Laser-plasma accelerators (LPAs) can deliver pico- to nanosecond long proton bunches with ≳100 nC of charge dispersed over a broad energy spectrum. Increasing the repetition rates of today's LPAs is a necessity for their practical application. This, however, creates a need for real-time proton bunch diagnostics.
View Article and Find Full Text PDFThe recently observed FLASH effect describes the observation of normal tissue protection by ultra-high dose rates (UHDR), or dose delivery in a fraction of a second, at similar tumor-killing efficacy of conventional dose delivery and promises great benefits for radiotherapy patients. Dedicated studies are now necessary to define a robust set of dose application parameters for FLASH radiotherapy and to identify underlying mechanisms. These studies require particle accelerators with variable temporal dose application characteristics for numerous radiation qualities, equipped for preclinical radiobiological research.
View Article and Find Full Text PDFLaser plasma-based accelerators (LPAs) of protons can contribute to research of ultra-high dose rate radiobiology as they provide pulse dose rates unprecedented at medical proton sources. Yet, LPAs pose challenges regarding precise and accurate dosimetry due to the high pulse dose rates, but also due to the sources' lower spectral stability and pulsed operation mode. Formodels, further challenges arise from the necessary small field dosimetry for volumetric dose distributions.
View Article and Find Full Text PDFLaser plasma-based particle accelerators attract great interest in fields where conventional accelerators reach limits based on size, cost or beam parameters. Despite the fact that particle in cell simulations have predicted several advantageous ion acceleration schemes, laser accelerators have not yet reached their full potential in producing simultaneous high-radiation doses at high particle energies. The most stringent limitation is the lack of a suitable high-repetition rate target that also provides a high degree of control of the plasma conditions required to access these advanced regimes.
View Article and Find Full Text PDFWe present a method extending scanning third-order correlator temporal pulse evolution measurement capabilities of high power short pulse lasers to spectral sensitivity within the spectral range exploited by typical chirped pulse amplification systems. Modelling of the spectral response achieved by angle tuning of the third harmonic generating crystal is applied and experimentally validated. Exemplary measurements of spectrally resolved pulse contrast of a Petawatt laser frontend illustrate the importance of full bandwidth coverage for the interpretation of relativistic laser target interaction in particular for the case of solid targets.
View Article and Find Full Text PDFLaser-driven ion sources are a rapidly developing technology producing high energy, high peak current beams. Their suitability for applications, such as compact medical accelerators, motivates development of robust acceleration schemes using widely available repetitive ultraintense femtosecond lasers. These applications not only require high beam energy, but also place demanding requirements on the source stability and controllability.
View Article and Find Full Text PDFBackground: Bimagrumab is a human monoclonal antibody binding to the activin type II receptor with therapeutic potential in conditions of muscle wasting and obesity. This phase I study evaluated the pharmacokinetics (PK), pharmacodynamics (PD), and safety of various dose regimens of bimagrumab and routes of administration in healthy older adults.
Methods: This was a randomized, double-blind, placebo-controlled, parallel-arm, multiple-dose study in older adult men and women (aged ≥ 70 years, body mass index [BMI] 18-34 kg/m) with stable health and diet.
Application experiments with laser plasma-based accelerators (LPA) for protons have to cope with the inherent fluctuations of the proton source. This creates a demand for non-destructive and online spectral characterization of the proton pulses, which are for application experiments mostly spectrally filtered and transported by a beamline. Here, we present a scintillator-based time-of-flight (ToF) beam monitoring system (BMS) for the recording of single-pulse proton energy spectra.
View Article and Find Full Text PDFDue to the non-linear nature of relativistic laser induced plasma processes, the development of laser-plasma accelerators requires precise numerical modeling. Especially high intensity laser-solid interactions are sensitive to the temporal laser rising edge and the predictive capability of simulations suffers from incomplete information on the plasma state at the onset of the relativistic interaction. Experimental diagnostics utilizing ultra-fast optical backlighters can help to ease this challenge by providing temporally resolved inside into the plasma density evolution.
View Article and Find Full Text PDFWe report the development of a multipurpose differential x-ray calorimeter with a broad energy bandwidth. The absorber architecture is combined with a Bayesian unfolding algorithm to unfold high energy x-ray spectra generated in high-intensity laser-matter interactions. Particularly, we show how to extract absolute energy spectra and how our unfolding algorithm can reconstruct features not included in the initial guess.
View Article and Find Full Text PDFJ Synchrotron Radiat
September 2021
The European XFEL delivers up to 27000 intense (>10 photons) pulses per second, of ultrashort (≤50 fs) and transversely coherent X-ray radiation, at a maximum repetition rate of 4.5 MHz. Its unique X-ray beam parameters enable groundbreaking experiments in matter at extreme conditions at the High Energy Density (HED) scientific instrument.
View Article and Find Full Text PDFWe reconstruct spectra of secondary X-rays from a tunable 250-350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 × 7.5 × 15 cm), modular X-ray calorimeter made of alternating layers of absorbing materials and imaging plates.
View Article and Find Full Text PDFPlasma wakefield accelerators are capable of sustaining gigavolt-per-centimeter accelerating fields, surpassing the electric breakdown threshold in state-of-the-art accelerator modules by 3-4 orders of magnitude. Beam-driven wakefields offer particularly attractive conditions for the generation and acceleration of high-quality beams. However, this scheme relies on kilometer-scale accelerators.
View Article and Find Full Text PDFWe report on a compact diode-pumped, chirped pulse regenerative amplifier system with a pulse duration of 162 fs and an output pulse energy of 1 mJ before as well as 910 µJ after compression optimized for the probing of ultrafast relativistic laser-plasma processes. A chirped volume Bragg grating (CVBG) acts as a combined pulse stretcher/compressor representing a robust solution for a CPA laser system in the millijoule range. Yb:CaF is used as gain medium to support a large bandwidth of 16 nm (FWHM) when spectral gain shaping is applied.
View Article and Find Full Text PDFWe report on experimental investigations of proton acceleration from solid foils irradiated with PW-class laser-pulses, where highest proton cut-off energies were achieved for temporal pulse parameters that varied significantly from those of an ideally Fourier transform limited (FTL) pulse. Controlled spectral phase modulation of the driver laser by means of an acousto-optic programmable dispersive filter enabled us to manipulate the temporal shape of the last picoseconds around the main pulse and to study the effect on proton acceleration from thin foil targets. The results show that applying positive third order dispersion values to short pulses is favourable for proton acceleration and can lead to maximum energies of 70 MeV in target normal direction at 18 J laser energy for thin plastic foils, significantly enhancing the maximum energy compared to ideally compressed FTL pulses.
View Article and Find Full Text PDFAim: To determine the prevalence of inflammatory bowel disease (IBD) in patients with type 1 diabetes (T1D) and to characterise patients with both diseases.
Methods: Data of 65.147 patients with T1D ≤18 years of 379 centres in Germany and Austria participating in the DPV initiative were analysed.
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
View Article and Find Full Text PDFWe report observations of coherent optical transition radiation interferometry (COTRI) patterns generated by microbunched ∼200-MeV electrons as they emerge from a laser-driven plasma accelerator. The divergence of the microbunched portion of electrons, deduced by comparison to a COTRI model, is ∼9× smaller than the ∼3 mrad ensemble beam divergence, while the radius of the microbunched beam, obtained from COTR images on the same shot, is <3 μm. The combined results show that the microbunched distribution has estimated transverse normalized emittance ∼0.
View Article and Find Full Text PDFIntense laser-driven proton pulses, inherently broadband and highly divergent, pose a challenge to established beamline concepts on the path to application-adapted irradiation field formation, particularly for 3D. Here we experimentally show the successful implementation of a highly efficient (50% transmission) and tuneable dual pulsed solenoid setup to generate a homogeneous (laterally and in depth) volumetric dose distribution (cylindrical volume of 5 mm diameter and depth) at a single pulse dose of 0.7 Gy via multi-energy slice selection from the broad input spectrum.
View Article and Find Full Text PDFFemtosecond (fs) x-ray pulses are a key tool to study the structure and dynamics of matter on its natural length and time scale. To complement radio-frequency accelerator-based large-scale facilities, novel laser-based mechanisms hold promise for compact laboratory-scale x-ray sources. Laser-plasma driven undulator radiation in particular offers high peak-brightness, optically synchronized few-fs pulses reaching into the few-nanometer (nm) regime.
View Article and Find Full Text PDFWe report on a proton acceleration experiment in which high-intensity laser pulses with a wavelength of 0.4 μm and with varying temporal intensity contrast have been used to irradiate water droplets of 20 μm diameter. Such droplets are a reliable and easy-to-implement type of target for proton acceleration experiments with the potential to be used at very high repetition rates.
View Article and Find Full Text PDFGenes Chromosomes Cancer
February 2020
Tenosynovial giant cell tumors (TGCTs) are characterized by rearrangements of CSF1, thought to drive overexpression of macrophage colony-stimulating factor (CSF1), thereby promoting tumor growth and recruitment of non-neoplastic mononuclear and multinucleated inflammatory cells. While fusions to collagen promoters have been described, the mechanism of CSF1 overexpression has been unclear in a majority of cases. Two cohorts of TGCT were investigated for CSF1 rearrangements using fluorescence in situ hybridization (FISH) and either RNA-seq or DNA-seq with Sanger validation.
View Article and Find Full Text PDFPhilos Trans A Math Phys Eng Sci
August 2019
We present a conceptual design for a hybrid laser-driven plasma wakefield accelerator (LWFA) to beam-driven plasma wakefield accelerator (PWFA). In this set-up, the output beams from an LWFA stage are used as input beams of a new PWFA stage. In the PWFA stage, a new witness beam of largely increased quality can be produced and accelerated to higher energies.
View Article and Find Full Text PDFThe shape of a wave carries all information about the spatial and temporal structure of its source, given that the medium and its properties are known. Most modern imaging methods seek to utilize this nature of waves originating from Huygens' principle. We discuss the retrieval of the complete kinetic energy distribution from the acoustic trace that is recorded when a short ion bunch deposits its energy in water.
View Article and Find Full Text PDF