Objectives: Periprosthetic femoral fractures (PFFs) have a higher incidence with cementless stems. The highest incidence among various cementless stem types was observed with double-wedged stems. Short stems have been introduced as a bone-preserving alternative with a higher incidence of PFF in some studies.
View Article and Find Full Text PDFIntroduction: Studies using conventional radiographical signs and computerized tomography (CT) for retroversion of the acetabulum have reported a prevalence of up to 25%. The purpose of this study was to provide a detailed report on acetabular version, gender, age and side differences in a large cohort.
Materials And Methods: A total of 404 patients receiving a whole-body CT scan, aged between 16 and 40 years, have been included in the study.
Background and purpose - To date, there is not a single clinical or mechanical study directly comparing a cemented and a cementless version of the same stem. We investigated the load-to-failure force of a cementless and a cemented version of a double tapered stem. Material and methods - 10 femurs from 5 human cadaveric specimens, mean age 74 years (68-79) were extracted.
View Article and Find Full Text PDFIntroduction: Impingement of the prominent anterior inferior iliac spine (AIIS) against the femoral neck has recently been described as another type of impingement. The purpose of this study is to provide a distribution of AIIS types using the classification proposed by Hetsroni and thus report on the prevalence of prominent types.
Materials And Methods: A total of 400 patients were included in the study with an average age 27.
Arch Orthop Trauma Surg
October 2018
Introduction: The aim of the present study was to determine the incidence and type of complications during and after hip arthroscopy as well as the effect of the surgeon's learning curve on the occurrence of complications. We expect that the currently reported prevalence especially of minor complications is likely to be underreported in most retrospective series based on chart analysis.
Materials And Methods: The study included all consecutive patients who underwent hip arthroscopy between 2006 and 2014 at a minimum follow-up of 6 weeks starting with the first patient undergoing hip arthroscopy at the institution.
Background: In an earlier paper, it was shown that tailored magnetic resonance imaging (MRI) allows for reproducible analysis of the preserved knee joint structures after patellofemoral replacement (PFR).
Purposes: This pilot study investigates to what degree MRI could produce reliable assessment of the implant-bone interface of femoral and patellar components and rotational alignment following PFR.
Methods: MRI tailored for reduction of metallic artefacts was performed in seven patients who had undergone PFR.
Z Orthop Unfall
December 2013
Background: The treatment of hip instability in patients with Down syndrome is challenging. We have performed different pelvic osteotomies and corrections at the proximal femur for this indication. This retrospective study was conducted to evaluate the clinical and radiological outcome of each intervention.
View Article and Find Full Text PDFPurpose: Articular cartilage defects of the knee are a common condition for which several repair techniques have been described. The aim of the present study was to assess medium-term results of a one-step procedure using a cell-free collagen type I matrix.
Methods: Fifteen patients with articular cartilage defects of the knee were treated with an 11-mm-diameter cell-free collagen type 1 matrix implant.
BMC Musculoskelet Disord
February 2013
Background: Assessment of shoulder mobility is essential for diagnosis and clinical follow-up of shoulder diseases. Only a few highly sophisticated instruments for objective measurements of shoulder mobility are available. The recently introduced DynaPort MiniMod TriGyro ShoulderTest-System (DP) was validated earlier in laboratory trials.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
February 2014
Purpose: The present study was designed to evaluate the penetration of diclofenac sodium 4 % spray gel in synovial tissue, synovial fluid and blood plasma after topical application in subjects with joint effusions and planned total knee arthroplasty (TKA) due to osteoarthritis.
Methods: A total of 39 patients were randomised to two- or three-times daily application of diclofenac sodium 4 % spray gel to knees requiring surgery over a treatment period of 3 days. Within 8 h after the last application, TKA was conducted, and the diclofenac concentrations in synovial tissue, synovial fluid and blood plasma were measured by liquid chromatography.
Introduction: Synthol is a site enhancement oil used by bodybuilders to boost the cosmetic appearance of muscles. Here, we describe the case of a patient with severe side effects following repeated intramuscular injections of synthol in his right biceps muscle.
Case Presentation: A 29-year-old Middle Eastern male bodybuilder, following intramuscular injections of synthol five years ago, presented with painful pressure in his right upper arm.
The reconstruction of large bone defects after injury or tumor resection often requires the use of bone substitution. Artificial scaffolds based on synthetic biomaterials can overcome disadvantages of autologous bone grafts, like limited availability and donor side morbidity. Among them, scaffolds based on nanofibers offer great advantages.
View Article and Find Full Text PDFUltrasonography of the hip has gained wide acceptance as reliable method for diagnosing developmental hip dysplasia in infants. This blinded study was conducted to investigate the influence of two linear probes with different frequency on diagnostic accuracy and reproducibility. In 206 consecutive newborns, the bony roof angle (α-angle) and cartilage roof angle (β-angle) were assessed by three investigators according to Graf.
View Article and Find Full Text PDFPurpose: The aim of this study was to assess the reproducibility of using magnetic resonance imaging (MRI) to analyze the preserved anatomic knee compartments following unicondylar knee arthroplasty (UKA) with zirconium femoral components. It was hypothesized that evaluation of the cartilage, ligaments, meniscus, and tendons would result in a high rate of inter-observer reliability.
Scope: Ten patients underwent MRI of the knee tailored to reduce metallic artifact following medial UKA with zirconium femoral implants.
Background: For the clinical planning of mass events the emergency departments are of critical importance, but there are still no data available for the workload in these cases. As this is essential for an effective medical preparation, we calculated the workload based on the ICD codes of the vicitims at the Loveparade 2010 in Duisburg.
Material And Methods: Based on the patient data of the Loveparade 2010 we used a filter diagnosis to estimate the number of shock room patients, regular admittances, surgical wound treatments, applications of casts or splints, and diagnosis of drug abuse.
Aim: Two different measurement techniques of ultrasonograms of the infant hip were evaluated with respect to reproducibility of the Graf classification and variation of α- and β-angles.
Material And Methods: In a cross-sectional, blinded study, the hips of 207 consecutive newborn babies (101 male; 106 female) were sonographically screened at an average of 2.64 days after birth.
Several operative techniques have been described for recurrent patellar dislocation. Clinical results vary depending on the procedure and indication. The present study aimed to evaluate the clinical outcome of Insall's proximal realignment for recurrent patellar dislocation at mid-term follow-up.
View Article and Find Full Text PDFBackground: Today there are different subcutaneous and three oral applicable medications for prevention of venous thromboembolism after knee and hip replacement. It is a general opinion that patients will prefer oral administration. However, until today there has been no study that analysed patient preferences and motives for deciding on the kind of administration.
View Article and Find Full Text PDFHypothesis: Biomechanical studies have shown increased glenohumeral translation and loading of the long head biceps (LHB) tendon after superior labrum anterior to posterior (SLAP) tears. This may explain some of the typical clinical findings, including the prevalence of humeral chondral lesions, after SLAP lesions. The first hypothesis was that SLAP repair could restore the original glenohumeral translation and reduce the increased LHB load after SLAP lesions.
View Article and Find Full Text PDFStudy Design: Immunohistological study.
Objective: To elucidate the role of matrix metalloproteinases (MMPs), hypoxia-inducible factor-1α (HIF), and vascular endothelial growth factor (VEGF) in the hypertrophied ligamentum flavum (LF) obtained from patients with lumbar spinal stenosis (LSS).
Summary Of Background Data: The most common spinal disorder in the elderly is LSS, which results in part from LF hypertrophy.
Purpose: The affect of anterior cruciate ligament (ACL) integrity on the early postoperative stability of a collagen type-I gel scaffold was investigated. The value of fibrin glue for graft fixation in ACL deficient porcine knees over a simulated early postoperative period was also studied.
Methods: Full-thickness articular cartilage defects (11 × 6 mm) were created on the medial femoral condyle of 80 porcine knees.
Knee Surg Sports Traumatol Arthrosc
October 2012
Purpose: Several well-described techniques are available for the treatment of chondral and osteochondral defects. The aim of the study was to assess the efficacy of a single-stage procedure incorporating a new cell-free collagen type I gel for the treatment of small chondral and osteochondral defects in the knee evaluated at 2-year follow-up.
Methods: Fifteen patients were treated with a cell-free collagen type I gel matrix of 11 mm diameter.
Knee Surg Sports Traumatol Arthrosc
September 2012
Purpose: Meniscal loss is associated with an increased risk of developing osteoarthritis. Tissue engineering solutions, which include the development of novel material scaffolds, are being utilised to aid the regeneration of meniscal tissue. The purpose of this study was to monitor the safety profile and the short-term efficacy of a novel polyurethane meniscal scaffold in the treatment of patients with painful knees following partial medial meniscectomy.
View Article and Find Full Text PDFThe hypothalamic paraventricular nucleus (PVN) is a key site for regulating neuroendocrine functions in the magnocellular part and autonomic activities in the parvocellular part. Its anatomical proximity to the third ventricle could be a good target for intrathecal injection of baclofen. We investigated the correlation of intrathecal application of baclofen (a specific GABAB receptor agonist) and the release of epinephrine, norepinephrine, dopac, homovanillinic acid (HVA), glutamate and aspartate from the PVN.
View Article and Find Full Text PDFIntroduction: Adequate migration and differentiation of mesenchymal stem cells is essential for regeneration of large bone defects. To achieve this, modern graft materials are becoming increasingly important. Among them, electrospun nanofiber scaffolds are a promising approach, because of their high physical porosity and potential to mimic the extracellular matrix (ECM).
View Article and Find Full Text PDF