Background: Although recommended in International Society for Heart and Lung Transplantation (ISHLT) guidelines, transition to mammalian targets of rapamycin (mTOR) inhibitors in heart transplant recipients is not routinely performed, in part due to perceived risk of rejection. This study sought to evaluate the incidence and risk factors for biopsy-proven, clinically relevant rejection following conversion from calcineurin inhibitor (CNI) to sirolimus (SRL) immunosuppression.
Methods: A single center retrospective study was conducted of all consecutive adult patients who underwent orthotopic heart transplantation (OHT) and CNI-free SRL conversion from January 1999 to January 2023.
Eosinophilic myocarditis (EM) is a rare cause of heart failure, with high in-hospital mortality associated with fulminant disease. A 61-year-old female transplant recipient was diagnosed with COVID-19 after presenting with 2 days of constitutional symptoms. She developed acute heart failure from EM.
View Article and Find Full Text PDFBackground: The purpose of this study was to investigate a therapeutic approach targeting the inflammatory response and consequent remodeling from ischemic myocardial injury.
Methods And Results: Coronary thrombus aspirates were collected from patients at the time of ST-segment-elevation myocardial infarction and subjected to array-based proteome analysis. Clinically indistinguishable at myocardial infarction (MI), patients were stratified into vulnerable and resilient on the basis of 1-year left ventricular ejection fraction and death.
Ramp studies are utilized for speed optimization of continuous flow left ventricular assist devices (CF-LVADs). We here report the utility of combined left and right heart catheterization during a ramp study to ensure a comprehensive understanding of the hemodynamic implications on both ventricles. Pressure-volume loop (PV loop) monitoring uncovered compromised systolic and mildly compromised right ventricular function with increasing LVAD speeds, despite improvement in left ventricular unloading.
View Article and Find Full Text PDFThe purpose of this study was to evaluate left ventricular (LV) unloading strategies in patients supported with peripheral venoarterial extracorporeal membrane oxygenation (VA-ECMO). A retrospective review was conducted of all consecutive patients requiring VA-ECMO support for any indication, who underwent novel LV unloading strategies with either direct left atrial venoarterial (LAVA) cannulation or pulmonary artery venoarterial (PAVA) venting, in comparison to Impella and intra-aortic balloon pump (IABP). The primary outcome was successful bridge to transplant, LV assist device, or myocardial recovery.
View Article and Find Full Text PDFBackground: Gastrointestinal bleeding (GIB) in patients with continuous flow left ventricular assist devices (CF-LVADs) is often related to GI angiodysplasia (GIAD). We previously reported data on VEGF inhibition with IV bevacizumab in the treatment of LVAD-associated GIAD bleeding, and now present follow-up data on patients treated with IV bevacizumab and/or low-dose oral pazopanib.
Methods: All consecutive adult patients with LVAD-associated GIB from GIAD treated with bevacizumab or pazopanib, from July 20, 2017 to June 22, 2022, were included in the analysis.
Orthotopic heart transplantation for cardiac sarcoidosis (CS) is becoming increasingly common. Historically, there have been concerns regarding disease recurrence within the allograft. Although rarely reported in the literature, cases of recurrent CS tend to be observed in patients after dose reduction of immunosuppressive therapy and cessation of corticosteroids.
View Article and Find Full Text PDFMechanical circulatory support is increasingly being used as bridge-to-transplant and destination therapy in patients with advanced heart failure. Technologic improvements have led to increased patient survival and quality of life, but infection remains one of the leading adverse events following ventricular assist device (VAD) implantation. Infections can be classified as VAD-specific, VAD-related, and non-VAD infections.
View Article and Find Full Text PDFThe effects of left ventricular unloading on septal function in patients with left ventricular assist devices (LVADs) have not been well characterized in vivo. The purpose of this study was to evaluate the relationship between markers of septal function with echocardiography in relationship to RV dysfunction and late RV failure after LVAD implantation. A retrospective study was conducted of patients supported on centrifugal-flow LVADs implanted over a 10-year period.
View Article and Find Full Text PDFBackground: Timely and accurate discrimination of wide complex tachycardias (WCTs) into ventricular tachycardia (VT) or supraventricular WCT (SWCT) is critically important. Previously we developed and validated an automated VT Prediction Model that provides a VT probability estimate using the paired WCT and baseline 12-lead ECGs. Whether this model improves physicians' diagnostic accuracy has not been evaluated.
View Article and Find Full Text PDF