The aim of this work is to present a reproducible methodology for the evaluation of total equivalent doses in organs during proton therapy facilities. The methodology is based on measuring the dose equivalent in representative locations inside an anthropomorphic phantom where photon and neutron dosimeters were inserted. The Monte Carlo simulation was needed for obtaining neutron energy distribution inside the phantom.
View Article and Find Full Text PDFPurpose: To perform a systematic and thorough assessment, using the Uncomplicated and Cancer-Free Control Probability (UCFCP) function, of a broad range of photon prostate cancer RT treatments, on the same scenario (a unique pelvic CT set). UCFCP considers, together with the probabilities of local tumour control (TCP) and deterministic (late) sequelae (NTCP), the second primary cancer risk (SPCR) due to photon and neutron peripheral doses.
Methods And Materials: Thirty-six radiotherapy plans were produced for the same CT.
There is a growing interest in the combined use of Stereotactic Body Radiation Therapy (SBRT) with Flattening Filter Free (FFF) due to the high local control rates and reduced treatment times, compared to conventionally fractionated treatments. It has been suggested that they may also provide a better radiation protection to radiotherapy patients as a consequence of the expected decrease in peripheral doses. This work aims to determine this reduction in unattended out-of-field regions, where no CT information is available but an important percentage of second primary cancers occur.
View Article and Find Full Text PDFThe aim of this work was to estimate peripheral neutron and photon doses associated with the conventional 3D conformal radiotherapy techniques in comparison to modern ones such as Intensity modulated radiation therapy and volumetric modulated arc therapy. Assessment in terms of second cancer incidence ought to peripheral doses was also considered. For that, a dosimetric methodology proposed by the authors has been applied beyond the region where there is no CT information and, thus, treatment planning systems do not calculate and where, nonetheless, about one third of second primary cancers occurs.
View Article and Find Full Text PDFPurpose: Biological treatment plan evaluation does not currently consider second cancer induction from peripheral doses associated to photon radiotherapy. The aim is to propose a methodology to characterize the therapeutic window by means of an integral radiobiological approach, which considers not only Tumour Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) but also Secondary Cancer Probability (SCP).
Methods: Uncomplicated and Cancer-Free Control Probability (UCFCP) function has been proposed assuming a statistically uncorrelated response for tumour and normal tissues.
Purpose: Neutron peripheral contamination in high-energy radiotherapy implies an increase of secondary radiation-induced cancer risk. Although peripheral neutron dose (PND) has been evaluated in organs, few studies have been performed regarding patient size. This work aims to improve an existing methodology for adult patient PND estimations to generalize it to young and children, for its implementation in treatment planning systems (TPS).
View Article and Find Full Text PDFOne of the major causes of secondary malignancies after radiotherapy treatments are peripheral doses, known to increase for some newer techniques (such as IMRT or VMAT). For accelerators operating above 10MV, neutrons can represent important contribution to peripheral doses. This neutron contamination can be measured using different passive or active techniques, available in the literature.
View Article and Find Full Text PDFThe increasing interest of the medical community to radioinduced second malignancies due to photoneutrons in patients undergoing high-energy radiotherapy, has stimulated in recent years the study of peripheral doses, including the development of some dedicated active detectors. Although these devices are designed to respond to neutrons only, their parasitic photon response is usually not identically zero and anisotropic. The impact of these facts on measurement accuracy can be important, especially in points close to the photon field-edge.
View Article and Find Full Text PDFPurpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter "immeasurable" by definition.
View Article and Find Full Text PDFActive thermal neutron detectors are used in a wide range of measuring devices in medicine, industry and research. For many applications, the long-term stability of these devices is crucial, so that very well controlled neutron fields are needed to perform calibrations and repeatability tests. A way to achieve such reference neutron fields, relying on a 3 MV Tandem Pelletron accelerator available at the CNA (Seville, Spain), is reported here.
View Article and Find Full Text PDFPurpose: Knowing the contribution of neutron to collateral effects in treatments is both a complex and a mandatory task. This work aims to present an operative procedure for neutron estimates in any facility using a neutron digital detector.
Methods: The authors' previous work established a linear relationship between the total second cancer risk due to neutrons (TR(n)) and the number of MU of the treatment.
Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom.
View Article and Find Full Text PDFPurpose: Second cancer, as a consequence of a curative intent radiotherapy (RT), represents a growing concern nowadays. The unwanted neutron exposure is an important contributor to this risk in patients irradiated with high energy photon beams. The design and development by our group of a neutron digital detector, together with the methodology to estimate, from the detector readings, the neutron equivalent dose in organs, made possible the unprecedented clinical implementation of an online and systematic neutron dosimetry system.
View Article and Find Full Text PDFNeutron peripheral contamination in patients undergoing high-energy photon radiotherapy is considered as a risk factor for secondary cancer induction. Organ-specific neutron-equivalent dose estimation is therefore essential for a reasonable assessment of these associated risks. This work aimed to develop a method to estimate neutron-equivalent doses in multiple organs of radiotherapy patients.
View Article and Find Full Text PDFPurpose: Concerns about the secondary cancer risks associated to the peripheral neutron and photon contamination in photon modern radiotherapy (RT) techniques (e.g., Intensity Modulated RT -IMRT- or Intensity Modulated Arc Therapy -IMAT) have been widely raised.
View Article and Find Full Text PDFPurpose: The delivery of the therapeutic radiation dose to the tumour in photon radiotherapy, also implies dose deposition in distant organs (peripheral dose) related to secondary cancers induction (Hall and Wuu, Int J Radiat Oncol Biol Phys 56:83-88, 2003). Therefore, peripheral dose estimation in MU-demanding techniques, such as Helical TomoTherapy (HT), becomes relevant. TLD measurements and Monte Carlo modelling were compared by D'Agostino (Strahlenther Onkol 187:693, 2011).
View Article and Find Full Text PDFModern dosimetry protocols are based on the use of ionization chambers provided with a calibration factor in terms of absorbed dose to water. The basic formula to determine the absorbed dose at a user's beam contains the well-known beam quality correction factor that is required whenever the quality of radiation used at calibration differs from that of the user's radiation. The dosimetry protocols describe the whole ionization chamber calibration procedure and include tabulated beam quality correction factors which refer to 60Co gamma radiation used as calibration quality.
View Article and Find Full Text PDFSignificant deviations from the expected dose have been reported in the absolute dosimetry validation of an intensity modulated radiation therapy treatment when individual segments are analyzed. However, when full treatment is considered and all segment doses are added together, these discrepancies fade out, leading to overall dose deviations below a 5% action level. This contradictory behavior may be caused by a partial compensation between detector over-responding and under-responding for measurement conditions far from radiation equilibrium.
View Article and Find Full Text PDFA new method for the measurement of output factors of narrow beams is presented in this work. By combining a new large area parallel plane ionization chamber (PTW model T34070) with a relative film dosimetry the output factors of small square fields of a 6 MV beam shaped by a MLC were measured. Several detectors (three ionization chambers, two solid state detectors and film) and Monte Carlo simulation were also employed to validate this new methodology and also to determine those detectors more suitable for narrow beam output factor determination.
View Article and Find Full Text PDFPurpose: Intensity-modulated radiotherapy (IMRT) represents an important method for improving RT. The IMRT relative dosimetry checks are well established; however, open questions remain in reference dosimetry with ionization chambers (ICs). The main problem is the departure of the measurement conditions from the reference ones; thus, additional uncertainty is introduced into the dose determination.
View Article and Find Full Text PDFIn order to obtain realistic and reliable Monte Carlo simulations of medical linac photon beams, an accurate determination of the parameters that define the primary electron beam that hits the target is a fundamental step. In this work we propose a new methodology to commission photon beams in Monte Carlo simulations that ensures the reproducibility of a wide range of clinically useful fields. For such purpose accelerated Monte Carlo simulations of 2 x 2, 10 x 10, and 20 x 20 cm2 fields at SSD = 100 cm are carried out for several combinations of the primary electron beam mean energy and radial FWHM.
View Article and Find Full Text PDFA liquid isooctane (C8H18) filled ionization chamber linear array developed for radiotherapy quality assurance, consisting of 128 pixels (each of them with a 1.7 mm pitch), has been used to acquire profiles of several intensity modulated fields. The results were compared with film measurements using the gamma test.
View Article and Find Full Text PDFReference dosimetry of photon fields is a well-established subject and currently available protocols (such as the IAEA TRS-398 and AAPM TG-51) provide methods for converting the ionization chamber (IC) reading into dose to water, provided reference conditions of charged particle equilibrium (CPE) are fulfilled. But these protocols cannot deal with the build-up region, where the lack of CPE limits the applicability of the cavity theorems and so the chamber correction factors become depth dependent. By explicitly including the IC geometry in the Monte Carlo simulations, depth-dependent dose correction factors are calculated for a PTW 30001 0.
View Article and Find Full Text PDFBackground And Purpose: Absolute dose measurements for Intensity Modulated Radiotherapy (IMRT) beamlets is difficult due to the lack of lateral electron equilibrium. Recently we found that the absolute dosimetry in the penumbra region of the IMRT beamlet, can suffer from significant errors (Capote et al., Med Phys 31 (2004) 2416-2422).
View Article and Find Full Text PDF