Introduction: This work describes the clinical implementation of a Monte Carlo based platform for treatment plan validation for Tomotherapy and Cyberknife, including a semi-automatic plan evaluation module based on dose constraints for organs-at-risk (OAR).
Methods: The Monte Carlo-based platform Moderato [1] is based on BEAMnrc/DOSXYZnrc and allows for automated re-calculation of doses planned with Tomotherapy and Cyberknife techniques. The Prescription/Validation module generates a set of dose constraints based on the anatomical region and fractionation scheme considered.
Purpose: The main focus of the current paper is the clinical implementation of a Monte Carlo based platform for treatment plan validation for Tomotherapy and Cyberknife, without adding additional tasks to the dosimetry department.
Methods: The Monte Carlo platform consists of C++ classes for the actual functionality and a web based GUI that allows accessing the system using a web browser. Calculations are based on BEAMnrc/DOSXYZnrc and/or GATE and are performed automatically after exporting the dicom data from the treatment planning system.
The poor prognosis of children with high-grade glioma (HGG) and high-risk neuroblastoma, despite multidisciplinary therapeutic approaches, demands new treatments for these indications. F14512 is a topoisomerase II inhibitor containing a spermine moiety that facilitates selective uptake by tumor cells via the Polyamine Transport System (PTS) and increases topoisomerase II poisoning. Here, F14512 was evaluated in pediatric HGG and neuroblastoma cell lines.
View Article and Find Full Text PDFNumerous tumour types can occur in the pineal region. Because these tumours are uncommon and heterogeneous, it is often difficult to establish optimal treatment strategies based on comparative clinical trials. To date, the role of radiosurgery for the treatment of pineal region tumours remains controversial.
View Article and Find Full Text PDFBackground: Head and Neck Squamous Cell Carcinoma (HNSCC) is the sixth most common cancer worldwide. The treatment of advanced stages HNSCC is based on surgical treatment combined with radiotherapy and chemotherapy or concomitant chemo-radiotherapy. However, the 5-year survival remains poor for advanced stages HNSCC and the development of new targeted therapies is eagerly awaited.
View Article and Find Full Text PDFThe prognosis of children with high-grade glioma or high-risk neuroblastoma remains poor. Cilengitide is a selective antagonist of αvβ3 and αvβ5 integrins, which are involved in tumor growth and development of metastasis. We have evaluated the effects of cilengitide on pediatric glioma and neuroblastoma cell lines for the first time.
View Article and Find Full Text PDFIn the field of radiation oncology, equipment for fractionated radiotherapy and single-dose radiosurgery has become increasingly accurate, together with the introduction of robotized treatments. A robot is a device that can be programmed to carry out accurate, repeated and adjusted tasks in a given environment. Treatment of extracranial lesions involves taking into account organ mobility (tumor and healthy tissue) whilst retaining the ability to stereotactically locate the target.
View Article and Find Full Text PDFRadiation therapy (RT) is an established treatment modality for malignant neoplasms. RT induces tissue damage that may lead to osteoradionecrosis in more severe cases. Suitable animal models to study RT-induced changes in membranous craniofacial bone are currently not available.
View Article and Find Full Text PDFObject: Stereotactic radiosurgery is an increasingly used, and the least invasive, surgical option for patients with trigeminal neuralgia (TN). In this study, the authors performed a retrospective evaluation of the safety and efficacy of this method for idiopathic TN.
Methods: The authors reviewed data from 76 patients with idiopathic TN who underwent Gamma Knife surgery (GKS).
In 2006, 3 sites have been selected by the Institut national of cancer (Lille, Nancy et Nice) to evaluate a radiotherapy robot, the CyberKnife. This machine, able to track mobile tumours in real time, gives new possibilities in the field of extra cranial stereotactic radiotherapy. Functionalities and medico economical issues of the machine will be evaluated during 2 years on the 3 sites.
View Article and Find Full Text PDFA phase I trial was initiated to establish the dose-limiting toxicities (DLTs) and the maximum tolerated dose (MTD) of chronomodulated 5-fluorouracil and cisplatin given concurrently with preoperative radiotherapy in patients with esophageal cancer. Patients with stage I or II esophageal cancer received preoperative radiation therapy (28-30 daily 1.8-Gy fractions for a total of 50.
View Article and Find Full Text PDFIntroduction: Verification of absorbed dose in target volume is a key factor for quality assurance in radiotherapy. In vivo measurements allow evaluation of the variations in dose with time and variations between measured doses and calculated doses by TPS. The aim of this work were to evaluate reproducibility of patient positioning and to compare calculated doses by 2 different TPS.
View Article and Find Full Text PDFPurpose: We prospectively compared a conventional treatment planning (PT2D) and 3-dimensional conformal treatment planning (PT3D) for radiotherapy of cerebral tumours.
Patients And Methods: Patients treated between 1/10/98 and 1/4/99 by irradiation for cerebral tumours were analysed. For each case, we planned PT2D using conventional orthogonal x-ray films, and afterward, PT3D using CT scan.
Typical dosimeters used in stereotactic radiation therapy, such as ionization chambers, films, and thermoluminescent diodes, allow basic physical measurements. They are, however, neither well suited to discern small target volumes with high dose gradient, nor suitable for three-dimensional (3D) dose measurements. Gel dosimetry is becoming more and more interesting, owing to magnetic resonance imaging (MRI).
View Article and Find Full Text PDFPurpose: Retrospective analysis of the results obtained with daily interactive use of portal imaging for monitoring thoracic cancer radiotherapy.
Materials And Methods: A Siemens electronic portal imaging system called Beamviewplus was used daily in 15 lung cancer patients for each X-ray field. Out of the 714 expected portal images, 585 (82%), were obtained and printed.
An agarose gel phantom is used to evaluate the spatial distribution of the dose delivered by a linac radiosurgery device. Dependence of the absorbed dose on the T1 relaxation time is checked. T1 magnetic resonance images show the close correspondence between the actual absorbed dose distribution and the dose distribution expected by the treatment planning.
View Article and Find Full Text PDF