Background: Zero-fluoroscopic pulsed field ablation (PFA) is the next step in advancing pulmonary vein isolation (PVI) for atrial fibrillation (AF).
Methods: A workflow incorporating a variable-loop circular PFA catheter, intracardiac echocardiography (ICE), and a visualized sheath was applied to 15 paroxysmal AF patients.
Results: It consisted of three steps: (1) positioning a non-magnetic mapping catheter in the coronary sinus after creating a right atrial matrix, (2) transseptal puncture with the sheath advancement to the left atrium under ICE guidance, and (3) PFA confirming catheter-tissue contact with tissue proximity indication.
Background: Identification of infrequent nonpulmonary vein trigger premature atrial contractions (PACs) is challenging. We hypothesized that pace mapping (PM) assessed by correlation scores calculated by an intracardiac pattern matching (ICPM) module was useful for locating PAC origins, and conducted a validation study to assess the accuracy of ICPM-guided PM.
Methods: Analyzed were 30 patients with atrial fibrillation.
Background: The effects of the patient's disease awareness on the management of postablation of atrial fibrillation (AF) are unknown.
Methods: One hundred thirty-three AF patients undergoing an initial ablation were given a disease awareness questionnaire with a score of 16 points (8 points about AF in general and 8 points about oral anticoagulants) for the Jessa Atrial Fibrillation Knowledge Questionnaire (JAKQ) before and 1-year-after ablation. We divided them into the poor disease awareness group and good disease awareness group according to the median value (75%) of the total JAKQ score about AF in general, and compared the baseline patient characteristics and the 1-year changes in the JAKQ score, medication adherence, blood pressure, laboratory data, echocardiographic parameters, and AF/atrial tachycardia (AT) recurrence rate between the two groups.
Background: Ablation strategies and modalities for atrial fibrillation (AF) have transitioned over the past decade, but their impact on post-ablation medication and clinical outcomes remains to be fully investigated.
Methods: We divided 682 patients who had undergone AF ablation in 2014-2019 (420 paroxysmal AFs [PAF], 262 persistent AFs [PerAF]) into three groups according to the period, that is, the 2014-2015 ( = 139), 2016-2017 ( = 244), and 2018-2019 groups ( = 299), respectively.
Results: Persistent AF became more prevalent and the left atrial (LA) diameter larger over the 6 years.
Background: A subeustachian pouch (SEP) often hinders the completion of a cavotricuspid isthmus (CTI) ablation of typical atrial flutter (AFL) and sometimes causes steam-pops during a power-controlled ablation. We hypothesized that real-time bull's-eye monitoring of the catheter surface temperature might be useful to locate the SEP where the temperature can rise rapidly, and a temperature-controlled ablation might avoid steam pops. This study aimed to demonstrate this hypothesis.
View Article and Find Full Text PDF