Publications by authors named "Sangyeob Han"

Speckle patterns are a generic feature in coherent imaging techniques like optical coherence tomography (OCT). Although speckles are granular like noise texture, which degrades the image, they carry information that can be benefited by processing and thereby furnishing crucial information of sample structures, which can serve to provide significant important structural details of samples in longitudinal pre-clinical monitoring and assessments. Since the motions of tissue molecules are indicated through speckle patterns, speckle variance OCT (SV-OCT) can be well-utilized for quantitative assessments of speckle variance (SV) in biological tissues.

View Article and Find Full Text PDF

To identify the vascular alteration by photodynamic therapy (PDT), the utilization of high-resolution, high-speed, and wide-field photoacoustic microscopy (PAM) has gained enormous interest. The rapid changes in vasculature during PDT treatment and monitoring of tumor tissue activation in the orthotopic pancreatic cancer model have received limited attention in previous studies. Here, a fully two-axes waterproof galvanometer scanner-based photoacoustic microscopy (WGS-PAM) system was developed for in vivo monitoring of dynamic variations in micro blood vessels due to PDT in an orthotopic pancreatic cancer mouse model.

View Article and Find Full Text PDF
Article Synopsis
  • This study aimed to evaluate surface smoothness and internal bubbles in resin used for treating non-cancerous cervical lesions (NCCLs) using optical coherence tomography (OCT).* -
  • Cross-sectional images of treated NCCLs were analyzed to examine surface quality between dental structures and quantify the amount of resin used, yielding 3D representations of the resin's inner structure.* -
  • The findings highlighted OCT's ability to measure surface quality and detect internal bubbles, making it a valuable tool for both qualitative and quantitative assessments in dental treatment of NCCLs.*
View Article and Find Full Text PDF

Characterizing plant material is crucial in terms of early disease detection, pest control, physiological assessments, and growth monitoring, which are essential parameters to increase production in agriculture and prevent unnecessary economic losses. The conventional methods employed to assess the aforementioned parameters have several limitations, such as invasive inspection, complexity, high time consumption, and costly features. In recent years, optical coherence tomography (OCT), which is an ultra-high resolution, non-invasive, and real-time unique image-based approach has been widely utilized as a significant and potential tool for assessing plant materials in numerous aspects.

View Article and Find Full Text PDF

Sebum is an important component of the skin that has attracted attention in many fields, including dermatology and cosmetics. Pore expansion due to sebum on the skin can lead to various problems. Therefore, it is necessary to analyze the morphological characteristics of sebum.

View Article and Find Full Text PDF

The aim of this study was to develop an optically deviated focusing-based variable depth-of-focus (DOF) oriented optical coherence microscopy (OCM) system to improve the DOF in high-resolution and precise focused imaging. In this study, an approach of varying beam diameter using deviated focusing was employed in the sample arm to enhance the DOF and to confirm precise focusing in OCM imaging. The optically deviated focusing technique was used to vary the focal point and DOF by altering the sample arm beam.

View Article and Find Full Text PDF

Spatial sampling density and data size are important determinants of the imaging speed of photoacoustic microscopy (PAM). Therefore, undersampling methods that reduce the number of scanning points are typically adopted to enhance the imaging speed of PAM by increasing the scanning step size. Since undersampling methods sacrifice spatial sampling density, by considering the number of data points, data size, and the characteristics of PAM that provides three-dimensional (3D) volume data, in this study, we newly reported deep learning-based fully reconstructing the undersampled 3D PAM data.

View Article and Find Full Text PDF

The ischemic stroke animal model evaluates the efficacy of reperfusion and neuroprotective strategies for ischemic injuries. Various conventional methods have been reported to induce the ischemic models; however, controlling specific neurological deficits, mortality rates, and the extent of the infarction is difficult as the size of the affected region is not precisely controlled. In this paper, we report a single laser-based localized target ischemic stroke model development method by simultaneous vessel monitoring and photothrombosis induction using photoacoustic microscopy (PAM), which has minimized the infarct size at precise location with high reproducibility.

View Article and Find Full Text PDF

Whole-directional scanning methodology is required to observe distinctive features of an entire physical structure with a three dimensional (3D) visualization. However, the implementation of whole-directional scanning is challenging for conventional optical coherence tomography (OCT), which scans a limited portion of the sample by utilizing unidirectional and bidirectional scanning methods. Therefore, in this paper an integrated quad-scanner (QS) strategy-based OCT method was implemented to obtain the whole-directional volumetry of a sample by employing four scanning arms installed around the sample.

View Article and Find Full Text PDF

A bacterium in bacterial colony is a basal component of bacterial studies and is therefore of considerable importance. The morphological characteristics of a single colony have been widely used as the standard to identify diverse bacterial species. However, the conventional methods for obtaining morphological information, such as microscopic techniques, cannot provide tomographic views.

View Article and Find Full Text PDF

Depth-visualizing sensitivity can be degraded due to imperfect optical alignment and non-equidistant distribution of optical signals in the pixel array, which requires a measurement of the re-sampling process. To enhance this depth-visualizing sensitivity, reference and sample arm-channeled spectra corresponding to different depths using mirrors were obtained to calibrate the spectrum sampling prior to Fourier transformation. During the process, eight interferogram patterns corresponding to point spread function (PSF) signals at eight optical path length differences were acquired.

View Article and Find Full Text PDF

A large field-of-view and fast scanning of photoacoustic microscopy (PAM) relatively have been difficult to obtain due to the water-drowned structure of the system for the transmission of ultrasonic signals. Researchers have widely studied the achievement of a waterproof scanner for dynamic biological applications with a high-resolution and high signal-to-noise ratio. This Letter reports a novel, to the best of our knowledge, waterproof galvanometer scanner-based PAM system with a successfully attainable ${9.

View Article and Find Full Text PDF

Non-invasive characterization of micro-vibrations in the tympanic membrane (TM) excited by external sound waves is considered as a promising and essential diagnosis in modern otolaryngology. To verify the possibility of measuring and discriminating the vibrating pattern of TM, here we describe a micro-vibration measurement method of latex membrane resembling the TM. The measurements are obtained with an externally generated audio stimuli of 2.

View Article and Find Full Text PDF

Corneal transplantation by full-thickness penetrating keratoplasty with human donor tissue is a widely accepted treatment for damaged or diseased corneas. Although corneal transplantation has a high success rate, a shortage of high-quality donor tissue is a considerable limitation. Therefore, bioengineered corneas could be an effective solution for this limitation, and a decellularized extracellular matrix comprises a promising scaffold for their fabrication.

View Article and Find Full Text PDF

Optical-resolution photoacoustic microscopy (OR-PAM), a promising microscopic imaging technique with high ultrasound resolution and superior optical sensitivity, can provide anatomical, functional, and molecular information at scales ranging from the microvasculature to single red blood cells. In particular, real-time OR-PAM imaging with a high signal-to-noise ratio (SNR) is a prerequisite for widespread use in preclinical and clinical applications. Although several technical approaches have been pursued to simultaneously improve the imaging speed and SNR of OR-PAM, they are bulky, complex, not sensitive, and/or not actually real-time.

View Article and Find Full Text PDF

An application of spectral domain optical coherence tomography (SD-OCT) was demonstrated for a fast industrial inspection of an optical thin film panel. An optical thin film sample similar to a liquid crystal display (LCD) panel was examined. Two identical SD-OCT systems were utilized for parallel scanning of a complete sample in half time.

View Article and Find Full Text PDF