Although pulmonary vein isolation (PVI) has become the cornerstone ablation procedure for atrial fibrillation (AF), the optimal ablation procedure for persistent and long-standing persistent AF remains elusive. Targeting spatio-temporal electrogram dispersion in a tailored procedure has been suggested as a potentially beneficial alternative to a conventional PVI-only procedure. In this multicenter, randomized, controlled, double-blind, superiority trial, patients with drug-refractory persistent AF were randomly assigned to a tailored ablation procedure targeting areas of spatio-temporal dispersion, as detected by an artificial intelligence (AI) algorithm, in addition to PVI (tailored arm, n = 187, 23% women) or to a conventional PVI-only procedure (anatomical arm, n = 183, 19% women).
View Article and Find Full Text PDFBackground: Oral anticoagulation is recommended after ablation for atrial fibrillation among patients at high risk for stroke. Left atrial appendage closure is a mechanical alternative to anticoagulation, but data regarding its use after atrial fibrillation ablation are lacking.
Methods: We conducted an international randomized trial involving 1600 patients with atrial fibrillation who had an elevated score (≥2 in men and ≥3 in women) on the CHADS-VASc scale (range, 0 to 9, with higher scores indicating a greater risk of stroke) and who underwent catheter ablation.
Background: High-frequency, low-tidal volume (HFLTV) ventilation increases the efficacy and efficiency of radiofrequency catheter ablation (RFCA) of paroxysmal atrial fibrillation. Whether those benefits can be extrapolated to RFCA of persistent atrial fibrillation (PeAF) is undetermined.
Objective: The purpose of this study was to evaluate whether using HFLTV ventilation during RFCA in patients with PeAF is associated with improved procedural and long-term clinical outcomes compared to standard ventilation (SV).
Background: CONVERGE was a prospective, multicenter, randomized controlled trial that evaluated the safety of Hybrid Atrial Fibrillation Convergent (HC) and compared its effectiveness to endocardial catheter ablation (CA) for the treatment of persistent atrial fibrillation (PersAF) and longstanding PersAF (LSPAF). In 2020, we reported that CONVERGE met its primary safety and effectiveness endpoints. The primary objective of the present study is to report CONVERGE trial results for quality of life (QOL) and Class I/III anti-arrhythmic drug (AAD) utilization following HC.
View Article and Find Full Text PDFIntroduction: The prospective, nonrandomized, multicenter Q-FFICIENCY study demonstrated the safety and 12-month efficacy of paroxysmal atrial fibrillation (AF) ablation with the novel QDOT MICRO temperature-controlled, contact force-sensing, radiofrequency (RF) catheter. Participants underwent pulmonary vein isolation with very high-power short-duration (vHPSD) mode (90 W, ≤4 s) alone or combined with conventional-power temperature-controlled (CPTC) mode (25-50 W). This study aimed to assess quality-of-life (QOL) and healthcare utilization (HCU) benefits experienced by Q-FFICIENCY study participants.
View Article and Find Full Text PDFBackground: High-frequency, low-tidal-volume (HFLTV) ventilation is a safe and simple strategy to improve catheter stability and first-pass isolation during pulmonary vein (PV) isolation. However, the impact of this technique on long-term clinical outcomes has not been determined.
Objectives: This study sought to assess acute and long-term outcomes of HFLTV ventilation compared with standard ventilation (SV) during radiofrequency (RF) ablation of paroxysmal atrial fibrillation (PAF).
Background: Same-day discharge (SDD) after catheter ablation of atrial fibrillation (AF) has been widely adopted. Nevertheless, planned SDD has been performed by using subjective criteria rather than standardized protocols.
Objectives: The goal of this study was to determine the efficacy and safety of the previously described SDD protocol in a prospective multicenter study.
Background: Favorable clinical outcomes are difficult to achieve in long-standing persistent atrial fibrillation (LSPAF) with catheter ablation (CA). The CONVERGE (Convergence of Epicardial and Endocardial Ablation for the Treatment of Symptomatic Persistent Atrial FIbrillation) trial evaluated the effectiveness of hybrid convergent (HC) ablation vs endocardial CA.
Objective: The study sought to evaluate the safety and effectiveness of HC vs CA in the LSPAF subgroup from the CONVERGE trial.
Background: QDOT MICRO (QDM) is a novel contact force-sensing catheter optimized for temperature-controlled radiofrequency (RF) ablation. The very high-power short-duration (vHPSD) algorithm modulates power, maintaining target temperature during 90 W ablations for ≤4 seconds.
Objectives: This study aims to evaluate safety and 12-month effectiveness of the QDM catheter in paroxysmal atrial fibrillation (AF) ablation using the vHPSD mode combined with conventional-power temperature-controlled (CPTC) mode.
Background: Patients with wire and catheter refractory venous occlusion are traditionally referred for pectoral transvenous lead extraction (TLE) to obtain venous access. TLE causes 1-2 mm circumferential mechanical or laser destruction of tissue surrounding the lead(s). This not only exposes the patient to the risk of major complications but also can damage nontargeted leads.
View Article and Find Full Text PDFBackground: Left ventricular (LV) endocardial pacing is a promising method to deliver cardiac resynchronization therapy (CRT). WiSE-CRT is a wireless LV endocardial pacing system, and delivers ultrasonic energy to an LV electrode.
Objective: The purpose of this study was to present short-term outcomes with the WiSE-CRT system in centers with no prior implanting experience.
Purpose: Catheter ablation has become a mainstay therapy for atrial fibrillation (AF) with rapid innovation over the past decade. Variability in ablation techniques may impact efficiency, safety, and efficacy; and the ideal strategy is unknown. Real-world evidence assessing the impact of procedural variations across multiple operators may provide insight into these questions.
View Article and Find Full Text PDFBackground: The limited effectiveness of endocardial catheter ablation (CA) for persistent and long-standing persistent atrial fibrillation (AF) treatment led to the development of a minimally invasive epicardial/endocardial ablation approach (Hybrid Convergent) to achieve a more comprehensive lesion set with durable transmural lesions. The multicenter randomized controlled CONVERGE trial (Convergence of Epicardial and Endocardial Ablation for the Treatment of Symptomatic Persistent AF) evaluated the safety of Hybrid Convergent and compared its effectiveness to CA for persistent and long-standing persistent AF treatment.
Methods: One-hundred fifty-three patients were randomized 2:1 to Hybrid Convergent versus CA.
Atrial fibrillation is the most common sustained arrhythmia affecting over 33 million people worldwide. Approximately 70% of AF patients have non-paroxysmal AF. As AF progresses from paroxysmal to non-paroxysmal forms, the prevalence of comorbidities increases.
View Article and Find Full Text PDFIntroduction: This report presents safety data on the use of a new open-irrigation radiofrequency ablation (RFA) catheter with a 56-hole porous tip in 742 patients enrolled in 2 US prospective, multicenter observational registry studies representing real-world use of the catheter.
Methods: This analysis is comprised of patients who underwent RFA of drug-refractory recurrent symptomatic paroxysmal atrial fibrillation (AF). Acute adverse events (AEs) were collected and categorized by seriousness, timing, and relatedness, with 7 days of follow-up data in one study and at least 120 days of data from a 1-year follow-up in the other.
Implantation of a subcutaneous array to improve the defibrillation threshold of an existing transvenous defibrillation lead system without the need for lead extraction is discussed.
View Article and Find Full Text PDF