Purpose: Especially in Europe, amino acid PET is increasingly integrated into multidisciplinary neuro-oncological tumor boards (MNTBs) to overcome diagnostic uncertainties such as treatment-related changes. We evaluated the accuracy of MNTB decisions that included the O-(2-[18F]-fluoroethyl)-L-tyrosine (FET) PET information compared with FET PET results alone to differentiate tumor relapse from treatment-related changes.
Patients And Methods: In a single academic center, we retrospectively evaluated 180 MNTB decisions of 151 patients with CNS WHO grade 3 or 4 gliomas (n = 122) or brain metastases (n = 29) presenting equivocal MRI findings following anticancer treatment.
Objective: The purpose of this study was to evaluate the effectiveness of a deep learning model (DLM) in improving the sensitivity of neurosurgery residents to detect intracranial aneurysms on CT angiography (CTA) in patients with aneurysmal subarachnoid hemorrhage (aSAH).
Methods: In this diagnostic accuracy study, a set of 104 CTA scans of aSAH patients containing a total of 126 aneurysms were presented to three blinded neurosurgery residents (a first-year, third-year, and fifth-year resident), who individually assessed them for aneurysms. After the initial reading, the residents were given the predictions of a dedicated DLM previously established for automated detection and segmentation of intracranial aneurysms.
Intrasaccular flow disruption with the Woven Endobridge (WEB) has become a well-established endovascular technique for the treatment of intracranial aneurysms. This study presents our 12-year experience with the WEB and evaluates its evolving indications, procedures, and outcomes. A consecutive series of 324 aneurysms treated with WEB between 2011 and 2023 at three neurovascular centers was retrospectively analyzed and the study group was divided into four treatment periods.
View Article and Find Full Text PDFBackground And Purpose: The Pipeline Embolization Device is a safe and effective treatment option for intracranial aneurysms. The newer Pipeline generations have received structural refinements and a surface modification to improve deliverability, procedural safety, and angiographic outcomes. This multicenter study evaluated the clinical safety and efficacy of the 2 surface-modified Pipeline iterations, Pipeline Vantage and Pipeline Flex with Shield Technology (PFS).
View Article and Find Full Text PDFObjective: The Pipeline Vantage Embolization Device (PVED) is a novel coated flow diverter with reduced wire diameters to improve neoendothelialization and stent porosity. This systematic review evaluates the safety and efficacy of the PVED based on the current literature.
Methods: Following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines, a thorough literature search was conducted using PubMed, EMBASE, and Cochrane.
Purpose: The WEB 17 system represents the fifth generation of Woven Endobridge (WEB) flow disruptors and features a low profile with fewer wires than its predecessor, the WEB 21. The present study compares the safety and efficacy of the WEB 17 and WEB 21 for the treatment of unruptured cerebral aneurysms with 4-7 mm device sizes, which were available for both systems.
Methods: Patient and aneurysm characteristics, complications, clinical outcome and angiographic results were retrospectively analysed.
Purpose: Multi-sac aneurysms (MSAs) are not uncommon, but studies on their management are scarce. This study aims to evaluate and compare the feasibility, safety, and efficacy of MSAs treated with either clipping or coiling after interdisciplinary case discussion at our center.
Materials And Methods: We retrospectively analyzed MSAs treated by microsurgical clipping, coiling, or stent-assisted coiling (SAC).
Background And Objectives: In light of limited intensive care capacities and a lack of accurate prognostic tools to advise caregivers and family members responsibly, this study aims to determine whether automated cerebral CT (CCT) analysis allows prognostication after out-of-hospital cardiac arrest.
Methods: In this monocentric, retrospective cohort study, a supervised machine learning classifier based on an elastic net regularized logistic regression model for gray matter alterations on nonenhanced CCT obtained after cardiac arrest was trained using 10-fold cross-validation and tested on a hold-out sample (random split 75%/25%) for outcome prediction. Following the literature, a favorable outcome was defined as a cerebral performance category of 1-2 and a poor outcome of 3-5.
Purpose: This study analyzes the long-term clinical and angiographic outcomes of the Derivo Embolization Device (DED), an advanced flow diverter device with an electropolished surface, for the treatment of intracranial aneurysms.
Methods: A consecutive series of 101 patients (mean age: 58 years, 72% female) treated with the DED for 122 aneurysms at a single center between 2017 and 2023 was retrospectively analyzed for major (change in National Institutes of Health Stroke Scale [NIHSS] score ≥ 4 points) and minor (change in NIHSS score < 4 points) neurological events, procedural morbidity (increase of at least one point on the modified Rankin Scale), and angiographic results.
Results: There were 14 (11%) recurrent aneurysms, 15 (12%) ruptured aneurysms, 26 (21%) posterior circulation aneurysms and 16 (13%) fusiform or dissecting aneurysms.
Objective: There are few studies on flow diverters with diameters >5 mm. We present our preliminary experience with the 5.5-8 mm Derivo Embolization Device (DED) implants for the treatment of cerebral aneurysms.
View Article and Find Full Text PDFObjective: The flow re-direction endoluminal device (FRED) is a safe and effective treatment option for intracranial aneurysms. The novel FRED X features an antithrombotic surface coating ("X Technology") on an otherwise unmodified stent design. This two-center study evaluates the clinical safety and efficacy of FRED X and compares it to the literature.
View Article and Find Full Text PDFIntra-arterial nimodipine administration is a widely used rescue therapy for cerebral vasospasm. Although it is known that its effect sets in with delay, there is little evidence in current literature. Our aim was to prove that the maximal vasodilatory effect is underestimated in direct angiographic controls.
View Article and Find Full Text PDFObjective: In preliminary studies, advanced intracranial stents appear to have a favorable safety profile for intracranial aneurysm treatment. This dual-center study is a head-to-head comparison of the low-profile Acandis Acclino stent (a third-generation stent) and the first- and second-generation Enterprise stent.
Methods: Patients who underwent stent-assisted coiling with either the Enterprise or the Acclino stent for unruptured aneurysms during an 8-year period were enrolled and compared for complications, clinical outcomes, and angiographic results.
Objective: Several studies have demonstrated a high safety and efficacy profile of the Woven EndoBridge (WEB) for endovascular aneurysm treatment. However, contemporary large-scale studies of the WEB are rare. This multicenter study attempts to set a benchmark for state-of-the-art WEB treatment with consistent application of the WEB oversizing technique.
View Article and Find Full Text PDFObjective: The low-profile Acandis Acclino flex plus (AFP) is a fourth-generation laser-cut microstent with a flexible structure designed for the treatment of a wide variety of aneurysms. We report our single-center experience with this device in the treatment of complex aneurysms.
Methods: Twenty-eight patients were treated with the Acclino flex plus for 28 aneurysms.
Survival under selective pressure is driven by the ability of our brain to use sensory information to our advantage to control physiological needs. To that end, neural circuits receive and integrate external environmental cues and internal metabolic signals to form learned sensory associations, consequently motivating and adapting our behaviour. The dopaminergic midbrain plays a crucial role in learning adaptive behaviour and is particularly sensitive to peripheral metabolic signals, including intestinal peptides, such as glucagon-like peptide 1 (GLP-1).
View Article and Find Full Text PDFObjective: The development of new flow-diverting devices with antithrombotic coatings may result in an improved safety profile, particularly a reduction in ischaemic stroke rates. The aim of this study was to evaluate our initial experience with the recently introduced coated Derivo® 2heal® Embolization Device (Acandis, Pforzheim, Germany).
Methods: This is a retrospective, single-centre analysis of patients with intracranial aneurysms undergoing Derivo® 2heal® Embolization Device treatment.
Purpose: Information about the cost-effectiveness of a certain treatment is relevant for decision-making and healthcare providers. This study compares the cost-effectiveness of the novel Woven Endobridge (WEB) for intracranial aneurysm treatment with conventional coiling and stent-assisted coiling (SAC) from the perspective of the German Statutory Health Insurance.
Methods: A patient-level simulation was constructed to simulate 55-year-old patients with an unruptured middle cerebral artery aneurysm (size: 3-11 mm) considering WEB treatment, coiling or SAC in terms of morbidity, angiographic outcome, retreatment, procedural and rehabilitation costs and rupture rates.