Viral disinfection is important for medical facilities, the food industry, and the veterinary field, especially in terms of controlling virus outbreaks. Therefore, standardized methods and activity levels are available for these areas. Usually, disinfectants used in these areas are characterized by their activity against test organisms (i.

View Article and Find Full Text PDF

In Germany, recommendations on infection prevention and control of current virus outbreaks are given as communications by the Association for Applied Hygiene e.V. (VAH) together with the joint Disinfectant Commission of the German Association for the Control of Virus Diseases e.

View Article and Find Full Text PDF

Background: The approval of ethanol by the Biocidal Products Regulation has been under evaluation since 2007. This follows concern over alcohol uptake from ethanol-based hand rubs (EBHR). If ethanol is classified as carcinogenic, mutagenic, or reprotoxic by the European Chemicals Agency (ECHA), then this would affect infection prevention and control practices.

View Article and Find Full Text PDF

Background: One possible transmission route for nosocomial pathogens is contaminated medical devices. Formation of biofilms can exacerbate the problem. We report on a carbapenemase-producing Klebsiella pneumoniae that had caused an outbreak linked to contaminated duodenoscopes.

View Article and Find Full Text PDF

Background: A sporicidal surface disinfection is recommended both for the outbreak and the endemic setting but a comparative evaluation on the efficacy of 'sporicidal' surface disinfectants using suspension tests and 4-field tests has not been performed.

Aim: To determine the efficacy of five 'sporicidal' surface disinfectants (three ready-to-use wipes (A, B, E), two concentrates (C, D) based on peroxides or aldehydes against C. difficile spores.

View Article and Find Full Text PDF

The Global Polio Eradication initiative has the goal to eradicate poliomyelitis worldwide. This means that poliomyelitisvirus type 1 strain LSc 2ab (PV-1) can no longer be used for the evaluation of virucidal activity of chemical disinfectants. This study evaluated murine parvovirus ATCC VR 1346 (minute virus of mice) as suitable surrogate for PV-1 when testing virucidal activity of biocides in instrument and surface disinfectants.

View Article and Find Full Text PDF

Disinfection measures have become more important as a result of the COVID-19 pandemic in Germany. The increased need for disinfectants at the beginning of the pandemic required temporary legal regulations in order to provide a sufficient quantity of products for the necessary disinfection in the medical sector on the one hand and for the additional demand in the population on the other. For this purpose, the Federal Institute for Drugs and Medical Devices (BfArM) and the Federal Institute for Occupational Safety and Health (BAuA) issued a general ruling, which is explained in more detail in this article.

View Article and Find Full Text PDF

When facing an emerging virus outbreak such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), a quick reaction time is key to control the spread. It takes time to develop antivirals and vaccines, and implement vaccination campaigns. Therefore, preventive measures such as rapid isolation of cases and identification and early quarantine of cases' close contacts-as well as masks, physical distancing, hand hygiene, surface disinfection and air control-are crucial to reduce the risk of transmission.

View Article and Find Full Text PDF

Exploratory field analyses of the inactivation capacity of disinfectants on contaminated personal protective equipment (PPE) are required to select a suitable surrogate for biohazardous agents like spores of . The objectives of our study were (1) the determination of an appropriate surrogate for the inactivation of spores of with peracetic acid (PAA), and (2) application of optimized inactivation conditions for an effective decontamination of PPE with PAA under field conditions. For inactivation studies, spores from different strains and spores were fixed by air drying on carriers prepared from PPE fabric.

View Article and Find Full Text PDF

Aims: The work aimed at developing and evaluating practically relevant methods for testing of disinfectants on contaminated personal protective equipment (PPE).

Methods And Results: Carriers were prepared from PPE fabrics and contaminated with Bacillus subtilis spores. Peracetic acid (PAA) was applied as a suitable disinfectant.

View Article and Find Full Text PDF
[Not Available].

Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz

March 2017

View Article and Find Full Text PDF

Bacteria live primarily in microbial communities (biofilms), where they exhibit considerably higher biocide tolerance than their planktonic counterparts. Current standardized efficacy testing protocols of disinfectants, however, employ predominantly planktonic bacteria. In order to test the efficacy of biocides on biofilms in a standardized manner, a new assay was developed and optimized for easy-handling, quickness, low running costs, and above all-repeatability.

View Article and Find Full Text PDF
[Not Available].

Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz

April 2016

View Article and Find Full Text PDF

Formaldehyde (FA) fixation of infectious samples is a well-established protocol in diagnostic electron microscopy of viruses. However, published experimental data that demonstrate virus inactivation by these fixation procedures are lacking. Usually, fixation is performed immediately before the sample preparation for microscopy.

View Article and Find Full Text PDF

In order to protect human health against communicable diseases, the German Protection against Infection Act (IfSG) requires the use of officially approved products and methods for officially ordered disinfection, disinfestation (control of arthropods) as well as measures for the management of vertebrate pests that spread pathogens. Official approval is granted by registration in lists published by the responsible federal health authorities and only for products and methods that have been tested and found to be sufficiently effective and do not have an unacceptable impact on health and the environment (§ 18 IfSG). It is not compulsory for manufacturers to have their products and methods listed in accordance with § 18 IfSG.

View Article and Find Full Text PDF

Surface disinfectants are part of broader preventive strategies preventing the transmission of bacteria, fungi and viruses in medical institutions. To evaluate their virucidal efficacy, these products must be tested with appropriate model viruses with different physico-chemical properties under conditions representing practical application in hospitals. The aim of this study was to evaluate a quantitative carrier assay.

View Article and Find Full Text PDF
[Hospital hygiene and infection prevention].

Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz

October 2007

View Article and Find Full Text PDF

Background: Inanimate surfaces have often been described as the source for outbreaks of nosocomial infections. The aim of this review is to summarize data on the persistence of different nosocomial pathogens on inanimate surfaces.

Methods: The literature was systematically reviewed in MedLine without language restrictions.

View Article and Find Full Text PDF

We analysed the sporicidal effect of different concentrations of aqueous and alcoholic peracetic acid (PAA) solutions on anthrax spores in suspension and germ carrier tests. In activation of anthrax spores in suspension assays was achieved in less than 2 min using 1% PAA solution and in less than 3 min using 0.5% PAA solution, respectively.

View Article and Find Full Text PDF

The authors' studies on the heat resistance of microorganisms and the superheating of steam (Spicher et al., Zbl. Hyg.

View Article and Find Full Text PDF