Threshold testing of cardiac rhythm devices is essential to monitoring the proper functioning of such devices (1). However, the currently method of applying multiple ECG leads to the patient is burdensome and time consuming (2). We are presenting a completely new way to perform cardiac rhythm device threshold testing using pulse oximetry.
View Article and Find Full Text PDFEarly detection of coronary artery disease (CAD) using the acoustic approach, a noninvasive and cost-effective method, would greatly improve the outcome of CAD patients. To detect CAD, we analyze diastolic sounds for possible CAD murmurs. We observed diastolic sounds to exhibit 1/f structure and developed a new method, path length entropy (PLE) and a scaled version (SPLE), to characterize this structure to improve CAD detection.
View Article and Find Full Text PDFCoronary artery disease (CAD) is the leading cause of death in the United States. Although progression of CAD can be controlled using drugs and diet, it is usually detected in advanced stages when invasive treatment is required. Current methods to detect CAD are invasive and/or costly, hence not suitable as a regular screening tool to detect CAD in early stages.
View Article and Find Full Text PDFIndian Pacing Electrophysiol J
July 2010
Indian Pacing Electrophysiol J
May 2010
A 56 year old male with a past medical history of hypertension and dyslipidemia presented with recurrent dizziness. Routine EKG was performed, which suggested frequent junctional extra systoles with compensatory pauses. During telemetry periods of 2:1 block with effective ventricular rate of 34 bpm was observed.
View Article and Find Full Text PDFA 74-year-old male presented to our emergency room with history of sudden onset palpitations associated with syncope. He had a single-chamber implantable cardioverter defibrillator implanted for secondary prevention of sudden cardiac death due to ischaemic cardiomyopathy. Interrogation of the device revealed episodes of non-sustained ventricular tachycardia (NSVT) at 220 ms.
View Article and Find Full Text PDFAtropine is commonly a used pre anesthetic medication. A 22-year-old female with history of unexplained recurrent syncope during electrophysiology developed inducible ventricular arrhythmias when 0.5 mg of atropine was injected intravenously to improve this Wenckebach.
View Article and Find Full Text PDFAims: To compare patients with atrial flutter (AFl) and 1:1 atrioventricular conduction (AVC) with patients with AFl and higher AVC.
Methods: The characteristics of 19 patients with AFl and 1:1 AVC (group A) were compared with those of 116 consecutive patients with AFl and 2:1 AVC or higher degree AV block (group B).
Results: Age, gender, and left ventricular function were similar in the two groups.
Pacing Clin Electrophysiol
November 2007
Introduction: Atrial standstill is a rare heterogeneous arrhythmia characterized by electrical and mechanical standstill and electrical inexcitability. A long-lasting progressive form is seen with cardiac and neuromuscular diseases, and a familial or idiopathic form may have a genetic basis. A transient form was described secondary to drug intoxication, electrolyte imbalance, cardiac inflammation, and ischemia.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
October 2004
Objective: To evaluate left bundle branch block (LBBB) as an indicator of advanced cardiovascular involvement in diabetic (DM) patients by examining left ventricular systolic function and proteinurea.
Methods: Data of 26 diabetic patients with left bundle branch block (DM with LBBB) were compared with data of 31 diabetic patients without left bundle branch block (DM without LBBB) and 18 nondiabetic patients with left bundle branch block (non-DM with LBBB). The inclusion criteria were age >45 years, and diabetes mellitus type 2 of >5 years.