Purpose: The proximity or overlap of planning target volume (PTV) and organs-at-risk (OARs) poses a major challenge in stereotactic body radiation therapy (SBRT) of pancreatic cancer (PACA). This international treatment planning benchmark study investigates whether simultaneous integrated boost (SIB) and simultaneous integrated protection (SIP) concepts in PACA SBRT can lead to improved and harmonized plan quality.
Methods And Materials: A multiparametric specification of desired target doses (gross target volume [GTV], GTV, PTV, and PTV) with 2 prescription doses of GTV = 5 × 9.
Background And Purpose: As no guidelines for pencil beam scanning (PBS) proton therapy (PT) of paediatric posterior fossa (PF) tumours exist to date, this study investigated planning techniques across European PT centres, with special considerations for brainstem and spinal cord sparing.
Materials And Methods: A survey and a treatment planning comparison were initiated across nineteen European PBS-PT centres treating paediatric patients. The survey assessed all aspects of the treatment chain, including but not limited to delineations, dose constraints and treatment planning.
Purpose: To investigate the current practice patterns in image-guided particle therapy (IGPT) for cranio-spinal irradiation (CSI).
Methods: A multi-institutional survey was distributed to European particle therapy centres to analyse all aspects of IGPT. Based on the survey results, a Delphi consensus analysis was developed to define minimum requirements and optimal workflow for clinical practice.
Background: To introduce and compare multiple biological effectiveness guided (BG) proton plan optimization strategies minimizing variable relative biological effectiveness (RBE) induced dose burden in organs at risk (OAR) while maintaining plan quality with a constant RBE.
Methods: Dose-optimized (DOSEopt) proton pencil beam scanning reference treatment plans were generated for ten cranial patients with prescription doses ≥ 54 Gy(RBE) and ≥ 1 OAR close to the clinical target volume (CTV). For each patient, four additional BG plans were created.
Purpose: To examine the dosimetric feasibility of hypofractionated/dose escalated radiation therapy in patients with localized prostate carcinoma using simultaneous integrated boost intensity-modulated proton beam therapy (SIB-IMPT) in absence or presence of prostate-rectum spacer.
Methods: IMPT technique was implemented in 23 patients with intermediate- and high-risk prostate cancer treated at West German Proton Therapy Centre from March 2016 till June 2018, using SIB technique prescribing 60 GyRBE and 72 GyRBE in 30 fractions to PTV1 (prostate and seminal vesicle) and PTV2 boost (prostate and proximal seminal vesicle), respectively. In 15 patients, a transperineal injection of hydrogel was applied prior to radiotherapy to increase the distance between prostate and rectum.
Proton therapy makes use of the favorable depth-dose distribution with its characteristic Bragg peak to spare normal tissue distal of the target volume. A steep dose gradient would be desired in lateral dimensions, too. The widespread spot scanning delivery technique is based, however, on pencil-beams with in-air spot full-widths-at-half-maximum of typically 1 cm or more.
View Article and Find Full Text PDFProton fields delivered by the active scanning technique can be interfered with the intrafractional motion. This in-silico study seeks to mitigate the dosimetric impacts of motion artifacts, especially its interplay with the time-modulated dose delivery. Here four-dimensional (4d) robust optimization and dose repainting, which is the multiple application of the same field with reduced fluence, were combined.
View Article and Find Full Text PDFPencil beam scanning (PBS) proton therapy enables better dose conformality for complex anatomical geometries than passive proton scattering techniques, but is more susceptible to organ motion. This becomes an issue when treating moving tumours in the thorax or abdomen. Novel four-dimensional treatment planning approaches have been developed to increase the robustness of PBS plans against motion.
View Article and Find Full Text PDF