The gluteus medius allows hip abduction and stabilization of the pelvis when walking. A rupture of the gluteus medius tendon is associated with lateral hip pain, weakness, a positive Trendelenburg sign, and a limp. Diagnosis is confirmed by ultrasound or MRI.
View Article and Find Full Text PDF: T1 relaxation time has been shown to be valuable in detecting and characterizing tumors in various organs. This study aims to determine whether native T1 relaxation time can serve as a useful tool in distinguishing sarcomas from benign tumors. : In this retrospective study, patients with histologically confirmed soft tissue sarcomas and benign tumors were included.
View Article and Find Full Text PDFObjectives: The aim of this study was to evaluate the diagnostic performance, image quality, and inter- and intra-observer agreement of the 3D T1 multi-echo fast field echo (mFFE) sequence in cervico-thoraco-lumbar vertebral fractures compared with conventional computed tomography (CT) as the gold standard.
Methods: We conducted a prospective single-centre study including 29 patients who underwent spinal magnetic resonance imaging (MRI) at the surgeon's request, in addition to CT for vertebral fracture assessment and classification. A 3D T1 mFFE sequence was added to the standard MRI protocol.
Purpose: Midtarsal injuries are often missed at initial presentation which may lead to long-term complications. Nonetheless, radiographs (XR) are used as a primary imaging method. The place of cone beam computer tomography (CBCT) remains unclear in the management of midfoot injuries.
View Article and Find Full Text PDFCervical foraminal chondromas are benign lesions that may require surgical resection when symptomatic due to radicular and/or spinal cord compression. The aim of surgery is to achieve gross tumor removal while preserving neurological function and spine stability. The authors describe a case of subaxial foraminal chondroma with a systematic review of the literature on patients with cervical chondromas.
View Article and Find Full Text PDFComput Methods Programs Biomed
November 2024
Background And Objective: We develop an efficient deep-learning based dual-domain reconstruction method for sparse-view CT reconstruction with small training parameters and comparable running time. We aim to investigate the model's capability and its clinical value by performing objective and subjective quality assessments using clinical CT projection data acquired on commercial scanners.
Methods: We designed two lightweight networks, namely Sino-Net and Img-Net, to restore the projection and image signal from the DD-Net reconstructed images in the projection and image domains, respectively.
In up to two thirds of prostate-specific membrane antigen (PSMA) PET scans, unspecific bone uptake has been described. The aim of this study was to estimate the diagnostic accuracy of [Ga]Ga-PSMA-11 PET/CT for bone metastases and the occurrence of equivocal lesions. We analyzed retrospectively 118 patients who underwent a [Ga]Ga-PSMA-11 PET/CT for initial staging or recurrence evaluation.
View Article and Find Full Text PDFIEEE Open J Eng Med Biol
June 2024
Purpose: Transducer positioning for liver ablation by magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) is challenging due to the presence of air-filled organs or bones on the beam path. This paper presents a software tool developed to optimize the positioning of a HIFU transducer dedicated to abdominal thermal therapy, to maximize the treatment's efficiency while minimizing the near-field risk.
Methods: A software tool was developed to determine the theoretical optimal position (TOP) of the transducer based on the minimization of a cost function using the particle swarm optimization (PSO).
The emergence of 7T clinical MRI technology has sparked our interest in its ability to discern the complex structures of the hand. Our primary objective was to assess the sensory and motor nerve structures of the hand, specifically nerves and Pacinian corpuscles, with the dual purpose of aiding diagnostic endeavors and supporting reconstructive surgical procedures. Ethical approval was obtained to carry out 7T MRI scans on a cohort of volunteers.
View Article and Find Full Text PDFObjectives: To determine prevalence in the symptomatic population of dorsal mucoid cysts centered on dorsal capsuloscapholunate septum (DCSS) using high-field magnetic resonance imaging (MRI) for anatomoclinical and epidemiological correlations.
Materials And Methods: This single-center retrospective study analyzed all 3-Tesla MRIs consecutively performed for painful wrists in 295 patients. Two blinded readers performed measurements.
With the undeniable increase in asylum requests from unaccompanied alleged minors, age estimation of living individuals has become an essential part of the routine work in European forensic centers. This study aims to review the forensic age estimations performed in our center since 2010, to evaluate the state-of-the-art of this practice in Switzerland with the evolution of the methodology according to upcoming recommendations. Our institute's expert reports performed between 2010 and 2022 were retrospectively analyzed.
View Article and Find Full Text PDFOsteoarthritis (OA) is a prevalent disease and the leading cause of pain, disability, and quality of life deterioration. Our study sought to evaluate the image quality and dose of cone-beam computed tomography arthrography (CBCT-A) and compare them to digital radiography (DR) for OA diagnoses. Overall, 32 cases of CBCT-A and DR with OA met the inclusion criteria and were prospectively analyzed.
View Article and Find Full Text PDFPurpose: This article evaluates the feasibility, safety, and efficacy of MRI-guided lumbar or sacral nerve root infiltration for chronic back pain. We compared the outcomes of our MRI-guided infiltrations with data from CT-guided infiltrations reported in the literature and explored the potential advantages of MRI guidance.
Method: Forty-eight MRI-guided nerve root infiltrations were performed using a 3 T MRI machine.
Background: HIFU ablation of liver malignancies is particularly challenging due to respiratory motion, high tissue perfusion and the presence of the rib cage. Based on our previous development of a super-convergent phased-array transducer, we aimed to further investigate, in vivo, its applicability to deep intrahepatic targets.
Methods: In a series of six pigs, a pseudo-tumor model was used as target, visible both on intra-operatory MRI and post-mortem gross pathology.
Phosphaturic mesenchymal tumor is a rare tumor characterized by paraneoplastic osteomalacia. The diagnosis is often delayed because of nonspecific symptoms and difficulty to localize the tumor. In this study we report a case of PMT of the left femur detected by Ga-68-DOTATATE PET-CT with radiological features mimicking osteoid osteoma.
View Article and Find Full Text PDFThis study describes the anatomy and analyzes the variations of the midsectional morphology of the sigmoid notch. The wrists of 50 patients with suspected scaphoid fracture were evaluated by magnetic resonance imaging (MRI). Sigmoid notch length, volar and dorsal rim heights, insertion length of the volar radioulnar ligament, and Tolat morphology classification were measured on T1-weighted axial plane MRI.
View Article and Find Full Text PDFBi-plane X-ray provides 3D measurements of the lower limb based on the identification of anatomical landmarks in sagittal and frontal X-rays. In clinical practice, such measurements involve multiple operators and sessions. This study aimed at evaluating the reliability of anatomical landmarks identification and geometric parameters of the pelvis and femur measured with bi-plane X-rays before and after total hip arthroplasty (THA).
View Article and Find Full Text PDFObjective: To assess the diagnostic performance of morphological MRI features separately and in combination for distinguishing low- from high-grade soft tissue sarcoma (STS).
Methods And Materials: We retrospectively analysed pre-treatment MRI examinations with T1, T2 with and without fat suppression (FS) and contrast-enhanced T1 obtained in 64 patients with STS categorized histologically as low ( = 21) versus high grade ( = 43). Two musculoskeletal radiologists blinded to histology evaluated MRI features.
Objective: Conventional radiography is the first modality to investigate the radio-ulno-carpal joint in the event of trauma or instability. This study sought to determine the reliability of cone beam computer tomography (CBCT) and scout of view in evaluating carpal alignment compared with conventional radiographs in order to assess the influence of wrist kinematics on usual measurements.
Materials And Methods: We prospectively recruited 305 patients who successively underwent plain radiography and CBCT.
Purpose: High-intensity focused ultrasound (HIFU) is challenging in the liver due to the respiratory motion and risks of near-/far-field burns, particularly on the ribs. We implemented a novel design of a HIFU phased-array transducer, dedicated to transcostal hepatic thermo-ablation. Due to its large acoustic window and strong focusing, the transducer should perform safely for this application.
View Article and Find Full Text PDFGiant cell tumor is a benign epiphyseo-metaphyseal bone tumor affecting the young patient. It is characterized by an extensive osteolysis, a high potential for recurrence, a risk of malignant transformation and pulmonary metastases. Curettage and cavity filling is the most common treatment, even in the case of a pathological fracture.
View Article and Find Full Text PDFInsights Imaging
December 2021
Spinal infections are very commonly encountered by radiologists in their routine clinical practice. In case of typical MRI features, the diagnosis is relatively easy to interpret, all the more so if the clinical and laboratory findings are in agreement with the radiological findings. In many cases, the radiologist is able to make the right diagnosis, thereby avoiding a disco-vertebral biopsy, which is technically challenging and associated with a risk of negative results.
View Article and Find Full Text PDFBackground: For the treatment of radicular pain, nerve root infiltrations can be performed under MRI guidance in select, typically younger, patients where repeated CT exams are not desirable due to associated radiation risk, or potential allergic reactions to iodinated contrast medium.
Methods: Fifteen 3 T MRI-guided nerve root infiltrations were performed in 12 patients with a dedicated surface coil combined with the standard spine coil, using a breathhold PD sequence. The needle artifact on the MR images and the distance between the needle tip and the infiltrated nerve root were measured.