HyperArc is a preferred technique for treating brain metastases, employing a single isocenter for multiple lesions. Geometrical isocentricity in the TrueBeam linear accelerator with HyperArc is crucial. We evaluated machine performance checks (MPCs) as an alternative to the Winston-Lutz (WL) test to verify the treatment isocenter.
View Article and Find Full Text PDFThis study aimed to fabricate a heterogeneous phantom replicating the commercial Rando phantom by mixing plaster powder and polylactic acid (PLA) powder. Producing a heterogeneous phantom using Plaster and PLA is cheaper because it can be easily obtained in the commercial market. Additionally, patient-specific Quality Assurance can be easily performed because the phantom can be produced based on the patient's CT image.
View Article and Find Full Text PDFThe bladder is subject to filling variation, which poses a challenge to radiotherapy (RT) delivery. We aimed to assess feasibility and clinical outcomes in patients with bladder cancer treated with adaptive RT (ART) using individualized plan libraries. We retrospectively analyzed 19 patients who underwent RT for muscle-invasive bladder cancer (MIBC) in 2015-2021.
View Article and Find Full Text PDFHealthcare (Basel)
September 2022
The use of IT applications for patients undergoing radiotherapy is limited. This study aimed to develop an integrated system for communication between patients and radiation oncologists using IT technology and report the first test results for the system "Assisted Radiation Oncology Mobile Application" (AROMA). This system consisted of a manager program, a server running on a PC, and a mobile application on a smartphone.
View Article and Find Full Text PDFWe aimed to determine the optimal pressure of continuous positive airway pressure (CPAP) for radiotherapy (RT) through changes in the dosimetric parameters and lung volume according to pressure. Patients with locally advanced lung cancer, who underwent CPAP during computed tomography (CT) simulation, were included. The air pressure was raised in five steps of 4, 7, 10, 14, and 17 cmH2O and a CT scan was performed at the baseline and at each pressure step, accompanied by contouring and RT planning.
View Article and Find Full Text PDFExternal beam radiotherapy is effective for stage I orbital mucosa-associated lymphoid tissue lymphoma (MALToma). Hence, very-low-dose radiotherapy is increasingly being investigated. We conducted a single-center prospective phase II trial to evaluate the effectiveness of very-low-dose radiotherapy of 4 Gy (2 Gy × 2 fractions) in pathologically confirmed stage I orbital MALToma.
View Article and Find Full Text PDFVarious applications of head-tilting techniques in whole-brain radiotherapy (WBRT) have been introduced. However, a study on the setup uncertainties and margins in head-tilting techniques has not been reported. This study evaluated the setup uncertainties and determined the appropriate planning target volume (PTV) margins for patients treated in the head-tilted supine (ht-SP) and conventional supine position (c-SP) in WBRT.
View Article and Find Full Text PDFBackground: Neoadjuvant chemoradiotherapy (nCRT) followed by surgery is a standard treatment modality for locally-advanced esophageal cancer. However, patients who achieve clinical complete response (cCR) after nCRT have been reported to have better prognosis. Further, the role of surgery in these patients is controversial.
View Article and Find Full Text PDFBackgruound: This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device. Portal dosimetry is extensively used for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT).
Methods: The study includes 29 patients who underwent IMRT on a Novalis-Tx linear accelerator (Varian Medical System and BrainLAB) between June 2019 and March 2021.
Purpose: Concurrent chemoradiotherapy (CCRT) is recommended as the standard treatment for locally advanced cervical cancer (LACC). However, the synergistic effect of hyperthermia (HT) with CCRT remains unclear. Therefore, we performed a meta-analysis to evaluate the effect of HT with CCRT on LACC patients.
View Article and Find Full Text PDFThe objective of this study was to analyze the difference in residual setup errors between 6D ExacTrac and 3D cone-beam computed tomography (CBCT) image-guided systems in spinal stereotactic body radiation therapy (SBRT). We investigated 76 patients with spinal tumors who received SBRT using Novalis Tx at our institution between January 2013 and September 2020. A Vac-lok (EZ-FIX®, Arlico Medical Company, South Korea) fixture and an assistive device, based on the region involved, were used to immobilize patients and to increase the inter-fractional setup reproducibility.
View Article and Find Full Text PDFPurpose: Coplanar arcs are used with limited arc range to prevent direct beam entrance through the lens, which is challenging for satisfactory planning of hippocampal sparing in whole brain radiotherapy (HS-WBRT) with VMAT. We evaluated the dosimetric impact of applying a head-tilting technique during VMAT, which allows unrestricted use of the arc range.
Methods And Materials: Twenty patients with multiple brain metastases who had received two computed tomography (CT)-simulation sessions between January 2016 and December 2018 were included.
This study aimed to prospectively investigate the association between body weight (ΔBW) or body volume variations (ΔBV) and inter- or intra-fractional variations (Δ(inter) or Δ(intra)) in patients with head and neck cancer (HNC) undergoing radiotherapy (RT). This study enrolled patients with HNC from December 2015 to December 2017. All patients underwent curative intensity-modulated RT (IMRT) either as definitive or adjuvant treatment.
View Article and Find Full Text PDFRespiratory-gated radiotherapy is one of the most effective approaches to minimise radiation dose delivery to normal tissue and maximise delivery to tumours under patient's motion caused by respiration. We propose a respiration guiding system based on real-time position management with suitable gating window for respiratory-gated radiotherapy applied to liver cancer. Between August 2016 and February 2018, 52 patients with liver cancer received training in real-time position management and respiration guiding.
View Article and Find Full Text PDFThis study evaluated the feasibility of utilizing a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Contoured left and right head phantoms were converted from DICOM to STL format. Fused deposition modeling (FDM) was used to construct an anthropomorphic patient-specific head phantom with a 3D printer.
View Article and Find Full Text PDFThe objective of this study was to evaluate the setup discrepancy between BrainLAB 6 degree-of-freedom (6D) ExacTrac and cone-beam computed tomography (CBCT) used with the imaging guidance system Novalis Tx for intracranial stereotactic radiosurgery. We included 107 consecutive patients for whom white stereotactic head frame masks (R408; Clarity Medical Products, Newark, OH) were used to fix the head during intracranial stereotactic radiosurgery, between August 2012 and July 2016. The patients were immobilized in the same state for both the verification image using 6D ExacTrac and online 3D CBCT.
View Article and Find Full Text PDFA three-dimensional (3D)-printed customized bolus (3D bolus) can be used for radiotherapy application to irregular surfaces. However, bolus fabrication based on computed tomography (CT) scans is complicated and also delivers unwanted irradiation. Consequently, we fabricated a bolus using a 3D scanner and evaluated its efficacy.
View Article and Find Full Text PDFRespiratory-gated radiation therapy (RGRT) is used to minimize the radiation dose to normal tissue in lung-cancer patients. Although determining the gating window in the respiratory phase of patients is important in RGRT, it is not easy. Our aim was to determine the optimal gating window when using a visible guiding system for RGRT.
View Article and Find Full Text PDFThis study evaluated the setup uncertainties for brain sites when using BrainLAB's ExacTrac X-ray 6D system for daily pretreatment to determine the optimal planning target volume (PTV) margin. Between August 2012 and April 2015, 28 patients with brain tumors were treated by daily image-guided radiotherapy using the BrainLAB ExacTrac 6D image guidance system of the Novalis-Tx linear accelerator. DUONTM (Orfit Industries, Wijnegem, Belgium) masks were used to fix the head.
View Article and Find Full Text PDFPurpose: This treatment planning study was undertaken to evaluate the impact of beam angle configuration of intensity-modulated radiotherapy (IMRT) on the dose of the normal liver in hepatocellular carcinoma (HCC).
Materials And Methods: The computed tomography datasets of 25 patients treated with IMRT for HCC were selected. Two IMRT plans using five beams were made in each patient; beams with equidistance of 72° (Plan I), and beams with a 30° angle of separation entering the body near the tumor (Plan II).