Motivation: Online adaptive radiotherapy with Ethos is based on the anatomy determined from daily cone beam computed tomography (CBCT) images. Dose optimization and computation are performed on the density map of a synthetic CT (sCT), a deformable registration of the initial planning CT (pCT) onto the current CBCT. Large density changes as present in the lung region are challenging the system.
View Article and Find Full Text PDFCranial stereotactic irradiations require accurate reproduction of the planning CT patient position at the time of treatment, including removal of rotational offsets. A device prototype was evaluated for potential clinical use to correct rotational positional offsets in image-guided radiotherapy workflow. Analysis was carried out with a prototype device "RPS head" by gKteso GmbH, rotatable up to 4° in three dimensions by hand wheels.
View Article and Find Full Text PDFJ Appl Clin Med Phys
December 2023
Purpose: Secondary dose calculation (SDC) with an independent algorithm is one option to perform plan-specific quality assurance (QA). While measurement-based QA can potentially detect errors in plan delivery, the dose values are typically only compared to calculations on homogeneous phantom geometries instead of patient CT data. We analyzed the sensitivity and specificity of an SDC software by purposely introducing different errors and determined thresholds for optimal decisions.
View Article and Find Full Text PDFBackground: Beam data commissioning is a core task of radiotherapy physicists. Despite multiple detectors available, a feasible measurement program compromises between detector properties and time constraints. Therefore, it is important to understand how nonideal measurement data propagates into patient dose calculation.
View Article and Find Full Text PDFPurpose: Ethos allows online adaption of radiotherapy treatment plans. Dose is calculated on synthetic computed tomographies (sCT), CT-like images generated by deforming planning CTs (pCT) onto daily cone beam CTs (CBCT) acquired during treatment sessions. Errors in sCT density distribution may lead to dose calculation errors.
View Article and Find Full Text PDFBackground: The response of various detectors in the radiotherapy energy range has been investigated, especially for 6 and 10 MV energies for small fields, and is summarized in TRS-483. However, data for accelerator energies above 10 MV are sparse or unavailable for many detectors, especially for the energy of 18 MV. Small variations in field output factors for the commissioning of a treatment planning system can have a high impact on calculation of dose distributions.
View Article and Find Full Text PDFPurpose: Developed as a plan-specific pre-treatment QA tool, Varian portal dosimetry promises a fast, high-resolution, and integrated QA solution. In this study, the agreement between predicted fluence and measured cumulative portal dose was determined for the first 140 patient plans at our Halcyon linear accelerator. Furthermore, the capability of portal dosimetry to detect incorrect plan delivery was compared to that of a common QA phantom.
View Article and Find Full Text PDFPurpose: The aim of this work was to test the implementation of small field dosimetry following TRS-483 and to develop quality assurance procedures for the experimental determination of small field output factors (SFOFs).
Materials And Methods: Twelve different centers provided SFOFs determined with various detectors. Various linac models using the beam qualities 6 MV and 10 MV with flattening filter and without flattening filter were utilized to generate square fields down to a nominal field size of 0.
Purpose: Any Linac will show geometric imprecisions, including non-ideal alignment of the gantry, collimator and couch axes, and gantry sag or wobble. Their angular dependence can be quantified and resulting changes of the dose distribution predicted (Wack, JACMP 20(5), 2020). We analyzed whether it is feasible to correct geometric shifts during treatment planning.
View Article and Find Full Text PDFBackground: To implement a tangential treatment technique for whole breast irradiation using the Varian Halcyon and to compare it with Elekta Synergy Agility plans.
Methods: For 20 patients two comparable treatment plans with respect to dose coverage and normal tissue sparing were generated. Tangential field-in-field treatment plans (Pinnacle/Synergy) were replanned using the sliding window technique (Eclipse/Halcyon).
Purpose: A signal dependence on dose rate was reported for the ArcCHECK array due to recombination processes within the diodes. The purpose of our work was to quantify the necessary correction and apply them to quality assurance measurements.
Methods: Static 10 × 10 cm 6-MV fields delivered by a linear accelerator were applied to the detector array while decreasing the average dose rate, that is, the pulse frequency, from 500 to 30 MU/min.
Small-field dosimetry used in advance treatment technologies poses challenges due to loss of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and the limited choice of suitable radiation detectors. These challenges greatly influence dosimetric accuracy. Many high-profile radiation incidents have demonstrated a poor understanding of appropriate methodology for small-field dosimetry.
View Article and Find Full Text PDFPurpose: To assess the impact of isocenter shifts due to linac gantry and table rotation during cranial stereotactic radiosurgery on D , target volume coverage (TVC), conformity (CI), and gradient index (GI).
Methods: Winston-Lutz (WL) checks were performed on two Elekta Synergy linacs. A stereotactic quality assurance (QA) plan was applied to the ArcCHECK phantom to assess the impact of isocenter shift corrections on Gamma pass rates.
Background: Idarucizumab is a monoclonal antibody fragment with high affinity for dabigatran reversing its anticoagulant effects within minutes. Thereby, patients with acute ischemic stroke who are on dabigatran treatment may become eligible for thrombolysis with recombinant tissue-type plasminogen activator (rt-PA). In patients on dabigatran with intracerebral hemorrhage idarucizumab could prevent lesion growth.
View Article and Find Full Text PDFPurpose: The model used to calculate dose distributions in a radiotherapy treatment plan relies on the data entered during beam commissioning. The quality of these data heavily depends on the detector choice made, especially in small fields and in the buildup region. Therefore, it is necessary to identify suitable detectors for measurements in the buildup region of small fields.
View Article and Find Full Text PDFFor any detector to be used for the determination of absorbed dose at the point of measurement in water a basic equation is required to convert the reading of the detector into absorbed dose in water. The German DIN 6800 part 1 provides a general formalism for that. A further differentiated formalism applicable to photon dosimetry is suggested in this work.
View Article and Find Full Text PDFPurpose: The effective point of measurement (EPOM) of cylindrical ionization chambers differs from their geometric center. The exact shift depends on chamber construction details, above all the chamber size, and to some degree on the field-size and beam quality. It generally decreases as the chamber dimensions get smaller.
View Article and Find Full Text PDFThe 3D-dose module (3DVH) of the ArcCHECK-phantom reconstructs the dose distribution in the phantom volume and transfers it to the patient geometry. Our aim was to evaluate the 3DVH-reconstructed dose systematically building up from simple to complex cases. Therefore, the influence of different field sizes without and with blocking the isocenter was tested.
View Article and Find Full Text PDFRelative dose measurements with small ionization chambers in combination with an electrometer placed in the treatment room ("internal electrometer") show a large dependence on the polarity used. While this was observed previously for percent depth dose curves (PDDs), the effect has not been understood or preventable. To investigate the polarity dependence of internal electrometers used in conjunction with a small-volume ionization chamber, we placed an internal electrometer at a distance of 1 m from the isocenter and exposed it to different amounts of scattered radiation by varying the field size.
View Article and Find Full Text PDFPurpose: The integral quality monitor (IQM) transmission detector is a wedge-shaped large area ionization chamber that reports a position-weighted dose area product for each control point of an IMRT or VMAT plan. In this study, the accuracy of the signal prediction is verified for the Synergy Agility MLC. Tolerance criteria for VMAT plan verification with the IQM were obtained from the observed sensitivity for the detection of incorrectly delivered plans.
View Article and Find Full Text PDFPurpose: The characteristics of radiation detectors have to be assessed for dosimetry in the presence of magnetic fields, i.e. in conditions found in combined machines for magnetic resonance imaging and radiotherapy.
View Article and Find Full Text PDFBackground: In Germany, intoxications cause the bulk of emergencies in children, to be prevented or attenuated by preventive measures. Therefore, knowledge about intoxications is essential for pediatricians. The present work provides general and epidemiologic data about intoxications and most frequent categories and single toxicants.
View Article and Find Full Text PDF