Occult hemorrhages after trauma can be present insidiously, and if not detected early enough can result in patient death. This study evaluated a hemorrhage model on 18 human subjects, comparing the performance of traditional vital signs to multiple off-the-shelf non-invasive biomarkers. A validated lower body negative pressure (LBNP) model was used to induce progression towards hypovolemic cardiovascular instability.
View Article and Find Full Text PDFAnalyze the performance of electrical impedance tomography (EIT) in an innovative porcine model of subclinical hemorrhage and investigate associations between EIT and hemodynamic trends.. Twenty-five swine were bled at slow rates to create an extended period of subclinical hemorrhage during which the animal's heart rate (HR) and blood pressure (BP) remained stable from before hemodynamic deterioration, where stable was defined as <15% decrease in BP and <20% increase in HRi.
View Article and Find Full Text PDF