Publications by authors named "Sanggap Lee"

REBa Cu O (REBCO, RE = rare earth)-coated conductor is a competitive option in terms of current-carrying capacity and high-stress durability in developing high-field magnets for nuclear magnetic resonance (NMR) research. Meanwhile, a technical challenge in utilizing a stand-alone REBCO NMR magnet is an unexpected difference in the field uniformity between the designed and measured values after being constructed and charged, i.e.

View Article and Find Full Text PDF

The structural information of small therapeutic compounds complexed in biological matrices is important for drug developments. However, structural studies on ligands bound to such a large and dynamic system as microtubules are still challenging. This article reports an application of the solid-state NMR technique to investigating the bioactive conformation of epothilone B, a microtubule stabilizing agent, whose analog ixabepilone was approved by the U.

View Article and Find Full Text PDF

Nuclear magnetic resonance (NMR) is a fundamental research tool that is widely used in many fields. Despite its powerful applications, unfortunately the low sensitivity of conventional NMR makes it difficult to study thin film or nano-sized samples. In this work, we report the first NMR spectrum obtained from general thin films by using magnetic resonance force microscopy (MRFM).

View Article and Find Full Text PDF

To obtain adsorbents with high capacities for removing heavy metals and organic pollutants capable of quick magnetic separation, we fabricated unique sea-urchin-like magnetic iron oxide (mixed γ-Fe2O3/Fe3O4 phase) nanostructures (called u-MFN) with large surface areas (94.1m(2) g(-1)) and strong magnetic properties (57.9 emu g(-1)) using a simple growth process and investigated their potential applications in water treatment.

View Article and Find Full Text PDF

Solid-state flexible energy storage devices hold the key to realizing portable and flexible electronic devices. Achieving fully flexible energy storage devices requires that all of the essential components (i.e.

View Article and Find Full Text PDF

In-plane to out-of-plane magnetization switching in a single nickel nanorod affixed to an attonewton-sensitivity cantilever was studied at cryogenic temperatures. We observe multiple sharp, simultaneous transitions in cantilever frequency, dissipation, and frequency jitter associated with magnetic switching through distinct intermediate states. These findings suggest a new route for detecting magnetic fields at the nanoscale.

View Article and Find Full Text PDF

We report a unified framework describing all existing protocols for spin manipulation and signal creation in frequency-modulation magnetic resonance force microscopy using classical perturbation theory. The framework is well suited for studying the dependence of the frequency shift on the cantilever amplitude via numerical simulation. We demonstrate the formalism by recovering an exact result for a single spin signal and by simulating, for the first time as a function of cantilever amplitude, the frequency shift due to a volume of noninteracting spins inverted by an adiabatic rapid passage.

View Article and Find Full Text PDF

The measurement of surface charge on nanofibers was achieved by characterizing zeta potential of the nanofibers via a newly developed device for streaming current measurement. Low flow rates were sufficient to generate detectable streaming currents in the absence of an externally applied voltage without damaging nanofiber samples. Zeta potential was calculated by using the Helmholtz-Smoluchowski equation and the measured streaming currents.

View Article and Find Full Text PDF

We have batch-fabricated cantilevers with ∼100 nm diameter nickel nanorod tips and force sensitivities of a few attonewtons at 4.2 K. The magnetic nanorods were engineered to overhang the leading edge of the cantilever, and consequently the cantilevers experience what we believe is the lowest surface noise ever achieved in a scanned probe experiment.

View Article and Find Full Text PDF

We introduce and demonstrate a method of measuring small force gradients acting on a harmonic oscillator in which the force-gradient signal of interest is used to parametrically up-convert a forced oscillation below resonance into an amplitude signal at the oscillator's resonance frequency. The approach, which we demonstrate in a mechanically detected electron spin resonance experiment, allows the force-gradient signal to evade detector frequency noise by converting a slowly modulated frequency signal into an amplitude signal.

View Article and Find Full Text PDF

We report an approach that extends the applicability of ultrasensitive force-gradient detection of magnetic resonance to samples with spin-lattice relaxation times (T (1)) as short as a single cantilever period. To demonstrate the generality of the approach, which relies on detecting either cantilever frequency or phase, we used it to detect electron spin resonance from a T (1) = 1 ms nitroxide spin probe in a thin film at 4.2 K and 0.

View Article and Find Full Text PDF