The potential of 3D selective laser melting (SLM) technology to produce compact, temperature and pressure stable titanium alloy chromatographic columns is explored. A micro bore channel (0.9 mm I.
View Article and Find Full Text PDFA simple, high-performance counter-current chromatography method with sequential UV absorbance (254 nm) and evaporative light scattering detection (ELSD) was developed for the quantification of pre-extracted low molecular weight dissolved organic matter (DOM) extracted from natural waters. The method requires solid-phase extraction (SPE) extraction of only small volumes of water samples, here using poly(styrenedivinylbenzene)-based extraction cartridges (Varian PPL). The extracted and concentrated DOM was quantified using reversed-phase high-performance counter-current chromatography (HPCCC), with a water/methanol (5:5) mobile phase and hexane/ethyl acetate (3:7) stationary phase.
View Article and Find Full Text PDFEnviron Sci Process Impacts
September 2015
This review presents an overview of the separation techniques applied to the complex challenge of dissolved organic matter characterisation. The review discusses methods for isolation of dissolved organic matter from natural waters, and the range of separation techniques used to further fractionate this complex material. The review covers both liquid and gas chromatographic techniques, in their various modes, and electrophoretic based approaches.
View Article and Find Full Text PDFNormal-phase high-performance counter-current chromatography (HPCCC) is used to obtain a preliminary fractionation of components in dissolved organic matter (DOM) from a freshwater source. The HPCCC solvent system involved a normal-phase approach with water/methanol (1:1) as the lower stationary phase and hexane/ethyl acetate (1:1) as the upper mobile phase. The critical experiment parameters were optimised: revolution speed 1800 rpm and flow rate 0.
View Article and Find Full Text PDFA simple and rapid method has been developed and validated for the quantitation of vincristine in human plasma by liquid chromatography/tandem mass spectrometry (LC/MS/MS) with atmospheric pressure chemical ionization using on-line solid-phase extraction. The method uses vinblastine as internal standard and the sample preparation is limited just to a plasma protein precipitation step. Further sample clean-up is carried out on-line through a perfusion column preceding an analytical phenyl LC column, the latter directly connected to the mass spectrometer.
View Article and Find Full Text PDF