There are limited data to support proposed increases to the minimum institutional mitral valve (MV) surgery volume required to begin a transcatheter mitral valve repair (TMVr) program. The current study examined the association between institutional MV procedure volumes and outcomes. All 2017 Medicare fee-for-service patients who received a TMVr or MV surgery procedure were included and analyzed separately.
View Article and Find Full Text PDFBackground: In patients with implantable cardioverter-defibrillators, healthcare utilization (HCU) and expenditures related to shocks have not been quantified.
Methods And Results: We performed a retrospective cohort study of patients with implantable cardioverter-defibrillators identified from commercial and Medicare supplemental claims databases linked to adjudicated shock events from remote monitoring data. A shock event was defined as ≥1 spontaneous shocks delivered by an implanted device.
Several randomized trials and decision analysis models have found that remote monitoring may reduce health care utilization and expenditures in patients with cardiac implantable electronic devices (CIEDs), compared with in-office monitoring. However, little is known about the generalizability of these findings to unselected populations in clinical practice. To compare health care utilization and expenditures associated with remote monitoring and in-office monitoring in patients with CIEDs, we used Truven Health MarketScan Commercial Claims and Medicare Supplemental Databases.
View Article and Find Full Text PDFBackground: The incremental effects of risk factor combinations for atrial fibrillation (AF) and stroke are incompletely understood. We sought to quantify the risks of incident AF and stroke for combinations of established risk factors in a large US sample.
Methods And Results: Patients with no evidence of AF or stroke in 2007 were stratified by combinations of the following risk factors: heart failure, hypertension, diabetes, age 65 to 74, age ≥75, coronary artery disease, and chronic kidney disease.
Purpose: To examine imaging utilization in a matched cohort of patients with and without implantable cardioverter defibrillators (ICD) and to project magnetic resonance imaging (MRI) utilization over a 10-year period.
Materials And Methods: The Truven Health MarketScan Commercial claims and Medicare Supplemental health insurance claims data were used to identify patients with continuous health plan enrollment in 2009-2012. Patients with ICDs were identified using ICD-9 and CPT codes, and matched to patients with the same demographic and comorbidity profile, but no record of device implantation.