Background: Reliable blood glucose (BG) measurements are important for people with diabetes to manage their therapy as well as in point-of-care testing (POCT) performed by health care professionals to monitor BG of patients or even to diagnose diabetes. Among other factors, endogenous and exogenous substances present in blood samples can impact the measurement results. To ensure and prove that blood glucose monitoring systems (BGMSs) are robust in terms of potential interferents, manufacturers have to perform extensive evaluations.
View Article and Find Full Text PDFBackground: Blood glucose monitoring systems (BGMSs) are a cornerstone in diabetes management. They have to provide sufficiently accurate results in the hands of lay users, particularly in insulin-treated patients. The aim of this study was user performance evaluation and system accuracy assessment of four BGMSs with color coding of results.
View Article and Find Full Text PDFBackground: The increased use of continuous glucose monitoring (CGM) and automated insulin delivery systems raises the question about therapeutic targets for glucose profiles in people with diabetes. This study aimed to assess averaged pre- and postprandial glucose profiles in people without diabetes to provide guidance for normal glucose patterns in clinical practice. For that, number and timing of meal intake were predefined.
View Article and Find Full Text PDFFor decades, self-monitoring of blood glucose (SMBG) has been considered a cornerstone of adequate diabetes management. Structured SMBG can follow different monitoring patterns, and it results in improved glycemic control, reduced hypoglycemia, and a better quality of life of people with diabetes. The technology, usability, and accuracy of SMBG systems have advanced markedly since their introduction a few decades ago.
View Article and Find Full Text PDFBackground: Continuous glucose monitoring-derived parameters are becoming increasingly important in the treatment of people with diabetes. The aim of this study was to assess whether these parameters, as calculated from different continuous glucose monitoring systems worn in parallel, are comparable. In addition, clinical relevance of differences was investigated.
View Article and Find Full Text PDFBackground: Measurement accuracy has been assessed for many different blood glucose monitoring systems (BGMS) over the years by different study groups. However, the choice of the comparison measurement procedure may impact the apparent level of accuracy found in such studies.
Materials And Methods: Measurement accuracy of 18 different BGMS was assessed in a setting based on ISO 15197 using two different comparison methods in parallel: a glucose oxidase (GOD)-based and a hexokinase (HK)-based method.
J Diabetes Sci Technol
January 2021
Background: Noninvasive glucose monitoring (NIGM) in diabetes is a long-sought-for technology. Among the many attempts Raman spectroscopy was considered as the most promising because of its glucose specificity. In this study, a recently developed prototype (GlucoBeam, RSP Systems A/S, Denmark) was tested in patients with type 1 diabetes to establish calibration models and to demonstrate proof of concept for this device in real use.
View Article and Find Full Text PDFCartilage and bone are severely affected by glucocorticoids (GCs), steroid hormones that are frequently used to treat inflammatory diseases. Major complications associated with long-term steroid therapy include impairment of cartilaginous bone growth and GC-induced osteoporosis. Particularly in arthritis, GC application can increase joint and bone damage.
View Article and Find Full Text PDFThe functional insect ecdysteroid receptor is comprised of two nuclear receptors, the ecdysteroid receptor (EcR) and the RXR homologue, ultraspiracle (USP), which form a heterodimer. The dimer recognizes various hormone response elements and the effect of these elements on transcriptional activity of EcR isoforms was determined in vertebrate cells transfected with EcR and USP. Only constitutive activity mediated by the core response elements was preserved after elimination of nonspecific binding sites on the DNA of the vector.
View Article and Find Full Text PDFIn edible dormice (Glis glis) reproduction is synchronised with the intermittent masting of the European beech (Fagus sylvatica). In years of mast failure dormouse males seem to anticipate future low food availability and fail to develop functional testes. We hypothesised that the availability of high-quality food is linked to male reproductive capacity, because of high male energetic demands during gonad maturation.