Many studies have clearly established that chronic psychosocial stress may sustainably worsen glycemic control in patients with type 1 diabetes mellitus (T1DMM), thus promoting diabetes complications. Chronic psychosocial stress may be due to: i) the long-term accumulation of stressful life events that require readjustment on the part of the individual (loosing friends, changing schools), and/or ii) exposure to severe chronic stressors (persistent difficulties and adversities of life). Whatever the reason, many studies have clearly established a positive correlation between chronic psychosocial stress and HbA1c levels.
View Article and Find Full Text PDFBackground: Support programs are provided to people with diabetes to help them manage their disease. However, adherence to and persistence in support programs are often low, making it difficult to demonstrate their effectiveness.
Aim: To identify the determinants of patients' perceived interest in diabetes support programs because it may be a powerful determinant of effective participation in such programs.
Background: To evaluate the impact of switching from U-100 to U-500 insulin in patients with type 2 diabetes mellitus (T2DM) uncontrolled with continuous subcutaneous insulin infusion (CSII) by pump.
Methods: We retrospectively collected data from patients with T2DM, treated by U-100 CSII, who were switched to U-500 regular insulin where haemoglobin A1c (Hb) was >8% and/or insulin total daily dose (TDD) was >100 UI/d. Data collection from patient medical records included Hb, lipid levels, liver biomarkers, weight, TDD, declared hypoglycaemic episodes and measured by continuous glucose monitoring (CGM).
The switch from intermittently scanned continuous glucose monitoring (isCGM) to real-time (rt) CGM could improve glycemic management in suboptimal controlled type 1 diabetes patients, but long-term study is lacking. We evaluated retrospectively the ambulatory glucose profile (AGP) in such patients after switching from Free Style Libre 1 (FSL1) to Dexcom G4 (DG4) biosensors over 1 year. Patients ( = 21, 43 ± 15 years, BMI 25 ± 5, HbA1c 8.
View Article and Find Full Text PDFA post hoc analysis of the Diabeloop WP7 multicentre, randomized controlled trial was performed to investigate the efficacy of the Diabeloop Generation-1 (DBLG1) closed-loop system in controlling the hypoglycaemia induced by physical activity (PA) in real-life conditions. Glycaemic outcomes were compared between days with and without PA in 56 patients with type 1 diabetes (T1D) using DBLG1 for 12 weeks. After the patient announces a PA, DBLG1 reduces insulin delivery and, if necessary, calculates the amount of preventive carbohydrates (CHO).
View Article and Find Full Text PDFDiabetes Technol Ther
August 2021
Automated closed-loop (CL) insulin therapy has come of age. This major technological advance is expected to significantly improve the quality of care for adults, adolescents and children with type 1 diabetes. To improve access to this innovation for both patients and healthcare professionals (HCPs), and to promote adherence to its requirements in terms of safety, regulations, ethics and practice, the French Diabetes Society (SFD) brought together a French Working Group of experts to discuss the current practical consensus.
View Article and Find Full Text PDFAssess the impact of switching from intermittently scanned (FreeStyle Libre [FSL]) to real-time (Dexcom G4 platinum [DG4]) continuous glucose monitoring systems on glycemia control in type 1 diabetes (T1D) patients with high risk of hypoglycemia and/or elevated glycated hemoglobin (HbA1c). We conducted an observational study in 18 T1D adults with poor glycemic control on FSL. Ambulatory glucose profile data were collected during the last 3 months of FSL use before inclusion (M0 period), during the first 3 months (M3 period) and the last 3 months (M6 period) of DG4 use.
View Article and Find Full Text PDFThe DIABEO system (DS) is a telemedicine solution that combines a mobile app for patients with a web portal for health care providers. DS allows real-time monitoring of basal-bolus insulin therapy as well as therapeutic decision-making, integrating both basal and bolus dose calculation. Real-life studies have shown a very low rate of use of mobile health applications by patients.
View Article and Find Full Text PDFAims: To compare closed-loop (CL) and open-loop (OL) systems for glycaemic control in patients with type 1 diabetes (T1D) exposed to real-life challenging situations (gastronomic dinners or sustained physical exercise).
Methods: Thirty-eight adult patients with T1D were included in a three-armed randomized pilot trial (Diabeloop WP6.2 trial) comparing glucose control using a CL system with use of an OL device during two crossover 72-hour periods in one of the three following situations: large (gastronomic) dinners; sustained and repeated bouts of physical exercise (with uncontrolled food intake); or control (rest conditions).
TeleDiab-2 was a 13-month randomized controlled trial evaluating the efficacy and safety of two telemonitoring systems to optimize basal insulin (BI) initiation in subjects with inadequately controlled type 2 diabetes (HbA1c, 7.5%-10%). A total of 191 participants (mean age 58.
View Article and Find Full Text PDFBackground: Closed-loop insulin delivery systems are expected to become a standard treatment for patients with type 1 diabetes. We aimed to assess whether the Diabeloop Generation 1 (DBLG1) hybrid closed-loop artificial pancreas system improved glucose control compared with sensor-assisted pump therapy.
Methods: In this multicentre, open-label, randomised, crossover trial, we recruited adults (aged ≥18 years) with at least a 2 year history of type 1 diabetes, who had been treated with external insulin pump therapy for at least 6 months, had glycated haemoglobin (HbA) of 10% or less (86 mmol/mol), and preserved hypoglycaemia awareness.
Benefits of telemedicine have been proven in the field of diabetes. Among a number of technical solutions, Diabeo® has been studied in both type 1 and type 2 diabetes with intensive insulin therapy. This digital therapeutic system contains a self-monitoring glucose logbook and offers automated insulin dose recommendations thanks to a fully customizable algorithm.
View Article and Find Full Text PDFBackground: Self-management of diabetes minimizes the risk of macrovascular and microvascular complications, but understanding and/or adherence to self-management recommendations is often suboptimal. DIABEO is a smartphone app (downloaded via the internet) used to calculate bolus insulin doses. A previous study (TELEDIAB 1) showed that the use of DIABEO was associated with a significant improvement in glycemic control in patients with poorly controlled type 1 diabetes mellitus, particularly when combined with teleconsultations with physicians.
View Article and Find Full Text PDFThe use by diabetes patients of real-time continuous interstitial glucose monitoring (CGM) or the FreeStyle Libre (FSL) flash glucose monitoring (FGM) system is becoming widespread and has changed diabetic practice. The working group bringing together a number of French experts has proposed the present practical consensus. Training of professionals and patient education are crucial for the success of CGM.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2017
Artificial Pancreas (AP) are developed for patients with Type 1 diabetes. This medical device system consists in the association of a subcutaneous continuous glucose monitor (CGM) providing a proxy of the patient's glycaemia and a control algorithm offering the real-time modification of the insulin delivery with an automatic command of the subcutaneous insulin pump. The most complex algorithms are based on a compartmental model of the glucoregulatory system of the patient coupled to an approach of MPC (Model-Predictive-Control) for the command.
View Article and Find Full Text PDFAim: The benefits of retrospective continuous glucose monitoring (retroCGM) recording have been widely explored in clinical studies, and many diabetes physicians routinely use this examination. However, the method of interpretation of CGM recordings has never been precisely described.
Method: An expert French panel of physicians met for two days to discuss several aspects of retroCGM use and to produce a position statement.
Background: Implanted insulin pumps using the peritoneal route provide long-term improvement of glucose control compared with subcutaneous insulin therapy in type 1 diabetes (T1D) patients. The stability of insulin preparation is critical for a safe use in implanted pumps. Insuman implantable(®) (400 IU/mL) (Sanofi-Aventis Deutschland GmbH, Frankfurt am Main, Germany), a recombinant human insulin, has been developed as a replacement for Insuplant(®) (Aventis Pharma, Frankfurt am Main, Germany), a semisynthetic insulin, the only one used so far.
View Article and Find Full Text PDFObjective: The benefits of real-time continuous glucose monitoring (CGM) have been demonstrated in patients with type 1 diabetes. Our aim was to compare the effect of two modes of use of CGM, patient led or physician driven, for 1 year in subjects with poorly controlled type 1 diabetes.
Research Design And Methods: Patients with type 1 diabetes aged 8-60 years with HbA(1c) ≥ 8% were randomly assigned to three groups (1:1:1).
This review discusses the most recent developments in insulin pump technology. The benefits of the insulin pump to patients with type 1 diabetes are recognized both for its metabolic effectiveness and its positive effects on quality of life. The current pumps are reliable, small and light, and are becoming more and more sophisticated.
View Article and Find Full Text PDFBackground: This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications.
Methods: We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weight, and diabetes complications status.
© LitMetric 2025. All rights reserved.