We report a reliable radioimmunoassay for plasma progesterone in which polyethylene glycol ("Carbowax 6000") is used to separate antibody-bound and free hormone. Initially, progesterone is concentrated by putting the sample through a column of LH-20 Sephadex. Procedural losses in each sample are not monitored.
View Article and Find Full Text PDFJ Neurol Neurosurg Psychiatry
August 1976
Using a single fibre EMG electrode the firing pattern of 46 motor units in the triceps surae has been studied during vibration of the Achilles tendon at frequencies of 25--200 Hz. Potentials activated in the tonic vibration reflex (TVR) were phase-locked to the vibration cycle but tended to become somewhat less so with continued vibration. The firing pattern of voluntarily activated motor units became locked to the waveform by the application of the vibrator.
View Article and Find Full Text PDFA rapid, non-chromatographic radioimmunossaay for unconjugated estriol in pregnancy plasma has been developed which utilizes a commonly available antiestrogen antisera. Estradiol-17beta and estrone demonstrate 135% relative cross-reactivity with our antiserum, as compared with 100% for estriol. Specificity is achieved by purification of estriol with solvent partitioning using benzene: petroleum ether (1:1).
View Article and Find Full Text PDFThe motor unit in the normal EDC and biceps brachii muscle was studied with a multielectrode technique permitting recording from 44 sites 300 mum apart. It was found that the muscle fibres in man are scattered with no evidence of grouping, similar to the findings in glycogen depletion experiments in animals.
View Article and Find Full Text PDFWe describe a rapid, reliable radioimmunoassay for unconjugated estriol in plasma. Polyethylene glycol (Carbowax 6000) is used to separate antibody-bound and free steroid. The assay is sensitive (25 pg for standards), precise, and accurate.
View Article and Find Full Text PDFMotor units in patients with motor neurone disease and polyneuropathy were studied with a new multielectrode technique allowing fibre mapping. In these disorders which are characterised by reinnervation the motor unit fibre distribution is changed from a normal scattered pattern to grouping often in clinically uninvolved muscles without definite EMG abnormalities. The changes found with this multielectrode technique in man are in accordance with those found in reinnervated motor units studied histochemically in the experimental animal.
View Article and Find Full Text PDFJ Steroid Biochem
January 1976
J Neurol Neurosurg Psychiatry
August 1975
A method employing six minutes of regional curarization with 0.5 mg D-tubocurarine and single fibre electromyographic measurements (SFEMG) was used in order to study the effect of an additional small dose of D-tubocurarine. The effect of the additional dose was most pronounced in terms of increased jitter, on motor end-plates with the initially highest jitter.
View Article and Find Full Text PDFJ Neurol Neurosurg Psychiatry
August 1975
In a single fibre EMG investigation on healthy subjects the relationship between the neuromuscular jitter and the safety factor of the motor end-plate relative to curare was studied. A positive correlation was found between the jitter increase after a standard dose of D-tubocurarine and the initial jitter. The conclusion was drawn that the neuromuscular jitter can be used as an indicator of the safety factor.
View Article and Find Full Text PDFWe have developed a simple, reliable radioimmunoassay for plasma 11-deoxycortisol. The method does not require chromatography but instead makes use of a simple extraction procedure which, in combination with the antibody characteristics, is highly specific for the metyrapone test. Polyethylene glycol was used to separate free and antibody-bound steroid.
View Article and Find Full Text PDFWe have developed a reliable radioimmunoassay for testosterone in plasma, polyethylene glycol ("Carbowax 6000") being used to separate antibody-bound and free hormone. Testosteron is separated from interfering steroids, notably dihydrotestosterone, by liquid-liquid partition chromatography on infusorial earth (Celite). The assay is sensitive (9 pg for standards), precise, and accurate.
View Article and Find Full Text PDFThe luteolytic activity of oxymetholone, and anabolic steroid, has been evaluated in 10 women. Administration early in the follicular phase of the cycle inhibited ovulation and prolonged the duration of the cycles in 2 of 3 subjects, but treatment beginning on Day 10 (3 subjects) did not prevent ovulation, although subsequent plasma progesterone concentrations were reduced. Treatment after ovulation (4 subjects) suppressed progesterone levels by 50 to 80 per cent and shortened cycle length by 6 to 8 days.
View Article and Find Full Text PDF