Publications by authors named "Schlottig F"

Osseointegration of dental implants can be promoted by implant-surface modifications using bisphosphonate coatings. In addition, it is of clinical interest to promote peri-implant bone formation and to restore bony structure in low bone-mass patients. The present study evaluated a combination of an anti-resorptive zoledronic acid (ZOL) implant-coating and a systemically applied sclerostin antibody, a known bone anabolic treatment principle, versus sole sclerostin antibody treatment or ZOL implant-coating in a rat osteoporosis model.

View Article and Find Full Text PDF

Our ability of screening broad communities for clinically asymptomatic diseases critically drives population health. Sensory chewing gums are presented targeting the tongue as 24/7 detector allowing diagnosis by "anyone, anywhere, anytime". The chewing gum contains peptide sensors consisting of a protease cleavable linker in between a bitter substance and a microparticle.

View Article and Find Full Text PDF

Blood clots stop bleeding and provide cell-instructive microenvironments. Still, in vitro models used to study implant performance typically neglect any possible interactions of recruited cells with surface-adhering blood clots. Here we study the interaction and synergies of bone marrow derived human mesenchymal stem cells (hMSCs) with surface-induced blood clots in an in vitro model by fluorescence microscopy, scanning and correlative light and electron microscopy, ELISA assays and zymography.

View Article and Find Full Text PDF

The present study aimed to evaluate primary stability (PS) and osseointegration of dental implants in polylactide [70/30 poly(l-lactide-co-d, l-lactide); (PLDLA)] modified bone in 30 Goettingen minipigs. Each animal received three implants per jaw quadrant. In a split-mouth design, one side of the maxilla and mandible was randomly allocated to the experimental treatment (PLDLA applied into the drill hole before implantation), while the contralateral sides served as intraindividual controls (no PLDLA applied).

View Article and Find Full Text PDF

Background: Screw anchorage in osteoporotic bone is still limited and makes treatment of osteoporotic fractures challenging for surgeons. Conventional screws fail in poor bone quality due to loosening at the screw-bone interface. A new technology should help to improve this interface.

View Article and Find Full Text PDF

Low correlations of cell culture data with clinical outcomes pose major medical challenges with costly consequences. While the majority of biomaterials are tested using in vitro cell monocultures, the importance of synergistic interactions between different cell types on paracrine signalling has recently been highlighted. In this proof-of-concept study, we asked whether the first contact of surfaces with whole human blood could steer the tissue healing response.

View Article and Find Full Text PDF

Objectives: The aim of this study was to evaluate the clinical performance of local cancellous bone amelioration by a 70:30 poly-(L-lactide-co-D,L-Lacide) copolymer with two different implant designs on primary stability and after 4 and 12 weeks of healing time.

Material And Methods: In six sheep, n = 36 implants (TH) with a conditioned, sandblasted, thermal acid-etched micro-rough surface and n = 36 implants (NB) with a highly crystalline and phosphate-enriched anodized titanium oxide surface were placed in the pelvic bone. Using an ultrasound-based process named Constant Amelioration Process (CAP), half of peri-implant trabecular bone structures were locally tested with 70:30 poly-(L-lactide-co-D,L-Lacide) copolymer in both implant groups, TH and NB.

View Article and Find Full Text PDF

Objective: The first objective of this pilot study was to evaluate the impact of the hydrophilicity on the early phases of osseointegration. The second objective was to compare two hydrophilic implant surfaces with different geometries, surface roughness, and technologies achieving hydrophilicity.

Material And Methods: Twelve weeks after extraction, all four quadrants of nine minipigs received three dental implants, alternating between hydrophilic microrough surfaces (INICELL and SLActive) and a conventional hydrophobic microrough surface.

View Article and Find Full Text PDF

The present study examined the impact of implant surface modifications on osseointegration in an osteoporotic rodent model. Sandblasted, acid-etched titanium implants were either used directly (control) or were further modified by surface conditioning with NaOH or by coating with one of the following active agents: collagen/chondroitin sulphate, simvastatin, or zoledronic acid. Control and modified implants were inserted into the proximal tibia of aged ovariectomised (OVX) osteoporotic rats (n = 32/group).

View Article and Find Full Text PDF

Osteoclasts are responsible for bone resorption and implant surface roughness promotes osseointegration. However, little is known about the effect of roughness on osteoclast activity. This study aims at the characterization of osteoclastic response to surface roughness.

View Article and Find Full Text PDF

Objectives: Osseointegration is dependent on different parameters of the implant surface like surface roughness and physicochemical properties. In vitro studies using a wide variety of surface parameters and cell lines make it difficult to address the influence of a single parameter. With this study the influence of surface topography and energy on different osteoblast derived cell lines, namely MG-63 and SaOS-2 and of human mesenchymal stromal cells (hMSC) were investigated.

View Article and Find Full Text PDF

Titanium implants are most commonly used for bone augmentation and replacement due to their favorable osseointegration properties. Here, hyperhydrophilic sand-blasted and acid-etched (SBA) titanium surfaces were produced by alkali treatment and their responses to partially heparinized whole human blood were analyzed. Blood clot formation, platelet activation and activation of the complement system was analyzed revealing that exposure time between blood and the material surface is crucial as increasing exposure time results in higher amount of activated platelets, more blood clots formed and stronger complement activation.

View Article and Find Full Text PDF

Two groups of titanium dental implants, identical in geometry but different in the treatment of their surfaces, were tested in an in vivo minipig model of the mandible. The surfaces that were tested were, first, sandblasted and acid-etched; and secondly, sandblasted, acid-etched, and conditioned. The removal torque was assessed at 2, 4, and 8 weeks after implantation (n=6 animals in each healing period).

View Article and Find Full Text PDF

A new strategy to render intrinsically hydrophobic microrough titanium implant surfaces superhydrophilic is reported, which is based on a rapid treatment with diluted aqueous sodium hydroxide solutions. The physicochemical characterization and protein interaction of the resulting superhydrophilic implant surfaces are presented. The superhydrophilicity of alkali treated microrough titanium substrates was mainly attributed to deprotonation and ion exchange processes in combination with a strong enhancement of wettability due to the roughness of the used substrates.

View Article and Find Full Text PDF

Osteoclasts resorb bone at surfaces, leaving behind pits and trails where both mineral and organic phases of bone have been dissolved. Rough surface structures are deliberately imparted to synthetic implants, in order to improve osseointegration. The aim of this study is to characterize osteoclastic resorption pits on native bone surfaces and to compare these with state-of-the-art titanium and zirconia implant surfaces.

View Article and Find Full Text PDF

Aim: To test the hypothesis that peri-implant bone formation and mechanical stability of surface-modified zirconia and titanium implants are equivalent.

Materials And Methods: Twelve minipigs received three types of implants on either side of the mandible 8 weeks after removal of all pre-molar teeth: (i) a zirconia implant with a sandblasted surface; (ii) a zirconia implants with a sandblasted and etched surface; and (iii) a titanium implant with a sandblasted and acid-etched surface that served as a control. Removal torque and peri-implant bone regeneration were evaluated in six animals each after 4 and 13 weeks.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate crestal bone resorption and bone apposition resulting from immediate post-extraction implants in the canine mandible, comparing a conditioned sandblasted acid-etched implant surface with a non-conditioned standard sandblasted implant surface.

Material And Methods: In this experimental study, third and fourth premolars and distal roots of first molars were extracted bilaterally from six Beagle dog mandibles. Each side of the mandible received three assigned dental implants, with the conditioned surface (CS) on the right side and the non-conditioned surface (NCS) on the left.

View Article and Find Full Text PDF

The effect of two different etching procedures with inorganic acids (HSE and CSE)-one using additionally strongly oxidising conditions due to the presence of CrO(3) (CSE)-and consecutive storage conditions (dry methanol and air) for previous corundum blasted titanium surfaces is compared with respect to their wettability behaviour and the potential of the etching processes for removing remaining blasting material. The etching procedures result in distinct different surface morphologies. Whereas the HSE surface shows sub-mm to sub-mum structures but neither porosity nor undercuts, the CSE surface is extremely rugged and porous with structures protruding the more homogeneously attacked areas by several micrometers.

View Article and Find Full Text PDF

Aim: The aim of this study was to determine whether bone formation around surface-conditioned implants is enhanced compared with non-surface-conditioned sandblasted acid-etched titanium implants.

Materials And Methods: One hundred and forty-four implants were placed in the mandible of 18 minipigs. Before placement, implants were either surface conditioned in a solution containing hydroxide ions (conSF) or assigned to controls.

View Article and Find Full Text PDF

Objectives: Zirconia is a suitable biomaterial for use in medicine (stomatology, orthopaedics) due to its good biocompatibility and outstanding mechanical properties. This study compares the effect of (i) zirconia to the widely used titanium and (ii) zirconia with two different surface topographies (sandblasted and sandblasted/etched) on the adhesion, proliferation and differentiation of SAOS-2 osteoblasts.

Methods: SAOS-2 cells were cultured on either sandblasted or sandblasted/etched zirconia and compared with sandblasted/etched titanium.

View Article and Find Full Text PDF

Purpose: A satisfactory clinical outcome in dental implant treatment relies on primary stability for immediate load bearing. While the geometric design of an implant contributes to mechanical stability, the nature of the implant surface itself is also critically important. Biomechanical and microcomputerized tomographic evaluation of implant osseointegration was performed to compare alternative structural, chemical and biochemical, and/or pharmaceutical surface treatments applied to an identical established implant design.

View Article and Find Full Text PDF

Advanced surface modifications and materials were tested on the same implant geometry. Six types of dental implants were tested for osseointegration after 2, 4 and 8 weeks in a sheep pelvis model. Four titanium implant types were treated with newly developed surface modifications, of which two were chemically and two were pharmacologically modified.

View Article and Find Full Text PDF

The aim of the present study was to characterize the surface morphology, microstructure and the chemical composition of anodic spark-converted titanium surfaces. The coatings were prepared in an electrochemical cell by the anodic spark deposition technique in an aqueous solution of Ca(H2PO4)2. The coatings were characterized by X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), electron probe microanalysis (EPMA) and X-ray diffraction (XRD).

View Article and Find Full Text PDF

The anodic plasma-chemical (APC) process was used to modify CP titanium surfaces for biomedical applications. This technique allows for the combined chemical and morphological modification of titanium surfaces in a single process step. The resulting conversion coatings, typically several micrometer thick, consist mainly of titanium oxide and significant amounts of electrolyte constituents.

View Article and Find Full Text PDF