We report on the detection and quantification of aqueous DNA by a fluorophore-induced plasmonic current (FIPC) sensing method. FIPC is a mechanism described by our group in the literature where a fluorophore in close proximity to a plasmonically active metal nanoparticle film (MNF) is able to couple with it, when in an excited state. This coupling produces enhanced fluorescent intensity from the fluorophore-MNF complex, and if conditions are met, a current is generated in the film that is intrinsically linked to the properties of the fluorophore in the complex.
View Article and Find Full Text PDFBackground: Tuberculosis (TB) remains one of the top infectious killers in the world and a prominent fatal disease in developing countries. This study proposes a prototypical solution to early prevention of TB based on its primary symptoms, signs, and risk factors, implemented by means of machine learning (ML) predictive algorithms. Further novelty of the study lies in the uniqueness of patient dataset collected from three top-ranked hospitals of Sindh, Pakistan, a self-administered survey patient-records that comprises a set of questions asked by the doctors treating TB patients in real-time.
View Article and Find Full Text PDFBackground: Lumbar spine surgery is a crucial intervention for addressing spinal injuries or conditions affecting the spine, often involving lumbar fusion through pedicle screw (PS) insertion. The precision of PS placement is pivotal in orthopedic surgery. This systematic review compares the accuracy of robot-guided (RG) surgery with free-hand fluoroscopy-guided (FFG), free-hand without fluoroscopy-guided (FHG), and computed tomography image-guided (CTG) techniques for PS insertion.
View Article and Find Full Text PDFResearch advancement has spurred the usage of electroencephalography (EEG)-based neural oscillatory rhythms as a biomarker to complement clinical rehabilitation strategies for the recovery of motor functions in stroke survivors. However, the inevitable contamination of EEG signals with artifacts from various sources limits its utilization and effectiveness. Thus, the integration of Independent Component Analysis (ICA) and Independent Component Label (ICLabel) has been widely employed to separate neural activity from artifacts.
View Article and Find Full Text PDFIntelligent rehabilitation robotics (RR) have been proposed in recent years to aid post-stroke survivors recover their lost limb functions. However, a large proportion of these robotic systems operate in a passive mode that restricts users to predefined trajectories that rarely align with their intended limb movements, precluding full functional recovery. To address this issue, an efficient Transfer Learning based Convolutional Neural Network (TL-CNN) model is proposed to decode post-stroke patients' motion intentions toward realizing dexterously active robotic training during rehabilitation.
View Article and Find Full Text PDFSurface electromyogram (sEMG) offers a rich set of motor information for decoding limb motion intention that serves as a control input to Intelligent human-machine synergy systems (IHMSS). Despite growing interest in IHMSS, the current publicly available datasets are limited and can hardly meet the growing demands of researchers. This study presents a novel lower limb motion dataset (designated as SIAT-LLMD), comprising sEMG, kinematic, and kinetic data with corresponding labels acquired from 40 healthy humans during 16 movements.
View Article and Find Full Text PDFPreterm birth is a global epidemic affecting millions of mothers across different ethnicities. The cause of the condition remains unknown but has recognised health-based implications, in addition to financial and economic ones. Machine Learning methods have enabled researchers to combine datasets using uterine contraction signals with various forms of prediction machines to improve awareness of the likelihood of premature births.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
April 2023
Early detection and proper treatment of epilepsy is essential and meaningful to those who suffer from this disease. The adoption of deep learning (DL) techniques for automated epileptic seizure detection using electroencephalography (EEG) signals has shown great potential in making the most appropriate and fast medical decisions. However, DL algorithms have high computational complexity and suffer low accuracy with imbalanced medical data in multi seizure-classification task.
View Article and Find Full Text PDFIntroduction: Electromyogram-based pattern recognition (EMG-PR) has been widely considered an essentially intuitive control method for multifunctional upper limb prostheses. A crucial aspect of the scheme is the EMG signal recording duration (SRD) from which requisite motor tasks are characterized per time, impacting the system's overall performance. For instance, lengthy SRD inevitably introduces fatigue (that alters the muscle contraction patterns of specific limb motions) and may incur high computational costs in building the motion intent decoder, resulting in inadequate prosthetic control and controller delay in practical usage.
View Article and Find Full Text PDFSurface electromyogram (sEMG) is arguably the most sought-after physiological signal with a broad spectrum of biomedical applications, especially in miniaturized rehabilitation robots such as multifunctional prostheses. The widespread use of sEMG to drive pattern recognition (PR)-based control schemes is primarily due to its rich motor information content and non-invasiveness. Moreover, sEMG recordings exhibit non-linear and non-uniformity properties with inevitable interferences that distort intrinsic characteristics of the signal, precluding existing signal processing methods from yielding requisite motor control information.
View Article and Find Full Text PDFSynergetic recovery of both somatosensory and motor functions is highly desired by limb amputees to fully regain their lost limb abilities. The commercially available prostheses can restore the lost motor function in amputees but lack intuitive sensory feedback. The previous studies showed that electrical stimulation on the arm stump would be a promising approach to induce sensory information into the nervous system, enabling the possibility of realizing sensory feedback in limb prostheses.
View Article and Find Full Text PDFMulti-channel Electroencephalograph (EEG) signal is an important source of neural information for motor imagery (MI) limb movement intent decoding. The decoded MI movement intent often serve as potential control input for brain-computer interface (BCI) based rehabilitation robots. However, the presence of multiple dynamic artifacts in EEG signal leads to serious processing challenge that affects the BCI system in practical settings.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
November 2021
Features extracted from the surface electromyography (sEMG) signals during the speaking tasks play an essential role in sEMG based speech recognition. However, currently there are no general rules on the optimal choice of sEMG features to achieve satisfactory performance. In this study, a total of 120 electrodes were placed on the face and neck muscles to record the high-density (HD) sEMG signals when subjects spoke ten digits in English.
View Article and Find Full Text PDFThe measurement of cardiac blood flow vortex characteristics can help to facilitate the analysis of blood flow dynamics that regulates heart function. However, the complexity of cardiac flow along with other physical limitations makes it difficult to adequately identify the dominant vortices in a heart chamber, which play a significant role in regulating the heart function. Although the existing vortex quantification methods can achieve this goal, there are still some shortcomings: such as low precision, and ignoring the center of the vortex without the description of vortex deformation processes.
View Article and Find Full Text PDFTowards eliminating stimulus artifacts, alternating polarity stimuli have been widely adopted in eliciting the auditory brainstem response. However, considering the difference in the physiologic basis of the positive and negative polarity stimuli on the auditory system, it is unclear whether alternating polarity stimuli would adversely affect the auditory brainstem response characteristics. This research proposes a new polarity method for stimulus artifacts elimination, Sum polarity, that separately utilized the rarefaction and condensation stimuli and then summed the two evoked responses.
View Article and Find Full Text PDFThe formation of vortex rings in the left ventricular (LV) blood flow is a mechanism for optimized blood transport from the mitral valve inlet to aortic valve outlet, and the vorticity is an important measure of a well-functioning LV. However, due to lack of quantitative methods, the process of defining the boundary of a vortex in the LV and identifying the dominant vortex components has not been studied previously. The Lagrangian-averaged vorticity deviation (LAVD) can enable us to compute the trajectory integral of the normed difference of the vorticity from its spatial mean.
View Article and Find Full Text PDFBackground And Objective: Non-invasive multichannel Electroencephalography (EEG) recordings provide an alternative source of neural information from which motor imagery (MI) patterns associated with limb movement intent can be decoded for use as control inputs for rehabilitation robots. The presence of multiple inherent dynamic artifacts in EEG signals, however, poses processing challenges for brain-computer interface (BCI) systems. A large proportion of the existing EEG signal preprocessing methods focus on isolating single artifact per time from an ensemble of EEG trials and require calibration and/or reference electrodes, resulting in increased complexity of their application to MI-EEG controlled rehabilitation devices in practical settings.
View Article and Find Full Text PDFBackground And Objective: Recognition of motor intention based on electroencephalogram (EEG) signals has attracted considerable research interest in the field of pattern recognition due to its notable application of non-muscular communication and control for those with severe motor disabilities. In analysis of EEG data, achieving a higher classification performance is dependent on the appropriate representation of EEG features which is mostly characterized by one unique frequency before applying a learning model. Neglecting other frequencies of EEG signals could deteriorate the recognition performance of the model because each frequency has its unique advantages.
View Article and Find Full Text PDF. The auditory brainstem response (ABR) audiometry is a means of assessing the functional status of the auditory neural pathway in the clinic. The conventional click ABR test lacks good neural synchrony and it mainly evaluates high-frequency hearing while the common tone-burst ABR test only detects hearing loss of a certain frequency at a time.
View Article and Find Full Text PDFAlthough short tandem repeat (STR) analysis is available as a reliable method for the determination of the genetic origin of cell lines, the occurrence of misauthenticated cell lines remains an important issue. Reasons include the cost, effort and time associated with STR analysis. Moreover, there are currently no methods for the discrimination between isogenic cell lines (cell lines of the same genetic origin, e.
View Article and Find Full Text PDF. Silent speech recognition (SSR) based on surface electromyography (sEMG) is an attractive non-acoustic modality of human-machine interfaces that convert the neuromuscular electrophysiological signals into computer-readable textual messages. The speaking process involves complex neuromuscular activities spanning a large area over the facial and neck muscles, thus the locations of the sEMG electrodes considerably affected the performance of the SSR system.
View Article and Find Full Text PDFUpper extremity motor function loss severely affects stroke survivors during daily life activities. Different rehabilitation robotic systems have been developed to allow stroke survivors regain their motor function. Meanwhile, most of the robots only operate in a passive mode and restrict the users to navigate predefined trajectories which may not align with their motion intent, thus limiting motor recovery.
View Article and Find Full Text PDF