Publications by authors named "Sara Apassiti Esposito"

Introduction: Point of care testing (POCT) represents a valuable option when laboratory data shall be urgently available for timely clinical management, with a turnaround time (TAT) that is unfeasible using conventional laboratory instrumentation. This study was aimed to compare the performance of QBC STAR™ compared to Sysmex XN-module and the reference optical microscopy (OM) assessment.

Material And Methods: One hundred peripheral blood samples, collected in K EDTA tubes, and 50 capillary blood samples obtained by finger stick were analyzed with QBC STAR™, Sysmex XN-module, and OM.

View Article and Find Full Text PDF

Introduction: In the hub and spoke laboratory network, the number of hematology analyzers (HAs) within each core center has increased, and the control of HAs alignment is becoming necessary requirement to ensure analytical quality. In this scenario, HA alignment can be assessed by analyzing the same control material used for internal quality control on multiple HAs, assuming its commutability. The aim of the study was to verify the applicability of a protocol for the alignment of HAs based on control material rather than on fresh whole-blood samples.

View Article and Find Full Text PDF

Background: This study evaluated the clinical significance of cell population data (CPD) parameters obtained on Sysmex XN-9000 in septic patients admitted to intensive care unit (ICU) and stratified according to liver function.

Methods: The study population consisted in 84 patients, 44 of whom did not develop sepsis (NS), whereas the remaining 40 developed sepsis (SE) (n=24) or septic shock (SS) (n=16). Two hundred ostensibly healthy blood donors [healthy subjects (HS)], undergoing routine blood testing before a regular blood donation, were studied.

View Article and Find Full Text PDF

Background: Sepsis is still a major cause of death in intensive care units (ICUs) worldwide. Patients with liver impairment express an imbalanced cytokine response which alters common sepsis biphasic nature. Cytokines measurement is expensive, often unavailable, whereas leukocytes (WBC) evaluation performed through hematology analyzers can provide a practical strategy for monitoring inflammatory response.

View Article and Find Full Text PDF

Background: We evaluated the new body fluid module on Sysmex UF1000-i (UF1000i-BF) for analysis of white blood cell (WBC) and red blood cell (RBC) in cerebrospinal fluid (CSF).

Methods: WBC and RBC counting were compared between UF1000i-BF and Fuchs-Rosenthal counting chamber in 67 CSF samples. This study also included the evaluation of between-day precision, limit of blank (LoB), limit of detection (LoD), functional sensitivity (limit of quantitation, LoQ), carryover and linearity.

View Article and Find Full Text PDF