Inter- and intra-fractional anatomical changes during a radiotherapy treatment can cause differences between the initially planned dose and the delivered dose. The total delivered dose can be accumulated over all fractions by using deformable image registration (DIR). However, there is uncertainty in this process which should be accounted for.
View Article and Find Full Text PDFPlastic scintillation dosimeters (PSDs) are highly suitable for real-time dosimetry on the MR-linac. For optimal performance, the primary signal (scintillation) needs to be separated from secondary optical effects (Cerenkov, fluorescence and optical fiber attenuation). This requires a spectral separation approach and careful calibration.
View Article and Find Full Text PDFBackground And Purpose: MRI-guided online adaptive treatments can account for interfractional variations, however intrafraction motion reduces treatment accuracy. Intrafraction plan adaptation methods, such as the Intrafraction Drift Correction (IDC) or sub-fractionation, are needed. IDC uses real-time automatic monitoring of the tumor position to initiate plan adaptations by repositioning segments.
View Article and Find Full Text PDFBackground And Purpose: Radiotherapy plan verification is generally performed on the reference plan based on the pre-treatment anatomy. However, the introduction of online adaptive treatments demands a new approach, as plans are created daily on different anatomies. The aim of this study was to experimentally validate the accuracy of total doses of multi-fraction plan adaptations in magnetic resonance imaging guided radiotherapy in a phantom study, isolated from the uncertainty of deformable image registration.
View Article and Find Full Text PDFThis work reports on the first seven patients treated with gating and baseline drift correction on the high-field MR-Linac system. Dosimetric analysis showed that the active motion management system improved congruence to the planned dose, efficiently mitigating detrimental effects of intrafraction motion in the upper abdomen.
View Article and Find Full Text PDFBackground And Objectives: Disaster preparedness is an urgent concern, particularly for caregivers of persons with dementia. Developing and executing plans for oneself and another person who needs care can be difficult when the care recipient is cognitively impaired. We sought to better understand caregivers' disaster preparedness for the purpose of generating guidance for future interventions to increase caregiver resilience.
View Article and Find Full Text PDFCOVID-19 regulations have posed challenges for long-term care (LTC). However, few studies have examined how such regulations influenced the care of residents living with dementia. Our objective was to gain an understanding of LTC administrative leaders' perceptions regarding the impact of the COVID-19 response on this population.
View Article and Find Full Text PDFBackground: Lung stereotactic body radiotherapy (SBRT) has proven an effective treatment for medically inoperable lung tumors, even for (ultra-)central tumors. Recently, there has been growing interest in radiation-induced cardiac toxicity in lung radiotherapy. More specifically, dose to cardiac (sub-)structures (CS) was found to correlate with survival after radiotherapy.
View Article and Find Full Text PDFJ Gerontol B Psychol Sci Soc Sci
December 2022
Objectives: The hierarchical mapping technique (HMT) is used to study social convoys, peoples' support systems. Recent research integrating the HMT and the continuing bonds framework suggests that deceased persons may be influential convoy members. Extending this idea, the current study aimed to gain insight regarding how older conjugally bereaved women view the role of a deceased romantic partner in their convoy.
View Article and Find Full Text PDFCentral lung tumours can be treated by magnetic resonance (MR)-guided radiotherapy. Complications might be reduced by decreasing the Planning Target Volume (PTV) using mid-position (midP)-based planning instead of Internal Target Volume (ITV)-based planning. In this study, we aimed to verify a method to automatically derive patient-specific PTV margins for midP-based planning, and show dosimetric robustness of midP-based planning for a 1.
View Article and Find Full Text PDFBackground And Purpose: VMAT is not currently available on MR-linacs but could maximize plan conformality. To mitigate respiration without compromising delivery efficiency, MRI-guided MLC tumour tracking was recently developed for the 1.5 T Unity MR-linac (Elekta AB, Stockholm, Sweden) in combination with IMRT.
View Article and Find Full Text PDFPurpose: To develop and implement an acceptance procedure for the new Elekta Unity 1.5 T MRI-linac.
Methods: Tests were adopted and, where necessary adapted, from AAPM TG106 and TG142, IEC 60976 and NCS 9 and NCS 22 guidelines.
Curative-intent radiotherapy plays an integral role in the treatment of lung cancer and therefore improving its therapeutic index is vital. MR guided radiotherapy (MRgRT) systems are the latest technological advance which may help with achieving this aim. The majority of MRgRT treatments delivered to date have been stereotactic body radiation therapy (SBRT) based and include the treatment of (ultra-) central tumors.
View Article and Find Full Text PDFPurpose: The treatment margins for lung stereotactic body radiotherapy (SBRT) are often large to cover the tumor excursions resulting from respiration, such that underdosage of the tumor can be avoided. Magnetic resonance imaging (MRI)-guided multi-leaf collimator (MLC) tracking can potentially reduce the influence of respiration to allow for smaller treatment margins. However, tracking is accompanied by system latency that may induce residual tracking errors.
View Article and Find Full Text PDFHigh impedance coils (HICs) are suitable as a building block of receive arrays for MRI-guided radiotherapy (MRIgRT) as HICs do not require radiation-attenuating capacitors and dense support materials. Recently, we proved the feasibility of using HICs to create a radiation transparent (i.e.
View Article and Find Full Text PDFThe lack of radiation-attenuating tuning capacitors in high impedance coils (HICs) make HICs an interesting building block of receive arrays for MRI-guided radiotherapy (MRIgRT). Additionally, their flexibility and limited channel coupling allow for low-density support materials, which are likely to be more radiation transparent (radiolucent). In this work, we introduce the use of HICs in receive arrays for MRIgRT treatments.
View Article and Find Full Text PDFBackground And Purpose: The promise of the MR-linac is that one can visualize all anatomical changes during the course of radiotherapy and hence adapt the treatment plan in order to always have the optimal treatment. Yet, there is a trade-off to be made between the time spent for adapting the treatment plan against the dosimetric gain. In this work, the various daily plan adaptation methods will be presented and applied on a variety of tumour sites.
View Article and Find Full Text PDFOnline adaptive radiotherapy using the 1.5 Tesla MR-linac is feasible for SBRT (5 × 7 Gy) of pelvic lymph node oligometastases. The workflow allows full online planning based on daily anatomy.
View Article and Find Full Text PDFThe out-of-field surface dose contribution due to backscattered or ejected electrons, focused by the magnetic field, is evaluated in this work. This electron streaming effect (ESE) can contribute to out-of-field skin doses in orthogonal magnetic resonance guided radiation therapy machines. Using the EGSnrc Monte Carlo package, a phantom is set-up along the central axis of an incident 10 [Formula: see text] 10 cm 7 MV FFF photon beam.
View Article and Find Full Text PDFPurpose: Incidental cardiac exposure during radiation therapy may cause heart disease. Dose-response relationships for cardiac structures (segments) may show which ones are most sensitive to radiation. Radiation-related cardiac injury can take years to develop; thus, studies need to involve women treated using 2-dimensional planning, with segment doses estimated using a typical computed tomography (CT) scan.
View Article and Find Full Text PDFPurpose: The purpose of this study was to evaluate the potential skin dose toxicity contribution of spiralling contaminant electrons (SCE) generated in the air in an MR-linac with a 0.35 or 1.5 T magnetic field using the EGSnrc Monte Carlo (MC) code.
View Article and Find Full Text PDFBackground And Purpose: We aimed to investigate the suitability of treating patients with single brain metastases using stereotactic radiosurgery (SRS) with the MRL and to characterize the dosimetric impact at tissue-air interfaces resulting primarily from the electron return effect (ERE).
Material And Methods: 24 patients treated for intact single brain metastases were analyzed. Three radiotherapy plans with the same prescribed dose were generated for each case: (1) noncoplanar volumetric modulated arc therapy (VMAT), (2) coplanar step-and-shoot intensity modulated radiotherapy (IMRT) on the MRL in the absence (MRLB=0), and (3) in the presence of the transverse magnetic field (MRLB=1.
Purpose: The aim of this study was to determine the relative abilities of compartment models to describe time-courses of F-fluoromisonidazole (FMISO) uptake in tumor voxels of patients with non-small cell lung cancer (NSCLC) imaged using dynamic positron emission tomography. Also to use fits of the best-performing model to investigate changes in fitted rate-constants with distance from the tumor edge.
Methods: Reversible and irreversible two- and three-tissue compartment models were fitted to 24 662 individual voxel time activity curves (TACs) obtained from tumors in nine patients, each imaged twice.
J Appl Clin Med Phys
November 2015
Constancy checks of a well-type ionization chamber should be performed regularly as part of a quality assurance regime. The goal of this work was to test the feasibility of using a linear accelerator and an orthovoltage unit to check the constancy of a well-type chamber's response to an external radiation source. The reproducibility, linearity with dose, variation with dose-rate, and variation between energy-matched units of the well-type chamber response when exposed to 6 MV beams was examined.
View Article and Find Full Text PDFBackground: We present a method for extracting arterial input functions from dynamic [18F]FLT PET images of the head and neck, directly accounting for the partial volume effect. The method uses two blood samples, for which the optimum collection times are assessed.
Methods: Six datasets comprising dynamic PET images, co-registered computed tomography (CT) scans and blood-sampled input functions were collected from four patients with head and neck tumours.