Objectives: To in-vitro evaluate the feasibility and accuracy (trueness and precision) of various intraoral scanners (IOS) to digitize maxillectomy defect models with exposed zygomatic implants in situ.
Material And Methods: Six partially edentulous and edentulous maxillectomy defect models with 2 zygomatic implants each were obtained. References scans were obatined by using a laboratory scanner (inEos X5; Dentsply Sirona).
Purpose: The COVID-19 pandemic raised the question about the extent of microbial exposure encountered by dentists during dental therapy. The purpose of this study was to quantify microbial counts on surgical masks related to duration and type of dental therapy, as well as patient oral health variables.
Materials And Methods: Sterile filter papers were fixed on surgical masks used during routine daily dental therapy.
Objective: To evaluate the effect of build orientation on the fabrication trueness and fit of additively manufactured 2-piece zirconia abutments when compared with those manufactured subtractively in 3 mol% and 4 mol% yttria-stabilized zirconia (3Y-TZP and 4Y-TZP).
Methods: A titanium-base (Ti-base) abutment was digitized with a scan body and an industrial scanner to design a 2-piece zirconia abutment with a 50 µm cement gap. This design was used to manufacture zirconia abutments additively in different orientations (0-degree, AM-0; 15-degree, AM-15; 30-degree, AM-30; 45-degree, AM-45; 180-degree, AM-180) and subtractively from 3Y-TZP and 4Y-TZP (SM-3 and SM-4) (n=5).
Objective: This case report illustrates a clinical scenario of a patient with insufficient crowns, gold onlays and localized tooth pain in the posterior teeth, treated with partial and full coverage lithium disilicate restorations.
Clinical Considerations: A female patient presented in the clinics, complaining about tooth pain and unesthetic metal restorations. After a thorough examination, diagnosis and treatment plan, the existing restorations were removed, and a defect-oriented preparation was done to preserve as much as possible of the remaining tooth structure.
Statement Of Problem: Currently available 3-dimensional (3D) additively manufactured (AM) resins used for definitive restorations have different chemical compositions and viscosities. The fabrication trueness and margin quality of laminate veneers additively manufactured with different resins have not been extensively studied.
Purpose: The purpose of this in vitro study was to evaluate the fabrication trueness and margin quality of AM and subtractively manufactured (SM) definitive resin-based laminate veneers.
We present the characterization of the sources of vibration in the open-pit Riotinto mine (southern Spain), based on the data recorded by a dense seismic network of 30 stations located along a 1-km long segment of a tailings dam. We describe the most common transient signals detected, including local and distant earthquakes, blasting and vehicles. The time variations in the amplitude of the 10-40 Hz frequency band are then used to define three phases of activity during the recording period.
View Article and Find Full Text PDFBackground: Within the fields of medicine and music, increasing attention is given to evidence indicating music performance being an occupational risk factor for temporo-mandibular disorders (TMD).
Objectives: Assessment of self-reported painful TMD symptoms among student and professional musicians.
Methods: Using Survey Monkey software, the German version of the 'TMD-Pain-Screener' was distributed electronically to professional and student musicians in Europe.
Purpose: To evaluate the distortion probability in impressions of completely dentate arches when different impression materials are used in relation to operator experience.
Materials And Methods: A total of 28 students (Group A) and 7 dentists (Group B) performed three maxillary impressions on 28 participants, each using vinyl siloxane ether (VSE), polyether (PE), and irreversible hydrocolloid (IHC). Gypsum master casts were fabricated and subsequently digitized.
Objectives: This study aimed to compare the design outcomes of anterior crowns generated using deep learning (DL)-based software with those fabricated by a technician using conventional dental computer-assisted design (CAD) software without DL support, with a focus on the evaluation of crown morphology, function, and aesthetics.
Methods: Twenty-five in vivo datasets comprising maxillary and mandibular arch scans of prepared maxillary central incisors were utilized to design anterior crowns by using three methods: 1) a DL-based method resulting in as-generated outcome (DB), 2) a DL-based method further optimized by a technician (DM), and 3) a conventional CAD-based method (NC, control). Evaluations were conducted for crown morphology (total discrepancy volume (TDV), root mean square (RMS), positive average (PA) and negative average (NA) deviations), functional aspects (incisal path: deviations, length, and mean inclination), and aesthetics (crown width, height, width-to-height ratio, angular radius of mesioincisal line angle, proximal contact length, and tooth axis angle).
Autosomal-dominant polycystic kidney disease (ADPKD) is a common monogenic disease characterized by the formation of fluid-filled renal cysts, loss of mitochondrial function, decreased fatty acid oxidation, increased glycolysis, and likely renal failure. We previously demonstrated that inducing a state of ketosis ameliorates or reverses PKD progression in multiple animal models. In this study, we compare time-restricted feeding and 48-h periodic fasting regimens in both juvenile and adult Cy/+ rats.
View Article and Find Full Text PDFAim: This is a report of the 5-year results of a two-group parallel randomized clinical trial comparing longitudinal implant stability, and clinical and radiographic peri-implant outcomes of mandibular overdentures retained by one (1-IOD group) or two (2-IOD group) implants.
Methods: All participants received 4.1 mm diameter tissue-level implants (Straumann Standard Plus - SLActive, Institut Straumann AG), installed in the mandible midline (1-IOD; n = 23) or the lateral incisor-canine area bilaterally (2-IOD; n = 24), and loaded after 3 weeks.
Objectives: To digitally evaluate the trueness and fit of additively and subtractively manufactured fixed complete dentures in materials intended for definitive use.
Methods: An edentulous maxillary model with implants at the left first molar, left canine, right canine, and right first molar site was digitized and a fixed complete denture was designed. This design was used to fabricate fixed dentures in an additively manufactured resin for definitive use (AM), a high-impact polymer composite (SM-CR), and a strength gradient zirconia (SM-ZR) (n = 10).
Int J Environ Res Public Health
July 2024
(1) Background: Insufficient data exist regarding oral function among older adults in Europe. Therefore, we aimed to assess and compare oral function between older in- and outpatients and identify predictors of low masticatory performance. (2) Methods: Patients were consecutively recruited from the outpatient center ( = 31) and the inpatient geriatric department ( = 31) at a tertiary University Hospital in Switzerland in 2023.
View Article and Find Full Text PDFA new accessory was developed to allow implantation of left ventricular assist devices (LVADs) without requiring an anastomosis to the ascending aorta. The accessory combines the LVAD inflow and outflow into a dual-lumen device. Initial prototypes encountered reduced pump performance in vitro, but a second-generation prototype successfully addressed this issue.
View Article and Find Full Text PDFObjectives: Teaching communication skills plays a pivotal role in medical curricula. The aim of this article is to describe and evaluate a new communication curriculum developed at the Faculty of Medicine, University of Augsburg (KomCuA), which was conceptualized by an interdisciplinary team based on recommended quality standards (i.e.
View Article and Find Full Text PDFObjective: This 2-year prospective study reports the incidence of prosthetic complications and maintenance events after treatment with mandibular overdenture retained by four mini implants opposed to a maxillary denture.
Methods: Implant intervention included flapless or flapped surgery combined with immediate or delayed loading, as part of a randomized clinical trial. Four one-piece titanium-zirconium mini-implants (Straumann Mini Implant System) were inserted, and the retentive PEEK elements (Optiloc) were incorporated into the overdenture using chairside procedures.
The positive impact of implant interventions on dental patient-reported outcomes is an essential parameter of treatment effectiveness. This study assessed the 2-year changes in patient satisfaction and oral health-related quality of life (OHRQoL) of edentulous patients treated with a four mini implant mandibular overdenture (IOD) METHODS: The study was planned as a 2 × 2 factorial randomized clinical trial that tested two surgical approaches (flapped or flapless) and two loading protocols (immediate and delayed) using a titanium-zirconium mini implant (Straumann Mini Implant System®) and a PEEK retentive system (Straumann® Optiloc® Retentive System). Outcome measures (OHIP-Edent scores and the McGill Denture Satisfaction questionnaire) were assessed before treatment and at the 3-, 6-, 12-, and 24-month follow-ups.
View Article and Find Full Text PDFClin Oral Implants Res
November 2024
Objective: To assess the relative position of mini-implants to retain a mandibular overdenture, according to the surgical protocol, technical and anatomical factors.
Methods: Mandibular cone-beam computed tomography (CBCT) scans were analyzed for 73 patients who received four one-piece titanium-zirconium mini-implants. Drilling was performed using a 1.
Purpose: The purpose of the study was to assess and compare the masticatory performance in children receiving preformed metal crown by Hall technique and conventional technique.
Methods: Children having teeth indicated for restorative/endodontic therapy and belonging to the age group of six to ten years were invited to participate in the study. Eighteen children received preformed metal crowns (PMCs) by Hall technique.
Background: There is limited knowledge on the fabrication trueness and fit of additively or subtractively manufactured complete-arch implant-supported frameworks in recently introduced polymers.
Purpose: To evaluate the trueness and marginal fit of additively or subtractively manufactured polymer-based complete-arch implant-supported frameworks, comparing with those of strength gradient zirconia frameworks.
Materials And Methods: A typodont model with 4 implants (left first molar (abutment 1), left canine (abutment 2), right canine (abutment 3), and right first molar (abutment 4)) was digitized (ATOS Core 80 5MP) and an implant-supported complete-arch framework was designed.
Purpose: To analyse the association of masticatory performance and oral health-related quality of life in a representative population of individuals residing in communities in Switzerland aged ≥ 45 years.
Materials And Methods: In total, 100 subjects completed two dedicated and validated questionnaires on their demographic data and the Geriatric Oral Health Assessment Index. A mixing ability test was performed for assessing masticatory performance.
Objectives: To compare implant supported crowns (ISCs) designed using deep learning (DL) software with those designed by a technician using conventional computer-aided design software.
Methods: Twenty resin-based partially edentulous casts (maxillary and mandibular) used for fabricating ISCs were evaluated retrospectively. ISCs were designed using a DL-based method with no modification of the as-generated outcome (DB), a DL-based method with further optimization by a dental technician (DM), and a conventional computer-aided design method by a technician (NC).