An oral sorbent with high capacity for NH is desirable in lowering the blood urea level and mitigating the dialysis burden for end-stage kidney disease (ESKD) patients. Zirconium phosphate (ZrP) is an amorphous cation ion exchanger with high NH binding capacity as a sorbent material, but its selectivity to remove NH is limited in the presence of other competing ions in water solution. We previously have developed a gas-permeable and hydrophobic perfluorocarbon coating on ZrP, which improves ZrP's NH selectivity.
View Article and Find Full Text PDFVascular graft thrombosis is a long-standing clinical problem. A myriad of efforts have been devoted to reducing thrombus formation following bypass surgery. Researchers have primarily taken a chemical approach to engineer and modify surfaces, seeking to make them more suitable for blood contacting applications.
View Article and Find Full Text PDFThe healing of critical-sized bone defects is a major challenge in the field of bone tissue engineering. Gelatin-related hydrogels have emerged as a potential solution due to their desirable properties. However, their limited osteogenic, mechanical, and reactive oxygen species (ROS)-scavenging capabilities have hindered their clinical application.
View Article and Find Full Text PDFShape-memory materials hold great potential to impart medical devices with functionalities useful during implantation, locomotion, drug delivery, and removal. However, their clinical translation is limited by a lack of non-invasive and precise methods to trigger and control the shape recovery, especially for devices implanted in deep tissues. In this study, the application of image-guided high-intensity focused ultrasound (HIFU) heating is tested.
View Article and Find Full Text PDFDeveloping an ambulatory assist lung (AAL) for patients who need continuous extracorporeal membrane oxygenation has been associated with several design objectives, including the design of compact components, optimization of gas transfer efficiency, and reduced thrombogenicity. In an effort to address thrombogenicity concerns with currently utilized component biomaterials, a low molecular weight water soluble siloxane-functionalized zwitterionic sulfobetaine (SB-Si) block copolymer was coated on a full-scale AAL device set via a one pot aqueous circulation coating. All device parts including hollow fiber bundle, housing, tubing and cannular were successfully coated with increasing atomic compositions of the SB block copolymer and the coated surfaces showed a significant reduction of platelet deposition while gas exchange performance was sustained.
View Article and Find Full Text PDFAn oral sorbent to remove NH within the small intestine of end-stage kidney disease (ESKD) patients could reduce blood urea levels and diminish their dialysis treatment burden. But current sorbent materials like amorphous zirconium phosphate particles Zr(HPO)·HO (ZrP) lack the selectivity to remove NH in water solution with other competing ions. Our previous work found that a gas-permeable, hydrophobic polydimethylsiloxane (PDMS) coating on ZrP improved the material's selectivity for NH.
View Article and Find Full Text PDFAtherosclerosis is a common cause of coronary artery disease and a significant factor in broader cardiovascular diseases, the leading cause of death. While implantation of a stent is a prevalent treatment of coronary artery disease, a frequent complication is restenosis, where the stented artery narrows and stiffens. Although early detection of restenosis can be achieved by continuous monitoring, no available device offers such capability without surgeries.
View Article and Find Full Text PDFFetal aqueductal stenosis (AS) is one of the most common causes of congenital hydrocephalus, which increases intracranial pressure due to partial or complete obstruction of cerebrospinal fluid (CSF) flow within the ventricular system. Approximately 2-4 infants per 10,000 births develop AS, which leads to progressive hydrocephalus, which enlarges the head often necessitating delivery by cesarean section. Most babies born with AS are severely neurologically impaired and experience a lifetime of disability.
View Article and Find Full Text PDFA sorbent with a high enough capacity for NH could serve as an oral binder to lower urea levels in end-stage kidney disease (ESKD) patients. A hydrogen-loaded cation exchanger such as zirconium phosphate Zr(HPO)·HO (ZrP) is a promising candidate for this application. However, the NH binding selectivity versus other ions must be improved.
View Article and Find Full Text PDFPoly(dimethylsiloxane) (PDMS) has been used in a wide range of biomedical devices and medical research due to its biostability, cytocompatibility, gas permeability, and optical properties. Yet, some properties of PDMS create critical limitations, particularly fouling through protein and cell adhesion. In this study, a diallyl-terminated sulfobetaine (SB-diallyl) molecule was synthesized and then directly mixed with a commercial PDMS base (Sylgard 184) and curing agent to produce a zwitterionic group-bearing PDMS (PDMS-SB) hybrid that does not require a complex or an additional surface modification process for the desired end product.
View Article and Find Full Text PDFBackground: A wearable artificial lung could improve lung transplantation outcomes by easing implementation of physical rehabilitation during long-term pretransplant respiratory support. The Modular Extracorporeal Lung Assist System (ModELAS) is a compact pumping artificial lung currently under development. This study evaluated the long-term in vivo performance of the ModELAS during venovenous support in awake sheep.
View Article and Find Full Text PDFBackground: Non-invasive and lung-protective ventilation techniques may improve outcomes for patients with an acute exacerbation of chronic obstructive pulmonary disease or moderate acute respiratory distress syndrome by reducing airway pressures. These less invasive techniques can fail due to hypercapnia and require transitioning patients to invasive mechanical ventilation. Extracorporeal CO removal devices remove CO independent of the lungs thereby controlling the hypercapnia and permitting non-invasive or lung-protective ventilation techniques.
View Article and Find Full Text PDFPolydimethylsiloxane (PDMS) is commonly used in medical devices because it is non-toxic and stable against oxidative stress. Relatively high blood platelet adhesion and the need for chemical crosslinking through curing, however, limit its utility. In this research, a biostable PDMS-based polyurethane-urea bearing zwitterion sulfobetaine (PDMS-SB-UU) was synthesized for potential use in the fabrication or coating of blood-contacting devices, such as a conduits, artificial lungs, and microfluidic devices.
View Article and Find Full Text PDFAfter more than 22 years of research challenges and innovation, the heart valve tissue engineering paradigm still attracts attention as an approach to overcome limitations which exist with clinically utilized mechanical or bioprosthetic heart valves. Despite encouraging results, delayed translation can be attributed to limited knowledge on the concurrent mechanisms of biomaterial degradation in vivo, host inflammatory response, cell recruitment, and de novo tissue elaboration. This study aimed to reduce this gap by evaluating three alternative levels at which lability could be incorporated into candidate polyurethane materials electroprocessed into a valve scaffold.
View Article and Find Full Text PDFThe inner surfaces of arteries and veins are naturally anti-thrombogenic, whereas synthetic materials placed in blood contact commonly experience thrombotic deposition that can lead to device failure or clinical complications. Presented here is a bioinspired strategy for self-cleaning anti-thrombotic surfaces using actuating surface topography. As a first test, wrinkled polydimethylsiloxane planar surfaces are constructed that can repeatedly transition between smooth and wrinkled states.
View Article and Find Full Text PDFPolymeric coatings can provide temporary stability to bioresorbable metallic stents at the initial stage of deployment by alleviating rapid degradation and providing better interaction with surrounding vasculature. To understand this interfacing biocompatibility, this study explored the endothelial-cytocompatibility of polymer-coated magnesium (Mg) alloys under static and dynamic conditions compared to that of non-coated Mg alloy surfaces. Poly (carbonate urethane) urea (PCUU) and poly (lactic-co-glycolic acid) (PLGA) were coated on Mg alloys (WE43, AZ31, ZWEKL, ZWEKC) and 316L stainless steel (316L SS, control sample), which were embedded into a microfluidic device to simulate a vascular environment with dynamic flow.
View Article and Find Full Text PDFDegradable metallic stents, most commonly composed of Mg-based alloys, are of interest as an alternative to traditional metallic stents for application in cardiac and peripheral vasculature. Two major design challenges with such stents are control of the corrosion rate and acute presentation of a nonthrombogenic surface to passing blood. In this study, several types of sulfobetaine (SB)-bearing biodegradable polyurethanes were developed and assessed as physical, chemical, and combination-type coatings for a model degradable Mg alloy, AZ31.
View Article and Find Full Text PDFRandom weakening of an intracranial blood vessel results in abnormal blood flow into an aneurysmal sac. Recent advancements show that an implantable flow diverter, integrated with a medical stent, enables a highly effective treatment of cerebral aneurysms by guiding blood flow into the normal vessel path. None of such treatment systems, however, offers post-treatment monitoring to assess the progress of sac occlusion.
View Article and Find Full Text PDFNatural surfaces excel in self-renewal and preventing bio-fouling, while synthetic materials placed in contact with complex fluids quickly foul [1, 3]. We present a novel biophysics inspired mechanism [4, 5] for surface renewal using actuating surface topography, generated by wrinkling. We calculate a critical surface curvature, given by an intrinsic characteristic length scale of the fouling layer that accounts for its effective flexural or bending stiffness and adhesion energy, beyond which surface renewal occurs.
View Article and Find Full Text PDFThe challenge of developing scaffolds to reconstruct critical-sized calvarial defects without the addition of high levels of exogenous growth factor remains relevant. Both osteogenic regenerative efficacy and suitable mechanical properties for the temporary scaffold system are of importance. In this study, a Mg alloy mesh reinforced polymer/demineralized bone matrix (DBM) hybrid scaffold was designed where the hybrid scaffold was fabricated by a concurrent electrospinning/electrospraying of poly(lactic-co-glycolic acid) (PLGA) polymer and DBM suspended in hyaluronic acid (HA).
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
October 2018
Respiratory assist devices, that utilize ∼2 m of hollow fiber membranes (HFMs) to achieve desired gas transfer rates, have been limited in their adoption due to such blood biocompatibility limitations. This study reports two techniques for the functionalization and subsequent conjugation of zwitterionic sulfobetaine (SB) block copolymers to polymethylpentene (PMP) HFM surfaces with the intention of reducing thrombus formation in respiratory assist devices. Amine or hydroxyl functionalization of PMP HFMs (PMP-A or PMP-H) was accomplished using plasma-enhanced chemical vapor deposition.
View Article and Find Full Text PDFRecent studies show improved outcomes in ambulated lung failure patients. Ambulation still remains a challenge in these patients. This necessitates development of more compact and less cumbersome respiratory support specifically designed to be wearable.
View Article and Find Full Text PDFSurface coimmobilization modifications of blood-contacting devices with both antithrombogenic moieties and endothelium-inducing biomolecules may create a synergistic effect to improve their performance. However, it is difficult to perform covalent dual-functionalization with both biomolecules on the surface of normally used synthetic polymeric substrates. Herein, we developed and characterized an orthogonally functionalizable polymer, biodegradable elastic poly(ester urethane)urea with disulfide and amino groups (PUSN), which was further fabricated into electropun fibrous scaffolds and surface modified with heparin and endothelial progenitor cells (EPC) recruiting peptide (TPS).
View Article and Find Full Text PDFColloids Surf B Biointerfaces
August 2016
Vascular stent design continues to evolve to further improve the efficacy and minimize the risks associated with these devices. Drug-eluting coatings have been widely adopted and, more recently, biodegradable stents have been the focus of extensive evaluation. In this report, biodegradable elastomeric polyurethanes were synthesized and applied as drug-eluting coatings for a relatively new class of degradable vascular stents based on Mg.
View Article and Find Full Text PDFAlthough the thiol click reaction is an attractive tool for postpolymerization modification of thiolmers, thiol groups are easily oxidized, limiting the potential for covalent immobilization of bioactive molecules. In this study, a series of biodegradable polyurethane elastomers incorporating stable cyclic disulfide groups was developed and characterized. These poly(ester urethane)urea (PEUU-SS) polymers were based on polycaprolactone diol (PCL), oxidized dl-dithiothreitol (O-DTT), lysine diisocyanate (LDI), or butyl diisocyanate (BDI), with chain extension by putrescine.
View Article and Find Full Text PDF