Background: For positron emission tomography (PET) kinetic modelling, an accurate determination of the arterial input function is required. In this study, a blood sampling system was developed and tested using different radiotracers in rats.

Methods: The detector consists of pairs of lutetium yttrium oxyorthosilicate (LYSO) detectors, photomultiplier tubes and lead shield assembled within a steel casing working in coincidence mode.

View Article and Find Full Text PDF

Two methods to compensate the gain drift of low level gamma-ray spectrometers are compared. For a period of 4 years, source injection and pulser method have been applied in parallel. The long term stability of a reference peak, injected by a precision pulser, has been validated by periodical source injection to sustain the energy calibration.

View Article and Find Full Text PDF

The sensitivity of a portal monitoring system has been improved by introducing speed dependent integration time in the data processing of the count rate signal. Characterization and first tests have been performed using a pneumatically driven (137)Cs point source, before deploying the system to a test point at a railway junction near Vienna. At 14m/s the MDA could be reduced by a factor of two and at 28m/s by a factor of three compared to a fixed integration time of 1s, whereas high sensitivity at low speed remained unaffected.

View Article and Find Full Text PDF

The active veto shielding of a low-level gamma spectrometer has been optimized to reduce the background in the interval 20-2700 keV by a factor of nine. The signal to noise ratio was increased, due to the reduction of electromagnetic interference coming from the power line, by using an uninterruptible power supply and specially designed line filters. The overall performance of the veto shielding was improved by using time spectroscopy to find the optimum time duration for the coincidence window.

View Article and Find Full Text PDF

The radionuclide laboratory at the Austrian Research Centers Seibersdorf (ATL03) was installed to support the international monitoring system for verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT and Text of the establishment of a Preparatory Commission for the Comprehensive Test-Ban-Treaty Organization, 1996). Therefore, the background of a high-purity germanium detection system has been reduced by developing a high sophisticated active and passive detector shielding. The entire system is encapsulated in an iron-castle and placed into a fall-out shelter.