Publications by authors named "Sciacovelli L"

Point-of-care testing (POCT) is becoming an increasingly popular way to perform laboratory tests closer to the patient. This option has several recognized advantages, such as accessibility, portability, speed, convenience, ease of use, ever-growing test panels, lower cumulative healthcare costs when used within appropriate clinical pathways, better patient empowerment and engagement, and reduction of certain pre-analytical errors, especially those related to specimen transportation. On the other hand, POCT also poses some limitations and risks, namely the risk of lower accuracy and reliability compared to traditional laboratory tests, quality control and connectivity issues, high dependence on operators (with varying levels of expertise or training), challenges related to patient data management, higher costs per individual test, regulatory and compliance issues such as the need for appropriate validation prior to clinical use (especially for rapid diagnostic tests; RDTs), as well as additional preanalytical sources of error that may remain undetected in this type of testing, which is usually based on whole blood samples (i.

View Article and Find Full Text PDF

Objectives: Healthcare has a considerable environmental impact, yet it has been largely overlooked. Clinical laboratories, in particular, consume significantly more energy and water per unit area compared to standard office buildings. It is crucial to raise awareness among laboratories about the significance of embracing eco-friendly practices.

View Article and Find Full Text PDF

Objective: As of today, healthcare systems worldwide face severe challenges that undermine their sustainability. The value-based healthcare (VBHC) approach has been proposed as a strategic and methodological framework to ensure the delivery of the best patient outcomes with economic efficiency. Through the illustrative example of B-type natriuretic peptide (BNP) and N-terminal proBNP (NT-proBNP) for heart failure (HF) patient management in the context of the Italian National Healthcare system, this article explores the role that in vitro diagnostics (IVDs) can play in enabling value-based care models.

View Article and Find Full Text PDF

In the last few decades, quality in laboratory medicine has evolved in concert with the transformation and the changes (technological, scientific and organizational) in this sector. Laboratory professionals have faced great challenges, at times being overwhelmed, yet also involved in this progress. Worldwide, laboratory professionals and scientific societies involved in laboratory medicine have raised awareness concerning the need to identify new quality assurance tools that are effective in reducing the error rate and enhancing patient safety, in addition to Internal Quality Control (IQC) procedures and the participation in the External Quality Assessment Schemes (EQAS).

View Article and Find Full Text PDF

Introduction: Despite the important diagnostic role of peripheral blood morphology, cell classification is subjective. Automated image-processing systems (AIS) provide more accurate and objective morphological evaluation. The aims of this multicenter study were the evaluation of the intra and inter-laboratory variation between different AIS in cell pre-classification and after reclassification, compared with manual optical microscopy, the reference method.

View Article and Find Full Text PDF

Major adverse cardiovascular events are frequently observed in patients undergoing major non-cardiac surgery during the peri-operative period. At this time, the possibility to predict cardiovascular events remains limited, despite the introduction of several algorithms to calculate the risk of adverse events, mainly death and major adverse cardiovascular events (MACE) based on the clinical history, risk factors (sex, age, lipid profile, serum creatinine) and non-invasive cardiac exams (electrocardiogram, echocardiogram, stress tests). The cardiac-specific biomarkers natriuretic peptides (NPs) and cardiac troponins (cTn) have been proposed as additional tools for risk prediction in the peri-operative period, particularly for the identification of myocardial injury in patients undergoing major non-cardiac surgery.

View Article and Find Full Text PDF

Serial measurements of cardiac troponin are recommended by international guidelines to diagnose myocardial infarction (MI) since 2000. However, some relevant differences exist between the three different international guidelines published between 2020 and 2021 for the management of patients with chest pain and no ST-segment elevation. In particular, there is no agreement on the cut-offs or absolute change values to diagnose non-ST-segment elevation MI (NSTEMI).

View Article and Find Full Text PDF

Objectives: Numerous analytical systems, rapidly made available on the market throughout the SARS-CoV-2 pandemic, aim to detect COVID-19, and to continuously update and improve the same systems. Medical laboratory professionals have also developed in-house analytical procedures in order to satisfy the enormous volume of requests for tests. These developments have highlighted the need control the analytical procedures used in order to guarantee patient safety.

View Article and Find Full Text PDF

Objectives: SARS-CoV-2 serology presents an important role in several aspects of COVID-19 pandemic. Immunoassays performances have to be accurately evaluated and correlated with neutralizing antibodies. We investigated the analytical and clinical performances of a SARS-CoV-2 RBD IgG assay, automated on a high throughput platform, and the correlation of the antibodies (Ab) levels with the plaque reduction neutralization (PRNT) Ab titers.

View Article and Find Full Text PDF

European Union (EU) Directive 2013/55/EC (The Recognition of Professional Qualifications) allows Member States to decide on a common set of minimum knowledge, skills and competences that are needed to pursue a given profession through a Common Training Framework. To be adopted the framework must combine the knowledge, skills and competences of at least one third of the Member States. Professionals who have gained their qualifications under a Common Training Framework will be able to have these recognised automatically within the Union.

View Article and Find Full Text PDF

Background: Reliable high-throughput serological assays for SARS-CoV-2 antibodies are urgently needed for the effective containment of the COVID-19 pandemic, as it is of crucial importance to understand the strength and duration of immunity after infection, and to make informed decisions concerning the activation or discontinuation of physical distancing restrictions.

Methods: In 184 serum samples from 130 COVID-19 patients and 54 SARS-CoV-2 negative subjects, the analytical and clinical performances of four commercially available chemiluminescent assays (Abbott SARS-Cov-2 IgG, Roche Elecsys anti-SARS-CoV-2, Ortho SARS-CoV-2 total and IgG) and one enzyme-linked immunosorbent assay (Diesse ENZY-WELL SARS-CoV-2 IgG) were evaluated and compared with the neutralization activity achieved using the plaque reduction neutralization test (PRNT).

Findings: Precision results ranged from 0.

View Article and Find Full Text PDF

Introduction: The factor VIII (FVIII)-mimetic bispecific monoclonal antibody, emicizumab, previously approved for prophylaxis in haemophilia A with inhibitors, has been recently licensed in several countries also in patients with severe haemophilia A (PWSHA) without inhibitors. The introduction of this innovative agent requires the development of specific pathways at Haemophilia Treatment Centres (HTC), particularly regarding laboratory testing and treatment of breakthrough bleeds and invasive procedures/surgeries, even more critical when patients are managed by non-specialist professionals. Limited literature data and clinical experience in PWSHA without inhibitors on emicizumab are currently available.

View Article and Find Full Text PDF

In recent years, the formulation of some immunoassays with high-sensitivity analytical performance allowed the accurate measurement of cardiac troponin I (cTnI) and T (cTnT) levels in reference subjects. Several studies have demonstrated the association between the risk of major cardiovascular events and cardiac troponin concentrations even for biomarker values within the reference intervals. High-sensitivity cTnI and cTnT methods (hs-cTn) enable to monitor myocardial renewal and remodelling, and to promptly identify patients at highest risk ofheart failure.

View Article and Find Full Text PDF

Background: The evaluation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific antibody (Ab) assay performances is of the utmost importance in establishing and monitoring virus spread in the community. In this study focusing on IgG antibodies, we compare reliability of three chemiluminescent (CLIA) and two enzyme linked immunosorbent (ELISA) assays.

Methods: Sera from a total of 271 subjects, including 64 reverse transcription-polymerase chain reaction (RT-PCR) confirmed SARS-CoV-2 patients were tested for specific Ab using Maglumi (Snibe), Liaison (Diasorin), iFlash (Yhlo), Euroimmun (Medizinische Labordiagnostika AG) and Wantai (Wantai Biological Pharmacy) assays.

View Article and Find Full Text PDF

Important advances achieved in pharmacological cancer treatment have led progressively to a reduction in mortality from many forms of cancer, and increasing numbers of previously incurable patients can now hope to become cancer-free. Yet, to achieve these improved outcomes a high price has been paid in terms of untoward side effects associated with treatment, cardio-toxicity in particular. Several recent studies have reported that cardiac troponin assay using high-sensitivity methods (hs-cTn) can enable the early detection of myocardial injury related to chemotherapy or abuse of drugs that are potentially cardiotoxic.

View Article and Find Full Text PDF

Validation studies of serological antibody tests must be properly designed for clinical, epidemiological and Public Health objectives such as confirmation of suspected COVID-19 cases, certification of seroconversion after infection, and epidemiological surveillance. We evaluated the kinetics of IgM, IgA and IgG SARS-CoV-2 antibodies in COVID-19 patients with confirmed (rRT-PCR) infection. We found that the IgA response appears and grows early, peaks at week 3, and it is stronger and more persistent than the IgM response.

View Article and Find Full Text PDF

Objectives: The aim of this study was to assess the commutability of three external quality assessment (EQA) materials for point-of-care (POC) glucose testing using two approaches, to identify suitable EQA materials to evaluate and monitor the quality of POC testing.

Methods: Commercial control materials (CCMs), pooled human serum samples (PHSs), and homemade human whole-blood samples (HWBs) were measured along with 33 individual clinical samples using five POC instruments and a Hitachi 7600 analyzer. Data were analyzed by Deming regression analysis with a 95% prediction interval as described in Clinical and Laboratory Standards Institute (CLSI) EP30-A, and by difference in bias analysis as described by the International Federation of Clinical Chemistry (IFCC) Working Group on Commutability.

View Article and Find Full Text PDF

Background Coronavirus disease 2019, abbreviated to COVID-19, represents an emerging health threat worldwide as, after initial reports in China, it has continued to spread rapidly. The clinical spectrum of the disease varies from mild to severe acute respiratory distress syndrome (ARDS). Moreover, many patients can be asymptomatic, thus increasing the uncertainty of the diagnostic work-up.

View Article and Find Full Text PDF

Aims Of The Study: To evaluate the state-of-the-art of 14 specific proteins measurement; to evaluate the laboratories' performance and the degree of harmonization in reporting results of participants in the External Quality Assessment Program of the Centre of Biomedical Research (CRB).

Methods: Overall and system-related inter-laboratory analytical variability (mean CVs%) and between-system differences (mean bias%) were evaluated from data of six EQA cycles 2013-2018. Moreover, we evaluated the analytical performance of participants as well as the units used to express proteins results.

View Article and Find Full Text PDF

Objectives: Standardized criteria guaranteeing harmonized interpretation among morphologists in the provision of morphology results represent an important tool to be adopted for risk management and patient safety. Aim of this work is to assess agreement among morphologists in the microscopic evaluation of the peripheral blood smear.

Methods: 17 morphologists participating in the external quality assessment (EQA) program individually evaluated the blood smear and recorded the results using a personal username and password.

View Article and Find Full Text PDF