Publications by authors named "Sean Mccafferty"

Self-amplifying RNA vaccines may induce equivalent or more potent immune responses at lower doses compared to non-replicating mRNA vaccines via amplified antigen expression. In this paper, we demonstrate that 1 μg of an LNP-formulated dual-antigen self-amplifying RNA vaccine (ZIP1642), encoding both the S-RBD and N antigen, elicits considerably higher neutralizing antibody titers against Wuhan-like Beta B.1.

View Article and Find Full Text PDF

: Evaluate potential corneal biomechanical changes following corneal crosslinking (CXL) by paired differential tonometry intraocular pressure (IOP) measurements with a Goldmann tonometer (GAT) prism and corneal compensating, correcting applanation tonometry surface (CATS) prism.: IOP was measured prospectively on 23 unique eyes undergoing CXL for keratoconus with a GAT using a standard flat GAT prism and a curved corneal error correcting CATS prism before treatment and at 2 weeks, 2 months and 6 months after treatment. Concurrent measurements of central corneal thickness (CCT) and corneal hysteresis (CH) were completed.

View Article and Find Full Text PDF

Purpose: Evaluate the correlation between statutory social distancing interventions and Covid-19 mortality independently in both the United States and Europe. The study is presented as a potential methodology to evaluate the effectiveness of statutory social distancing policy.

Patients And Methods: Twenty-seven states in the United States and, separately, 12 European countries were selected which had clearly defined and dated establishment of statewide or national mandates for social distancing measures from the Institute for Health Metrics and Evaluation (IHME) data.

View Article and Find Full Text PDF

Synthetic mRNAs are an appealing platform with multiple biomedical applications ranging from protein replacement therapy to vaccination. In comparison with conventional mRNA, synthetic self-amplifying mRNAs (sa-mRNAs) are gaining interest because of their higher and longer-lasting expression. However, sa-mRNAs also elicit an innate immune response, which may complicate their clinical application.

View Article and Find Full Text PDF

Purpose: To evaluate intraocular pressure (IOP) reduction measured by a Goldmann applanation tonometer (GAT) prism and a modified surface Goldmann (CATS) prism with the institution of a topical prostaglandin analog (PGA) or alternatively a topical beta blocker.

Design: Prospective, open-label, randomized, controlled, and reference device comparison.

Methods: Thirty-six (36) treatment naïve glaucoma patients (72 eyes) were randomized equally to treatment with latanoprost 0.

View Article and Find Full Text PDF

Purpose: Clinically evaluate intraocular pressure (IOP) measurements taken with a Goldmann applanation tonometer (GAT) prism and a modified surface Goldmann prism examining measurement differences correlated to central corneal thickness (CCT) and corneal hysteresis (CH) values.

Design: Prospective, open-label, randomised, controlled, multicentre reference device accuracy analysis.

Methods: A GAT and a modified surface GAT prism measured IOP on 243 unique eyes.

View Article and Find Full Text PDF

Purpose: To clinically evaluate a modified surface Goldmann applanation tomometer (GAT) prism for intraocular pressure (IOP) accuracy, repeatability, and safety.

Design: Prospective, open-label, randomized, controlled, multicenter reference device reliability and validity analysis.

Methods: A GAT and a modified surface GAT prism measured IOP on 173 unique eyes.

View Article and Find Full Text PDF

Purpose: The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism.

Methods: The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.

View Article and Find Full Text PDF

Introduction: Piperacillin/tazobactam is a commonly used antibiotic for the empirical treatment of severe diabetic foot infections. One of the most feared complications of this drug is the development of pancytopenia. The aim of this study was to determine whether the use of piperacillin/tazobactam caused any hematological changes in patients admitted with severe diabetes-related foot infections from a specialist multidisciplinary foot clinic.

View Article and Find Full Text PDF

Background: Compare Goldmann applanation tonometer (GAT) prism and correcting applanation tonometry surface (CATS) prism to intracameral intraocular pressure (IOP), in vivo and in vitro.

Methods: Pressure transducer intracameral IOP was measured on fifty-eight (58) eyes undergoing cataract surgery and the IOP was modulated manometrically to 10, 20, and 40 mmHg. Simultaneously, IOP was measured using a Perkins tonometer with a standard GAT prism and a CATS prism at each of the intracameral pressures.

View Article and Find Full Text PDF

Background: Goldmann applanation tonometry (GAT) error relative to intracameral intraocular pressure (IOP) has not been examined comparatively in both human cadaver eyes and in live human eyes. Futhermore, correlations to biomechanical corneal properties and positional changes have not been examined directly to intracameral IOP and GAT IOP.

Methods: Intracameral IOP was measured via pressure transducer on fifty-eight (58) eyes undergoing cataract surgery and the IOP was modulated manometrically on each patient alternately to 10, 20, and 40 mmHg.

View Article and Find Full Text PDF

Purpose: Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics.

Methods: A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness, stiffness, curvature, and tear film adhesion force. A comparative clinical study of 109 eyes measured IOP with CATS and Goldmann prisms.

View Article and Find Full Text PDF

Background: Define the effectiveness of a topical non-steroidal anti-inflammatory drug (NSAID) added to topical steroid use after uncomplicated phacoemulsification for the prevention of pseudophakic cystoid macular edema (PCME) using a prospective, randomized, double-masked, placebo-controlled clinical study.

Methods: Eyes (1000) were randomized to placebo (497) or nepafenac 0.3% (503) used once daily, post-operatively for 5 weeks at two ophthalmology clinics.

View Article and Find Full Text PDF

Purpose: We evaluate solutions for an applanating surface modification to the Goldmann tonometer prism, which substantially negates the errors due to patient variability in biomechanics.

Methods: A modified Goldmann or correcting applanation tonometry surface (CATS) prism is presented which was optimized to minimize the intraocular pressure (IOP) error due to corneal thickness, stiffness, curvature, and tear film. Mathematical modeling with finite element analysis (FEA) and manometric IOP referenced cadaver eyes were used to optimize and validate the design.

View Article and Find Full Text PDF

Purpose: Present an analysis methodology for developing and evaluating accommodating intraocular lenses incorporating a deformable interface.

Methods: The next generation design of extruded gel interface intraocular lens is presented. A prototype based upon similar previously in vivo proven design was tested with measurements of actuation force, lens power, interface contour, optical transfer function, and visual Strehl ratio.

View Article and Find Full Text PDF

Purpose: We examined corneal surface response to an isolated thermal load.

Methods: Cadaveric porcine eyes were pressurized and stabilized for processing and imaging. A carbon dioxide (CO2) laser (1.

View Article and Find Full Text PDF

Purpose: To examine the interaction between the excimer laser and residual tissue.

Methods: Ten cadaveric porcine eyes with exposed corneal stroma and plastic test spheres underwent uniform 6-mm ablation with a scanning excimer laser. Corneal profilometry of the central 3 mm was measured with submicrometer resolution optical interferometry, before and after uniform excimer ablation.

View Article and Find Full Text PDF