Publications by authors named "Saxer C"

Background & Aims: Parenteral nutrition (PN) can lead to high or even toxic exposure to aluminum (Al). We aimed to quantify concentrations of Al and other chemical elements of all-in-one (AIO) PN admixtures for adults prepared from commercial multichamber bags (Olimel® 5.7%, Omegaflex® special, SmofKabiven®, all with and without electrolytes) and vitamin and trace element additives over a 48-h period.

View Article and Find Full Text PDF

(1) Drug compatibility with all-in-one (AiO) parenteral nutrition (PN) admixtures is a very important pharmaceutical quality issue to be answered based on appropriate laboratory testing. We assessed voriconazole (V), a poorly water-soluble (logP ≈ 1) single-daily dosed antifungal drug monitored in patients and thus candidate for AiO PN admixing for convenient and safe patient care. We evaluated V compatibility and stability in AiO PN admixtures through adapted therapeutic drug monitoring method (drug stability) and visual microscopic emulsion stability by lipid droplets analysis improved by an automated microscopic digital assessment.

View Article and Find Full Text PDF

Background: Parenteral antiepileptic drugs are frequently used in critically ill patients for seizure control therapy or prevention. Many of these patients require additional parenteral nutrition (PN). Therefore, a parallel infusion of the frequently used antiepileptic drug levetiracetam (LEV) is interesting in terms of the restricted i.

View Article and Find Full Text PDF

We present a technique for improved carrier generation by eliminating the instability of a mechanical device in favor of an electro-optical phase modulator in the reference arm of an optical coherence tomography system. A greater than threefold reduction in the phase variance between consecutive A-line scans at a repetition rate of 1 kHz was achieved. Stable and reproducible interference fringe generation permits phase-resolved digital data processing.

View Article and Find Full Text PDF

We used a novel phase-resolved optical Doppler tomographic (ODT) technique with very high flow-velocity sensitivity (10microm/s) and high spatial resolution (10microm) to image blood flow in port-wine stain (PWS) birthmarks in human skin. In addition to the regular ODT velocity and structural images, we use the variance of blood flow velocity to map the PWS vessels. Our device combines ODT and therapeutic systems such that PWS blood flow can be monitored in situ before and after laser treatment.

View Article and Find Full Text PDF

A high-speed single-mode fiber-based polarization-sensitive optical coherence tomography (PS OCT) system was developed. With a polarization modulator, Stokes parameters of reflected flight for four input polarization states are measured as a function of depth. A phase modulator in the reference arm of a Michelson interferometer permits independent control of the axial scan rate and carrier frequency.

View Article and Find Full Text PDF

We have developed a novel phase-resolved optical coherence tomography (OCT) and optical Doppler tomography (ODT) system that uses phase information derived from a Hilbert transformation to image blood flow in human skin with fast scanning speed and high velocity sensitivity. Using the phase change between sequential scans to construct flow-velocity imaging, this technique decouples spatial resolution and velocity sensitivity in flow images and increases imaging speed by more than 2 orders of magnitude without compromising spatial resolution or velocity sensitivity. The minimum flow velocity that can be detected with an axial-line scanning speed of 400 Hz and an average phase change over eight sequential scans is as low as 10 microm/s, while a spatial resolution of 10 microm is maintained.

View Article and Find Full Text PDF

Valsartan is known to be excreted largely as unchanged compound and is minimally metabolized in man. Although the only notable metabolite is 4-hydroxyvaleryl metabolite (4-OH valsartan), the responsible enzyme has not been clarified at present. The current in vitro studies were conducted to identify the cytochrome P450 (CYP) enzymes involved in the formation of 4-OH valsartan.

View Article and Find Full Text PDF

A simple and rapid assay is described for the simultaneous analysis of levodopa (l-DOPA) and 3-O-methyldopa (3-OMD) in human plasma samples, applying an ion-pair reversed-phase liquid chromatographic method with electrochemical detection, designed for clinical trials performed to study the effect of peripheral catechol-O-methyltransferase inhibitors on the metabolism of l-DOPA. After protein precipitation of 100 microl plasma sample aliquots with perchloric acid, the analytes are directly injected, separated within 10 min and simultaneously quantified down to 20 ng/ml by an electrochemical detector equipped with a dual-electrode system operating in redox mode eliminating effectively potential endogenous and exogenous interferences. The intra-assay precision for l-DOPA and 3-OMD was 1.

View Article and Find Full Text PDF

We report the first application of high-speed fiber-based polarization sensitive optical coherence tomography (PS-OCT) to image burned tissue in vivo. Thermal injury denatures collagen in skin and PS-OCT can measure the reduction in collagen birefringence using depth resolved changes in the polarization state of light propagated in, and reflected from, the tissue. Stokes vectors were calculated for each point in a scan and birefringence relative to incident polarization determined using four incident polarization states.

View Article and Find Full Text PDF

The present study analyzed the relationship between periodontal health adjacent to filled and unfilled tooth sites in young men (recruits). The status of oral health of 419 Swiss army recruits, aged 19 to 20 years was assessed by determining Plaque Index (PI), Retention Index (RI) and Gingival Index (GI) as well as Pocket Probing Depth (PPD) and Probing Attachment Loss (PAL). In addition, the level of alveolar bone was measured using digitized bite-wing radiographs with an enlargement of 4.

View Article and Find Full Text PDF

A simple gradient reversed-phase high-performance chromatographic method with ultraviolet detection for the determination of fluvastatin (FV) and its five metabolites, (M-2, M-3, M4, M-5 and M-7) in human plasma was developed and validated. The limit of quantification of FV and its five metabolites in human plasma was 10 ng ml(-1). The assay had satisfactory selectivity, recovery, linearity and precision accuracy.

View Article and Find Full Text PDF

This study investigates the role of gradient-index materials in the design of Cooke triplets for use as 35-mm format photographic objectives. Cooke triplet designs are presented with different types of gradient-index profiles. Both linear axial and shallow radial gradients are shown to provide effective control of spherical aberration and astigmatism.

View Article and Find Full Text PDF