Publications by authors named "Sang Wan Shin"

Purpose: The aim of this systematic review was to compare treatment outcomes in terms of implant survival rate, marginal bone loss, and patient-reported outcome measures (PROMs) between narrow-diameter implants and regular-diameter implants (RDIs) for mandibular implant overdentures (MIOs).

Methods: This study was based on the methodology adapted as per Cochrane. Medline, Embase, the Cochrane Central Register of Controlled Trials, Web of Science, and Scopus were searched for pertinent studies published by July 22, 2022.

View Article and Find Full Text PDF

Objectives: This retrospective study to evaluate the treatment outcomes of mandibular mini-implant overdentures (MIODs) placed under a two-step immediate loading protocol.

Background: The mini-implant overdenture emphasises the advantages of simplicity using flapless surgery and immediate loading. However, some mini-implant have lowe initial stability.

View Article and Find Full Text PDF

Purpose: The aim of this study was to investigate and compare the color stability of provisional restorative materials fabricated by 3D printing, dental milling, and conventional materials.

Materials And Methods: For the experimental groups, two commercially available 3D-printing provisional resins (E-Dent 100; EnvisionTEC GmbH, Germany & VeroGlaze™; Stratasys®, USA), two dental milling blocks (PMMA Disk; Yamahachi Dental Co., Japan & Telio®CAD; Ivoclar Vivadent AG, Liechtenstein), and two conventional materials (Alike™; GC Co.

View Article and Find Full Text PDF

This study aimed to compare bone healing and implant stability for three types of dental implants: a threaded implant, a three-dimensional (3D)-printed implant without spikes, and a 3D-printed implant with spikes. In four beagle dogs, left and right mandibular premolars (2nd, 3rd, and 4th) and 1st molars were removed. Twelve weeks later, three types of titanium implants (threaded implant, 3D-printed implant without spikes, and 3D-printed implant with spikes) were randomly inserted into the edentulous ridges of each dog.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST).

Materials And Methods: Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck).

View Article and Find Full Text PDF

Purpose: The purpose of this study is to evaluate the effects of type of magnet attachment and implant angulation in two implant overdenture models.

Materials And Methods: Magnet attachments used in this study were flat and dome types (MGT5515, MGT5520D, Dentium Co., Seoul, Korea).

View Article and Find Full Text PDF

Dental panoramic radiographs (DPRs) provide information required to potentially evaluate bone density changes through a textural and morphological feature analysis on a mandible. This study aims to evaluate the discriminating performance of deep convolutional neural networks (CNNs), employed with various transfer learning strategies, on the classification of specific features of osteoporosis in DPRs. For objective labeling, we collected a dataset containing 680 images from different patients who underwent both skeletal bone mineral density and digital panoramic radiographic examinations at the Korea University Ansan Hospital between 2009 and 2018.

View Article and Find Full Text PDF

Objective: This review evaluated the change in treatment outcomes after conversion from conventional removable partial denture (RPD) to implant-assisted removable partial denture (IARPD). The patient-reported outcome measures (PROMs), objective parameters for evaluation of functional performance, and biological and mechanical complication were evaluated.

Materials And Methods: This systematic review was based on the Cochrane review methodology and followed the criteria of the preferred reporting items for systematic reviews and meta-analyses (PRISMA).

View Article and Find Full Text PDF

Objectives: To compare the clinical treatment outcomes of maxillary four-implant retained overdentures with either splinted (bar) attachments or non-splinted (ball) attachments.

Material And Methods: Forty participants who were dissatisfied with their existing conventional maxillary complete dentures were included in this randomized controlled trial. Six months after implant placement, a definitive prosthesis was inserted.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to compare mechanical and physical properties of injection-molded thermoplastic denture base resins.

Materials And Methods: In this study, six commercially available products (VA; Valplast, LC; Lucitone, ST; Smiltone, ES; Estheshot-Bright, AC; Acrytone, WE; Weldenz) were selected from four types of thermoplastic denture base materials (Polyamide, Polyester, Acrylic resin and Polypropylene). The flexural properties and shore D hardness have been investigated and water sorption and solubility, and color stability have evaluated.

View Article and Find Full Text PDF

Purpose: This study aimed to assess the effect of non-thermal plasma on the shear bond strength of resin cements to polyetherketoneketone (PEKK) in comparison to other surface treatment methods.

Materials And Methods: Eighty PEKK discs were subjected to different surface treatments: (1) Untreated (UT); (2) Non-thermal plasma (NTP); (3) Sandblasting with 50 µm AlO particles (SB); and (4) Sandblasting + Non-thermal plasma (SB+NTP). After each surface treatment, the contact angle was measured.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate treatment outcomes of mandibular overdentures retained by two different mini-implant systems with ball attachments under a two-step immediate loading protocol.

Materials And Methods: This clinical trial investigated treatment outcomes of mandibular mini-implant overdentures in 45 edentulous patients. MDI implants (3M ESPE) and SlimLine implants (Dentium) were randomly selected for placement in the anterior mandible in each group (MDI = 21; SlimLine = 24) with a flapless surgical approach.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the effectiveness of growth factor-loaded collagen membranes for promoting new bone growth in horizontal bone augmentation.
  • Six male beagle dogs had mandibular defects surgically created, then treated with one of three membrane types for comparison.
  • Results showed that while the rhBMP-2 loaded membrane led to greater bone formation at 8 weeks, by 16 weeks, there were no significant differences in new bone growth or horizontal bone gain among the three membrane types.
View Article and Find Full Text PDF

Purpose: To evaluate the clinical efficacy of five commercially available desensitizing agents with different mechanisms applied to hypersensitive teeth.

Methods: A randomized clinical trial was conducted on subjects suffering dentin hypersensitivity in Korea University Guro Hospital from October 2013 to April 2015. A total of 64 subjects met the selection criteria and were randomly assigned to five commercially available desensitizing agents, and applied according to the manufacturers' instructions.

View Article and Find Full Text PDF

Purpose: The object of the present study was to evaluate the shear bonding strength of composite to PEKK by applying several methods of surface treatment associated with various bonding materials.

Materials And Methods: One hundred and fifty PEKK specimens were assigned randomly to fifteen groups (n = 10) with the combination of three different surface treatments (95% sulfuric acid etching, airborne abrasion with 50 µm alumina, and airborne abrasion with 110 µm silica-coating alumina) and five different bonding materials (Luxatemp Glaze & Bond, Visio.link, All-Bond Universal, Single Bond Universal, and Monobond Plus with Heliobond).

View Article and Find Full Text PDF
Article Synopsis
  • The study aims to analyze and compare polyetherketoneketone (PEKK) with zirconia and titanium for implant-supported prostheses using 3D finite element analysis based on cone beam computed tomography and CAD data.
  • A geometric model featuring four maxillary implants and a prosthesis framework was created to simulate different materials' properties in a controlled environment.
  • The findings indicate that while the PEKK framework reduces stress on implants under compression, it can increase stress under tension, suggesting that more rigid materials provide better overall stress distribution and safety for the prosthesis components.
View Article and Find Full Text PDF

Purpose: The objective of this study was to determine the cumulative survival rate (CSR) and associated risk factors of Implantium implants by retrospective clinical study.

Materials And Methods: Patients who received Implantium implants (Dentium Co., Seoul, Korea) at Korea University Guro Hospital from 2004 to 2011 were included.

View Article and Find Full Text PDF

Purpose: To examine the disparity of single-crown implant failure with a similar loss of the splinted prosthesis in differing anatomical locations while controlling for other demographic and clinical variables that may confound the relationship between prosthesis types and implant loss.

Materials And Methods: A multicenter retrospective cohort study was designed to include patients treated with dental implants from 2003 to 2014. The variables included age, sex, systemic disease, bone graft, implant placement date, position of dental implant, length of dental implant, diameter of dental implant, loading time, type of prosthesis, type of opposing occlusion, latest check date, and survival or loss of the dental implant.

View Article and Find Full Text PDF

Digital impressions can be a useful option that reduces patient discomfort and simplifies clinical procedures such as accurate impression recordings. In this report, a patient with a partial maxillectomy was managed with a metal frame fabricated from a digital impression through an intraoral scanner. The final impression employed the altered cast technique for the fabrication of the obturator.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluated the biomechanical behavior and safety of PEKK, a high-performance polymer, as a dental post-core material using finite element analysis (FEA) in comparison to traditional materials like gold and fiberglass.
  • A 3D model of a maxillary central incisor was created, and a cyclic loading force of 50 N was applied at a 45° angle to assess the material properties.
  • While PEKK demonstrated favorable stress distribution and high resistance to failure, it was found to have a greater risk of debonding and crown failure over time compared to metal or fiberglass post-core systems.
View Article and Find Full Text PDF

Purpose: This systematic review evaluated treatment outcomes for mandibular mini-implant-retained overdentures (MMIOs) in terms of (1) implant survival rate, (2) peri-implant marginal bone loss, (3) prosthodontic maintenance and complication occurrence, and (4) patient satisfaction.

Materials And Methods: Pertinent literature published in English before October 12, 2015 was identified using a MEDLINE and EMBASE search strategy and hand searching of relevant journals. Inclusion and exclusion criteria were applied to the titles and abstracts and subsequently to the full text of included studies.

View Article and Find Full Text PDF

The most common complication of implant ball attachments is loss of retention via structural wear. Hence, parallel placement of implants was identified as a prerequisite for long-term success. In this case, although severe angulation was formed between implants due to severe alveolar bone resorption, parallel ball attachments on the implants could be fabricated using computer-aided design/computer-assisted manufacture.

View Article and Find Full Text PDF

Purpose: To investigate the effect of implant diameter on fatigue strength using static and cyclic load test.

Materials And Methods: Four different implant systems-SuperLine (Φ4.0), NRLine (Φ3.

View Article and Find Full Text PDF