The current literature suggests that up to 55% of complications after plate osteosynthesis treatment for patients with proximal humerus fractures are attributed to the surgical procedure. The hypothesis of this study was that a standardized surgical protocol would minimize surgery-related adverse events. This prospective cohort study included 50 patients with a mean age of 63.
View Article and Find Full Text PDFHypothesis: We hypothesized that treatment of rotator cuff arthropathy (RCA) with reverse shoulder arthroplasty (RSA) and an additional latissimus dorsi transfer (LDT) in patients with an active external rotation deficit (ERD) would restore external rotation (ER) with concomitant deterioration in internal rotation.
Methods: In our cohort study, 26 RCA patients with an active ERD (ie, positive lag sign and maximum active ER of 0°) underwent RSA between September 2007 and February 2015; LDT was completed in 13 of these patients. In addition, 88 control patients without ERD who underwent only RSA were identified.
Background/aim: The JAMAR-Dynamometer and the Martin-Vigorimeter are frequently used tools in a hand surgeon's daily routine. This survey is primarily concerned with the establishment of valid conversion factors for measured values of both instruments, as well as the investigation of influence of anatomical characteristics and age and sex on maximal measured grip strength.
Patients And Methods: We registered anamnestic data and specific anatomical conditions in 339 patients, maximal grip strength was measured using all notches of both instruments.
Introduction: Although a plenty of studies exist assessing the strength of ligamentous fixation techniques using porcine flexor digitorum profundus tendons as graft substitutes for human hamstring tendons, there is no biomechanical study comparing these two tendons. To interpret the results obtained with porcine flexor digitorum profundus tendons, knowledge of their biomechanical properties is essential. The purpose of this study was to compare the biomechanical properties of human hamstring tendons and porcine flexor digitorum profundus tendons.
View Article and Find Full Text PDFPurpose: In autologous osteochondral transplantation, the edges of the harvested plug are particularly susceptible to mechanical or thermal damage to the chondrocytes. We hypothesised that the applied harvesting device has an impact on chondrocyte vitality.
Methods: Both knees of five blackhead sheep (ten knees) underwent open osteochondral plug harvesting with three different circular harvesting devices (osteoarticular transfer system harvester [OATS; diameter 8 mm; Arthrex, Munich, Germany], diamond cutter [DC; diameter 8.
Arch Orthop Trauma Surg
November 2015
Introduction: Extracortical fixation techniques in anterior cruciate ligament reconstruction bear the risk of tunnel enlargement, while close-to-aperture fixations often show lower failure loads. The purpose for this study was to investigate the biomechanical benefits of a novel implant-free combination of an extra-cortical and close-to-aperture fixation.
Materials And Methods: Quadrupled human cadaveric semitendinosus tendons were fixed to 30 porcine tibiae with either a cannulated interference screw (I), an implant-free post-fixation (S), or a novel pull-press fixation (P).