Publications by authors named "Sarah H Van Tassel"

Article Synopsis
  • A study analyzed complications related to the Zeiss CT Lucia 602 intraocular lenses through FDA MAUDE reports, focusing on flanged scleral tunnel fixation techniques.
  • A total of 178 reports were reviewed, with the majority occurring in the last three years, highlighting lens tilt as the most prevalent issue, along with cases of breakage.
  • The findings indicate a significant rise in reported complications, especially intraoperatively, and reveal that haptic breakage poses a serious concern for these lenses in practical use.
View Article and Find Full Text PDF

Deep learning has enabled breakthroughs in automated diagnosis from medical imaging, with many successful applications in ophthalmology. However, standard medical image classification approaches only assess disease presence , neglecting the common clinical setting of longitudinal imaging. For slow, progressive eye diseases like age-related macular degeneration (AMD) and primary open-angle glaucoma (POAG), patients undergo repeated imaging over time to track disease progression and forecasting the future risk of developing a disease is critical to properly plan treatment.

View Article and Find Full Text PDF

To identify and describe adverse events (AEs) observed with real-world use of the following 3 vitrectomy platforms: Constellation (Alcon), Enhancing Visual Acuity (EVA, Dutch Ophthalmic Research Center), and Stellaris (Bausch + Lomb). All reports submitted to the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database between January 2010 and November 2021 that were associated with the 3 vitrectomy platforms were analyzed. Each report was reviewed for AEs or consequences and the type of complication noted.

View Article and Find Full Text PDF

Deep learning has enabled breakthroughs in automated diagnosis from medical imaging, with many successful applications in ophthalmology. However, standard medical image classification approaches only assess disease presence at the time of acquisition, neglecting the common clinical setting of longitudinal imaging. For slow, progressive eye diseases like age-related macular degeneration (AMD) and primary open-angle glaucoma (POAG), patients undergo repeated imaging over time to track disease progression and forecasting the future risk of developing a disease is critical to properly plan treatment.

View Article and Find Full Text PDF

Selective laser trabeculoplasty (SLT) has been in routine clinical use for over 20 years with millions of patients successfully treated and a low rate of clinically significant complications. The procedure requires the clinician to manually position the laser beam on the trabecular meshwork using a gonioscopy lens and to titrate the SLT laser energy based on the amount of pigmentation in the angle, as well as the observation of small bubbles produced by the laser effect. We propose that SLT energy titration is unnecessary either to achieve intraocular pressure (IOP) reduction or to minimize potential side effects.

View Article and Find Full Text PDF

Deep learning has become a popular tool for computer-aided diagnosis using medical images, sometimes matching or exceeding the performance of clinicians. However, these models can also reflect and amplify human bias, potentially resulting inaccurate missed diagnoses. Despite this concern, the problem of improving model fairness in medical image classification by deep learning has yet to be fully studied.

View Article and Find Full Text PDF

Purpose: Primary open-angle glaucoma (POAG) is one of the leading causes of irreversible blindness in the United States and worldwide. Although deep learning methods have been proposed to diagnose POAG, these methods all used a single image as input. Contrastingly, glaucoma specialists typically compare the follow-up image with the baseline image to diagnose incident glaucoma.

View Article and Find Full Text PDF

Primary open-angle glaucoma (POAG) is a leading cause of irreversible blindness worldwide. Although deep learning methods have been proposed to diagnose POAG, it remains challenging to develop a robust and explainable algorithm to automatically facilitate the downstream diagnostic tasks. In this study, we present an automated classification algorithm, GlaucomaNet, to identify POAG using variable fundus photographs from different populations and settings.

View Article and Find Full Text PDF

Prcis: Designed with novel features to facilitate implantation and improve safety, the Ahmed ClearPath (ACP) glaucoma drainage device (GDD) provided intraocular pressure (IOP) reduction comparable with other GDDs in eyes with refractory glaucoma in a multicenter retrospective study.

Purpose: To present clinical outcomes with a novel valveless GDD (ACP, New World Medical). The 250 and 350 mm2 models feature a contoured plate for optimal globe apposition, anteriorized suture points to facilitate suturing to the globe, and a prethreaded 4-0 polypropylene ripcord suture.

View Article and Find Full Text PDF

Retinopathy of prematurity (ROP) is a leading cause of childhood blindness that occurs due to incomplete development of retinal blood vessels in preterm infants. Glaucoma is an ocular comorbidity in some patients with ROP, and it may be associated with immature anterior chamber development, ROP itself, or the treatment for ROP. There have been a few reports of narrow-angle glaucoma after laser treatment for ROP.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to identify patients with glaucoma and corneal/ocular surface disease who have been fit with Prosthetic Replacement of the Ocular Surface Ecosystem (PROSE; BostonSight, Needham, MA) devices and to understand the PROSE device fit experience in patients with glaucoma at Weill Cornell Medicine (WCM).

Methods: This is a retrospective chart review of patients older than 18 years who underwent PROSE device fitting at WCM. Records were reviewed for demographic information and ophthalmic variables.

View Article and Find Full Text PDF

Prcis: Characteristics of the most mentioned glaucoma articles on the internet were analyzed, allowing a better understanding of the dissemination of glaucoma research to the general public.

Purpose: The aim was to determine the 100 most mentioned articles on the internet in the field of glaucoma and analyze their characteristics.

Materials And Methods: We identified the top 100 glaucoma articles with the highest Altmetric Attention Score (AAS), an automatically calculated metric for monitoring social media.

View Article and Find Full Text PDF

Purpose: To report real-world complications associated with femtosecond laser-assisted cataract surgery (FLACS).

Setting: Deidentified database.

Design: Retrospective review.

View Article and Find Full Text PDF

Purpose: To describe with multimodal imaging including the use of ultra-widefield optical coherence tomography imaging a distinct phenotype of autosomal recessive nanophthalmos associated with a novel mutation of the MFRP gene (membrane-type frizzled-related protein).

Methods: Case report of a single patient followed by the Weill Cornell Medicine Department of Ophthalmology Retina and Glaucoma Services, and review of the relevant literature.

Results: A patient with a novel homozygous mutation in the MFRP gene (c.

View Article and Find Full Text PDF

Purpose: To investigate the safety and tolerability of the multi-pressure dial (MPD) worn overnight for seven consecutive days.

Design: Prospective, open-label, randomized, single-site study.

Subjects: Twenty eyes of 10 subjects with open-angle glaucoma were fitted with an MPD and randomized to negative pressure application of -10 mmHg in one eye (study eye) worn overnight for 7 consecutive days.

View Article and Find Full Text PDF

Purpose: To report a hypopyon following selective laser trabeculoplasty (SLT).

Observations: An 85-year-old woman with primary open-angle glaucoma underwent routine SLT. In the early post-procedural period, she presented with pain and decreased vision, and she was found to have hypopyon, trabeculitis, and corneal edema.

View Article and Find Full Text PDF

Unlabelled: PRéCIS:: Publications in glaucoma have seen an increase in the number of authors and disclosures per article, authors with dual degrees, and international authors, but contributions of women to articles published remains low.

Purpose: Authorship trends have been studied across many medical specialties and in ophthalmology as a whole, but not specifically in glaucoma. The authors explored the authorship trends of original scientific articles in the Journal of Glaucoma.

View Article and Find Full Text PDF

Aim: To determine relationships between retinal nerve fiber layer (RNFL) thickness and nadir CD4 cell count in human immunodeficiency virus (HIV) positive patients evaluated for glaucoma suspicion.

Methods: Data were reviewed for 329 HIV positive patients evaluated for glaucoma suspicion. High-definition optical coherence tomography (OCT) RNFL measurements were obtained at least 6mo apart.

View Article and Find Full Text PDF