Publications by authors named "Satoshi Miyajima"

Nucleus ruber is known as an important supraspinal center that controls forelimb movements in tetrapods, and the rubral homologue may serve similar functions in fishes (motor control of pectoral fin). However, two apparently different structures have been identified as 'nucleus ruber' in actinopterygians. One is nucleus ruber of Goldstein (1905) (NRg), and the other nucleus ruber of Nieuwenhuys and Pouwels (1983) (NRnp).

View Article and Find Full Text PDF

A new treatment planning system (TPS) was designed and developed for a new treatment system, which consisted of a micro-beam-enabled linac with robotics and a real-time tracking system. We also evaluated the effectiveness of the implemented algorithms of optimization and dose calculations in the TPS for the new treatment system. In the TPS, the optimization procedure consisted of the pseudo Beam's-Eye-View method for finding the optimized beam directions and the steepest-descent method for determination of beam intensities.

View Article and Find Full Text PDF

The results of Monte Carlo calculated dose distributions of proton treatment of ocular melanoma are presented. An efficient spot scanning method utilizing active energy modulation, which also minimizes the number of target spots was developed. We simulated various parameter values for the particle energy spread and the pencil beam diameter in order to determine values suitable for medical treatment.

View Article and Find Full Text PDF

A CdTe Schottky diode detector of 1 mm thickness was employed in diagnostic x-ray spectroscopy. The detector response to monoenergetic photons was investigated with gamma rays from the calibration sources (241Am and 133Ba). As spectral distortion due to carrier trapping, known as tailing, was small in gamma-ray spectra, the effects of carrier trapping were not taken into account in the calculation of response functions.

View Article and Find Full Text PDF

Purpose: A Monte Carlo (MC) model of CyberKnife was developed as a quality assurance tool. The percentage depth dose (%dd) was verified by using this model.

Materials And Methods: An MC model was developed with Electron Gamma Shower version 4 (EGS4) in two steps: (1) a model of the CyberKnife treatment head and (2) a model of the collimator and phantom.

View Article and Find Full Text PDF

A CdZnTe (CZT) detector was utilized in mammographic x-ray spectroscopy under clinical conditions. First, the detector response was investigated using y-rays from 241Am. The escape of secondary (Compton scattered and K fluorescent) x-rays and tailing due to carrier trapping were minor in the mammographic energy range.

View Article and Find Full Text PDF

A method to utilize CdZnTe (CZT) detectors in diagnostic x-ray spectroscopy is described in this article. Spectral distortion due to transmission of primary x rays, the escape of cadmium- and tellurium-K fluorescent x rays, and tailing was severe in measured x-ray spectra. Therefore, correction for the distortion was performed with the stripping method using response functions.

View Article and Find Full Text PDF