Publications by authors named "Sebastien Prevot"

Background: Achieving mitral isthmus (MI) block can be challenging. This prospective study evaluated the feasibility and efficacy of a systematic strategy comprising three consecutive steps to achieve MI block.

Methods: Twenty consecutive patients (mean (± SD) age 71.

View Article and Find Full Text PDF

Background: Postoperative conduction disorders are serious adverse events in patients undergoing aortic valve replacement, and may prolong the duration of hospitalization and require pacemaker insertion.

Aim: Our aim was to evaluate the rate of pacemaker insertion after implantation of an Edwards Intuity sutureless aortic valve (Edwards Lifesciences, Irvine, CA, USA) compared with a standard surgical bioprosthesis.

Methods: This retrospective single-centre study included patients who underwent aortic valve replacement with an Intuity sutureless aortic valve or a standard bioprosthetic valve between 4 June 2014 and 27 June 2016.

View Article and Find Full Text PDF

Background: Transvenous pacemaker (PM) implantation is a complication in patients undergoing transcatheter aortic valve implantation (TAVI). Recently, a second generation of leadless PMs able of atrioventricular (AV) synchronous pacing has been introduced and could be an alternative when ventricular pacing is required after TAVI. Real-world data on Micra AV after TAVI are still lacking.

View Article and Find Full Text PDF

Purpose: Diagnosis of atrial tachycardia (AT) with 3D mapping system remains challenging due to fibrosis or previous ablation. This study aims to evaluate a new electroanatomical mapping annotation setting using a window of interest adjusted at the end of the P wave (WOI) to identify the AT mechanism more accurately.

Methods: Twenty patients with successful ablation of left AT using navigation system CARTO3 were evaluated.

View Article and Find Full Text PDF

Aims: The European REMOTE-CIED study is the first randomized trial primarily designed to evaluate the effect of remote patient monitoring (RPM) on patient-reported outcomes in the first 2 years after implantation of an implantable cardioverter-defibrillator (ICD).

Methods And Results: The sample consisted of 595 European heart failure patients implanted with an ICD compatible with the Boston Scientific LATITUDE® RPM system. Patients were randomized to RPM plus a yearly in-clinic ICD check-up vs.

View Article and Find Full Text PDF

Purpose: Elimination of the negative component of the unipolar atrial electrogram is a reliable indicator of the creation of a transmural lesion. Contact-force (CF) sensing technology has the potential to increase the durability of pulmonary vein isolation (PVI). In the present multicenter study, we assessed the 2-year sinus rhythm (SR) maintenance rate in patients with paroxysmal atrial fibrillation (PAF) after PVI guided by these two approaches.

View Article and Find Full Text PDF
Article Synopsis
  • Remote patient monitoring (RPM) for implantable cardioverter defibrillators (ICDs) might be just as good as regular doctor visits and could save money, but it's not very common in Europe.
  • Most studies on RPM haven't focused on how patients feel about it, but some suggest that patients are generally happy with it.
  • More research is needed to understand patients' views better, and a new study starting soon will help find out what makes patients happy with RPM.
View Article and Find Full Text PDF

Background: Right phrenic nerve palsy (PNP) is the most frequent complication of cryoballoon ablation. Diaphragmatic electromyography can predict PNP with a comfortable safety margin. Our goal was to evaluate the feasibility, efficacy, and safety of electromyography-guided PN monitoring using a novel hepatic vein approach for prevention of PNP.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to investigate the hypothesis that responses to the ATP test and head-up tilt test (HUT) may be correlated with different purinergic profiles.

Design And Setting: The ATP and HUT identify distinct subsets of patients with neurally mediated syncope (NMS). Adenosine and its A(2A) receptors (A(2A)R) may be implicated in the pathophysiology of NMS in patients with positive HUT.

View Article and Find Full Text PDF

Objective: To assess long-term outcomes and predictors of mortality in patients treated according to current recommendations for cardiac implantable electronic device (CIED) infection.

Design: Two-group matched cohort study.

Setting: Tertiary-care institution.

View Article and Find Full Text PDF

Aims: Isthmus-dependent (ID) clockwise (CW) atrial flutters (AFl) are rare in comparison with counterclockwise (CCW) AFl. Little is known about clinical and electrophysiological characteristics of CW AFl occurring after previous radiofrequency (RF) catheter ablation of CCW AFl. We sought to compare CW AFl de novo vs.

View Article and Find Full Text PDF

Background: Alcohol septal ablation (ASA) is a therapeutic catheter-based option and an alternative to surgical myectomy in the treatment of patients with hypertrophic obstructive cardiomyopathy. Although the safety of the ASA procedure has been consistently improved, a temporary transvenous pacemaker is recommended for at least 48h postprocedure, with several drawbacks, including the risk of cardiac perforation and infection, and the absence of any fixation mechanism. In addition, femoral artery catheterization has resulted in a concomitant increase in bleedings and iatrogenic femoral artery injuries.

View Article and Find Full Text PDF

Background: Although risks and life-threatening complications associated with lead extraction are well characterized, practice patterns vary regarding whether procedures are performed in an operating room (OR) or electrophysiology (EP) laboratory with cardiothoracic surgical backup.

Objective: Our objective was to compare procedural outcomes and complications associated with lead extraction in the OR vs. EP laboratory.

View Article and Find Full Text PDF

Objectives: We sought to determine the incidence, diagnostic value, and outcome of intracardiac masses observed by echocardiography after device removal. We hypothesized that these "ghosts" of leads could be associated with the diagnosis of cardiac device-related infective endocarditis (CDRIE).

Background: The echocardiographic appearance of residual floating masses in the right atrium after removal of permanent pacemakers and implantable cardioverter-defibrillators was recently described.

View Article and Find Full Text PDF

Cardiac resynchronization therapy (CRT) is an effective treatment of heart failure in selected patients. However, with conventional CRT, notable left ventricular (LV) reverse remodelling is achieved in only 60-70% of patients. This lack of effect of CRT might be due to incomplete resynchronization.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess how often traumatic tricuspid regurgitation (TTR) occurs after the removal of implanted heart leads, identifying risk factors and patient outcomes.
  • Of 208 patients with 237 lead removals, 9.1% developed TTR, with higher risks linked to using laser sheath tools and being female.
  • Long-term follow-up showed that severe TTR was associated with considerable complications, including new symptoms of heart failure in some patients and mortality for others, emphasizing the need for careful monitoring.
View Article and Find Full Text PDF
Article Synopsis
  • Clinical trials show that right ventricular apical pacing can lead to negative health outcomes, like heart dysfunction and long-term risks.
  • The study highlights how different pacing sites (right, left, and biventricular) can have both harmful and beneficial effects on heart function.
  • An algorithm is suggested to help guide the choice of pacing methods based on factors like heart conduction, left ventricular health, and patient lifespan.
View Article and Find Full Text PDF