Significance: The database for multipulse retinal damage thresholds for the laser safety standard (IEC 60825-1:2014) is confined, especially for elongated irradiation profiles. To ensure eye safety, retinal damage thresholds ( values) need to be determined.
Aim: This study aims to examine nanosecond multipulse scenarios.
Biomed Opt Express
December 2020
The data situation of laser-induced damage measurements after multiple-pulse irradiation in the ns-time regime is limited. Since the laser safety standard is based on damage experiments, it is crucial to determine damage thresholds. For a better understanding of the underlying damage mechanism after repetitive irradiation, we generate damage thresholds for pulse sequences up to Nā=ā20ā000 with 1.
View Article and Find Full Text PDFLasers with wavelengths in the visible and near infrared region, pose a potential hazard to vision as the radiation can be focused on the retina. The laser safety standard IEC 60825-1:2014 provides limits and evaluation methods to perform a classification for such systems. An important parameter is the retinal spot size which is described by the angular subtense of the apparent source.
View Article and Find Full Text PDF