Background: Periodontal scaling might cause musculoskeletal disorders, and scaling instruments might not only have different effectiveness and efficiency but also differ in their ergonomic properties. The present study assessed ergonomic working patterns of experienced (EO) and less experienced operators (LO) when using hand and powered devices for periodontal scaling and root planning.
Methods: In an experimental study using periodontally affected manikins, sonic (AIR), ultrasonic (TIG) and hand instruments (GRA) were used by 11 operators (7 EO/4 LO) during simulated supportive periodontal therapy.
Background: There is uncertainty regarding the benefits and risks of hand versus powered root surface instrumentation. Moreover, the influence of operators' experience on treatment results is unclear. We compared newly developed sonic, ultrasonic and hand instruments, hypothesizing that powered devices allow to remove more simulated plaque in less time than hand instruments, with significant influence of operators' experience.
View Article and Find Full Text PDF