The application of low magnetic fields to heteronuclear NMR has expanded recently alongside the emergence of methods for achieving near unity polarization of spin ensembles, independent of magnetic field strength. The parahydrogen induced hyperpolarization methods in particular, often use a hybrid arrangement where a high field spectrometer is used to detect or image polarized molecules that have been conjured on a separate, dedicated polarizer instrument operating at fields in the mT regime where yields are higher. For controlling polarizer chemistry, spare TTL channels of portable NMR spectrometers can be used to pulse program reaction timings in synchrony with heteronuclear RF transformations.
View Article and Find Full Text PDFPurpose: Head motion continues to be a major source of artifacts and data quality degradation in MRI. The goal of this work was to develop and demonstrate a novel technique for prospective, 6 degrees of freedom (6DOF) rigid body motion estimation and real-time motion correction using inductively coupled wireless nuclear magnetic resonance (NMR) probe markers.
Methods: Three wireless probes that are inductively coupled with the scanner's RF setup serve as fiducials on the subject's head.
Purpose: To reconstruct accurate single- and multichannel Bloch-Siegert transmit radiofrequency (|B(1)(+)|) field maps from highly accelerated data.
Theory And Methods: The approach is based on the fact that the |B(1)(+)|-to-phase encoding pulse for each transmit coil and off-resonance frequency applies a unique phase shift to the same underlying image. This enables joint reconstruction of all images in a Bloch-Siegert acquisition from an augmented set of virtual receive coils, using any autocalibrated parallel imaging reconstruction method.
Applications of PASADENA in biomedicine are continuing to emerge due to recent demonstrations that hyperpolarized metabolic substrates and the corresponding reaction products persist sufficiently long to be detected in vivo. Biomedical applications of PASADENA typically differ from their basic science counterparts in that the polarization endowed by addition of parahydrogen is usually transferred from nascent protons to coupled storage nuclei for subsequent detection on a higher field imaging instrument. These pre-imaging preparations usually take place at low field, but commercial spectrometers capable of heteronuclear pulsed NMR at frequencies in the range of 100 kHz to 1 MHz are scarce though, in comparison to single channel consoles in that field regime.