Publications by authors named "Sarit L Kaserzon"

Wastewater treatment plants (WWTPs) have been recognized as secondary sources of per- and polyfluoroalkyl substances (PFAS) released into the environment. In this study, PFAS concentrations were measured in effluent and biosolids samples collected from 75 WWTPs across Australia during the 2016 Census period, which covers more than half of the Australian population. Twelve PFAS compounds, including six C5-C10 perfluoroalkyl carboxylic acids (PFCAs), four perfluoro sulfonic acids (PFSAs) such as perfluorobutane sulfonate (PFBS), perfuorohexane sulfonic (PFHxS), perfluorooctane sulfonic acid (PFOS), and perfluorodecane sulfonic acid (PFDS), and one fluorotelomer sulfonic acid (6:2 FTS), were detected in the effluent, with concentrations up to 504 ng/L (PFHxS).

View Article and Find Full Text PDF

The quality of chemical analysis is an important aspect of passive sampling-based environmental assessments. The present study reports on a proficiency testing program for the chemical analysis of hydrophobic organic compounds in silicone and low-density polyethylene (LDPE) passive samplers and hydrophilic compounds in polar organic chemical integrative samplers. The median between-laboratory coefficients of variation (CVs) of hydrophobic compound concentrations in the polymer phase were 33% (silicone) and 38% (LDPE), similar to the CVs obtained in four earlier rounds of this program.

View Article and Find Full Text PDF

Monitoring contamination from per- and polyfluoroalkyl substances (PFASs) in water systems impacted by aqueous film-forming foams (AFFFs) typically addresses a few known PFAS groups. Given the diversity of PFASs present in AFFFs, current analytical approaches do not comprehensively address the range of PFASs present in these systems. A suspect-screening and nontarget analysis (NTA) approach was developed and applied to identify novel PFASs in groundwater samples contaminated from historic AFFF use.

View Article and Find Full Text PDF

The use of peak-picking algorithms is an essential step in all nontarget analysis (NTA) workflows. However, algorithm choice may influence reliability and reproducibility of results. Using a real-world data set, the aim of this study was to investigate how different peak-picking algorithms influence NTA results when exploring temporal and/or spatial trends.

View Article and Find Full Text PDF

Non-target analysis (NTA) using high-resolution mass spectrometry is becoming a useful approach to screen for suspect and unknown chemicals. For comprehensive analyses, data-independent acquisition (DIA), like Sequential Windowed Acquisition of all THeoretical Mass Spectra (SWATH-MS) on Sciex instruments, is necessary, usually followed by library matching for feature annotation. The choice of parameters, such as acquisition window number and size, may influence the comprehensiveness of the suspect features detected.

View Article and Find Full Text PDF

The leaching of per- and polyfluoroalkyl substances (PFASs) from Australian firefighting training grounds has resulted in extensive contamination of groundwater and nearby farmlands. Humans, farm animals, and wildlife in these areas may have been exposed to complex mixtures of PFASs from aqueous film-forming foams (AFFFs). This study aimed to identify PFAS classes in pooled whole blood ( = 4) and serum ( = 4) from cattle exposed to AFFF-impacted groundwater and potentially discover new PFASs in blood.

View Article and Find Full Text PDF

L'Albufera Natural Park (Valencia, Spain) is a protected wetland of international significance that provides critical habitats to endemic and threatened bird and plant species. This study aims to use multiple cross-validation techniques to generate an accurate estimation of the environmental risk of organic contaminants (OCs) in an internationally important coastal wetland, to identify compounds of concern and their potential sources and risk factors. Microporous polyethylene tube (MPT) passive samplers were deployed at 12 locations across L'Albufera Natural Park with concurrent grab samples collected.

View Article and Find Full Text PDF

Wastewater-based epidemiology (WBE) relies on representative sampling that is typically achieved with autosamplers that collect time, flow, or volume proportional samples. The expense, resources and operational know-how associated with autosampler operation means they are only typically available at major wastewater treatment plants (WWTPs). This results in a lack of data on consumption levels in regional and remote areas, or in countries that lack the financial means.

View Article and Find Full Text PDF

As Europe's second longest river, the Danube is an important water source for drinking water and irrigation for many countries, before discharging into the Black Sea in the East. Per- and poly-fluoroalkyl substances (PFAS) have been observed over the last two decades in concentrations exceeding the European Union's drinking water guidelines for total sum of 20 select PFAS of 0.1 μg L.

View Article and Find Full Text PDF

Water resources are vulnerable to contamination from polar organic compounds (POCs) originating from sources such as wastewater effluent. Two configurations of a microporous polyethylene tube (MPT) passive sampler were investigated for the time-integrative detection and quantification of POCs in effluent. One configuration contained the polymeric reversed phase sorbent Strata-X (SX) and the other Strata-X suspended in agarose gel (SX-Gel).

View Article and Find Full Text PDF

Nanoplastics (NPs; <1 μm) have greater availability to marine organisms than microplastics (1-5000 μm). Understanding NP uptake and depuration in marine organisms intended for human consumption is imperative for food safety, but until now it has been limited due to analytical constraints. Oysters () were exposed to polystyrene NPs doped with palladium (Pd), allowing the measurements of their uptake into tissues by inductively coupled plasma mass spectrometry (ICP-MS) combined with electron microscopy.

View Article and Find Full Text PDF

This study investigated the mobilization of a wide range of per- and polyfluoroalkyl substances (PFASs) present in aqueous film-forming foams (AFFFs) in water-saturated soils through one-dimensional (1-D) column experiments with a view to assessing the feasibility of their remediation by soil desorption and washing. Results indicated that sorption/desorption of most of the shorter-carbon-chain PFASs ( ≤ 6) in soil reached greater than 99% rapidly─after approximately two pore volumes (PVs) and were well predicted by an equilibrium transport model, indicating that they will be readily removed by soil washing technologies. In contrast, the equilibrium model failed to predict the mobilization of longer-chain PFASs ( ≥ 7), indicating the presence of nonequilibrium sorption/desorption (confirmed by a flow interruption experiment).

View Article and Find Full Text PDF

Monitoring SARS-CoV-2 RNA in sewer systems, upstream of a wastewater treatment plant, is an effective approach for understanding potential COVID-19 transmission in communities with higher spatial resolutions. Passive sampling devices provide a practical solution for frequent sampling within sewer networks where the use of autosamplers is not feasible. Currently, the design of upstream sampling is impeded by limited understanding of the fate of SARS-CoV-2 RNA in sewers and the sensitivity of passive samplers for the number of infected individuals in a catchment.

View Article and Find Full Text PDF

Passive sampling approaches to monitor licit and illicit drugs of concern in wastewater shows promise as a supplementary sampling technique to grab sampling when conventional composite autosampling may not be possible. Recent studies have assessed the applicability of passive sampling at a single wastewater treatment plant (WWTP). However, it remains unknown whether a single-site calibration can be applied to other WWTPs.

View Article and Find Full Text PDF

Hexa(methoxymethyl)melamine (HMMM) is commonly used as a cross-linking agent in coatings and as a vulcaniser in tyre production to increase the durability of tyres. Early reports of elevated aquatic concentrations of HMMM and a range of co-occurring cyclic amines have been linked to toxicity and mortality events of aquatic organisms. There are currently only few studies reporting environmental concentrations of HMMM and the co-occurring cyclic amines, and this study reports the first environmental assessment in Australian surface waters.

View Article and Find Full Text PDF

New Zealand uses more than a ton of pesticides each year; many of these are mobile, relatively persistent, and can make their way into waterways. While considerable effort goes into monitoring nutrients in agricultural streams and programs exist to monitor pesticides in groundwater, very little is known about pesticide detection frequencies, concentrations, or their potential impacts in New Zealand streams. We used the 'Polar Organic Chemical Integrative Sampler' (POCIS) approach and grab water sampling to survey pesticide concentrations in 36 agricultural streams in Waikato, Canterbury, Otago and Southland during a period of stable stream flows in Austral summer 2017/18.

View Article and Find Full Text PDF

Untargeted analysis of a composite house dust sample has been performed as part of a collaborative effort to evaluate the progress in the field of suspect and nontarget screening and build an extensive database of organic indoor environment contaminants. Twenty-one participants reported results that were curated by the organizers of the collaborative trial. In total, nearly 2350 compounds were identified (18%) or tentatively identified (25% at confidence level 2 and 58% at confidence level 3), making the collaborative trial a success.

View Article and Find Full Text PDF

Per-and polyfluoroalkyl substances (PFASs) as key components in aqueous film forming foams (AFFF) have led to growing incidences of environmental contamination. The aim of this study was to investigate a novel diffusion based passive sampling device comprising of microporous polyethylene (PE) for the long-term time-integrative monitoring of PFASs in groundwater systems. PE passive samplers (PEs) were deployed for 83 d and calibrated at five AFFF impacted groundwater sites representing different PFASs concentration levels (ΣPFAS 0.

View Article and Find Full Text PDF

Wastewater samples were collected at the influent and effluent of two wastewater treatment plants (WWTPs) in Ho Chi Minh City, Vietnam and then pooled to daily samples over multiple days using 6 hourly grab samples. The aim was to provide a first assessment of the occurrence, consumption, removal and release of a range of organic chemicals including pharmaceuticals and personal care products (PPCPs), illicit drugs, an artificial sweetener, tobacco and its metabolites and alcohol biomarkers (referred to here as DPCPBs). Nineteen DPCPBs were detected via direct measurement of filtered wastewater on LC-MS/MS with a concentration range of 0.

View Article and Find Full Text PDF

Glyphosate (PMG) is one of the most widely used herbicides with a reported 8.6 million tons applied globally in 2016. Due to widespread use and limited understanding of long-term environmental impacts, it is expected that future monitoring requirements for PMG and its primary metabolite aminomethyl phosphonic acid (AMPA) in aquatic environments will increase, along with the need for low cost monitoring and risk assessment strategies.

View Article and Find Full Text PDF

Access to clean, safe drinking water poses a serious challenge to regulators, and requires analytical strategies capable of rapid screening and identification of potentially hazardous chemicals, specifically in situations when threats to water quality or security require rapid investigations and potential response. This study describes a fast and efficient chemical hazard screening strategy for characterising trace levels of polar organic contaminants in water matrices, based on liquid chromatography high resolution mass spectrometry with post-acquisition 'case-control' data processing. This method allowed for a rapid response time of less than 24 h for the screening of target, suspect and non-target unknown chemicals via direct injection analysis, and a second, more sensitive analysis option requiring sample pre-concentration.

View Article and Find Full Text PDF

Many transformation products (TPs) from organic micropollutants are not included in routine environmental monitoring programs due to limited knowledge of their occurrence and fate. An efficient method to identify and prioritize critical compounds in terms of environmental relevance is needed. In this study, we applied a strategic screening approach based on a case-control concept to identify TPs formed along wastewater-impacted rivers.

View Article and Find Full Text PDF

The suitability of passive samplers (Chemcatcher) as an alternative to grab sampling in estimating time-weighted average (TWA) concentrations and total loads of herbicides was assessed. Grab sampling complemented deployments of passive samplers in a tropical waterway in Queensland, Australia, before, during and after a flood event. Good agreement was observed between the two sampling modes in estimating TWA concentrations that was independent of herbicide concentrations ranging over 2 orders of magnitude.

View Article and Find Full Text PDF