR imaging.
View Article and Find Full Text PDFLate gadolinium enhancement (LGE) MRI is the non-invasive reference standard for identifying myocardial scar and fibrosis but has limitations, including difficulty delineating subendocardial scar and operator dependence on image quality. The purpose of this work is to assess the feasibility of generating multi-contrast synthetic LGE images from post-contrast T and T maps acquired using magnetic resonance fingerprinting (MRF). Fifteen consecutive patients with a history of prior ischemic cardiomyopathy (12 men; mean age 63 13 years) were prospectively scanned at 1.
View Article and Find Full Text PDFThe purpose of this study was to assess the quality of clinical brain imaging in healthy subjects and patients on an FDA-approved commercial 0.55 T MRI scanner, and to provide information about the feasibility of using this scanner in a clinical workflow. In this IRB-approved study, brain examinations on the scanner were prospectively performed in 10 healthy subjects (February-April 2022) and retrospectively derived from 44 patients (February-July 2022).
View Article and Find Full Text PDFPurpose: To develop and evaluate a 3D sector-wise golden-angle (3D-SWIG) profile ordering scheme for cardiovascular MR cine imaging that maintains high k-space uniformity after electrocardiogram (ECG) binning.
Method: Cardiovascular MR (CMR) was performed at 1.5 T.
Background: Cardiac magnetic resonance fingerprinting (cMRF) enables simultaneous mapping of myocardial T1 and T2 with very short acquisition times. Breathing maneuvers have been utilized as a vasoactive stress test to dynamically characterize myocardial tissue . We tested the feasibility of sequential, rapid cMRF acquisitions during breathing maneuvers to quantify myocardial T1 and T2 changes.
View Article and Find Full Text PDFObjective: This study combines a deep image prior with low-rank subspace modeling to enable real-time (free-breathing and ungated) functional cardiac imaging on a commercial 0.55 T scanner.
Materials And Methods: The proposed low-rank deep image prior (LR-DIP) uses two u-nets to generate spatial and temporal basis functions that are combined to yield dynamic images, with no need for additional training data.
Purpose Of Review: Cardiac magnetic resonance fingerprinting (cMRF) has developed as a technique for rapid, multi-parametric tissue property mapping that has potential to both improve cardiac MRI exam efficiency and expand the information captured. In this review, we describe the cMRF technique, summarize technical developments and in vivo reports, and highlight potential clinical applications.
Recent Findings: Technical developments in cMRF continue to progress rapidly, including motion compensated reconstruction, additional tissue property quantification, signal time course analysis, and synthetic LGE image generation.
In the following case series, we describe the clinical presentation of 2 patients with myocardial infarction with nonobstructive coronary arteries with different underlying pathophysiologic mechanisms. In both scenarios, cardiac magnetic resonance (CMR) imaging provided comprehensive tissue characterization with both conventional parametric mapping techniques and CMR fingerprinting. These cases demonstrate the diagnostic utility for CMR to elucidate the underlying etiology and appropriate therapeutic strategy.
View Article and Find Full Text PDFThis study presents a particle filter based framework to track cardiac surface from a time sequence of single magnetic resonance imaging (MRI) slices with the future goal of utilizing the presented framework for interventional cardiovascular magnetic resonance procedures, which rely on the accurate and online tracking of the cardiac surface from MRI data. The framework exploits a low-order parametric deformable model of the cardiac surface. A stochastic dynamic system represents the cardiac surface motion.
View Article and Find Full Text PDFWomen's engagement in medicine, and more specifically cardiovascular imaging and cardiovascular MRI (CMR), has undergone a slow evolution over the past several decades. As a result, an increasing number of women have joined the cardiovascular imaging community to contribute their expertise. This collaborative work summarizes the barriers that women in cardiovascular imaging have overcome over the past several years, the positive interventions that have been implemented to better support women in the field of CMR, and the challenges that still remain, with a special emphasis on women physicians.
View Article and Find Full Text PDFObjective: The goal of this work was to assess the feasibility of performing MRF in the liver on a 0.55 T scanner and to examine the feasibility of water-fat separation using rosette MRF at 0.55 T.
View Article and Find Full Text PDFThe goal of this work is to extend prior work on cardiac MR Fingerprinting (cMRF) using rosette k-space trajectories to enable simultaneous T, T, and proton density fat fraction (PDFF) mapping in the heart. A rosette trajectory designed for water-fat separation at 1.5T was used in a 2D ECG-triggered 15-heartbeat cMRF sequence.
View Article and Find Full Text PDFPurpose: Through-time spiral GRAPPA is a real-time imaging technique that enables ungated, free-breathing evaluation of the left ventricle. However, it requires a separate fully-sampled calibration scan to calculate GRAPPA weights. A self-calibrated through-time spiral GRAPPA method is proposed that uses a specially designed spiral trajectory with interleaved arm ordering such that consecutive undersampled frames can be merged to form calibration data, eliminating the separate fully-sampled acquisition.
View Article and Find Full Text PDFPurpose: To evaluate multicenter repeatability and reproducibility of T and T maps generated using MR fingerprinting (MRF) in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and in prostatic tissues.
Methods: MRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA) in the United States, and Diagnosticos da America (Rio de Janeiro, RJ) in Brazil. Raw MRF data were reconstructed using a Gadgetron-based MRF online reconstruction pipeline to yield quantitative T and T maps.