Publications by authors named "Samoylova L"

X-ray multi-projection imaging (XMPI) is an emerging experimental technique for the acquisition of rotation-free, time-resolved, volumetric information on stochastic processes. The technique is developed for high-brilliance light-source facilities, aiming to address known limitations of state-of-the-art imaging methods in the acquisition of 4D sample information, linked to their need for sample rotation. XMPI relies on a beam-splitting scheme, that illuminates a sample from multiple, angularly spaced viewpoints, and employs fast, indirect, X-ray imaging detectors for the collection of the data.

View Article and Find Full Text PDF

X-ray multi-projection imaging (XMPI) has the potential to provide rotation-free 3D movies of optically opaque samples. The absence of rotation enables superior imaging speed and preserves fragile sample dynamics by avoiding the centrifugal forces introduced by conventional rotary tomography. Here, we present our XMPI observations at the ID19 beamline (ESRF, France) of 3D dynamics in melted aluminum with 1000 frames per second and 8 µm resolution per projection using the full dynamical range of our detectors.

View Article and Find Full Text PDF

Among the vascular prostheses used for aortic replacement, 95% are woven or knitted grafts from polyester fibers. Such grafts require sealing, for which gelatin (Gel) is most often used. Sometimes antibiotics are added to the sealant.

View Article and Find Full Text PDF

The SASE3 soft X-ray beamline at the European XFEL has been designed and built to provide experiments with a pink or monochromatic beam in the photon energy range 250-3000 eV. Here, the focus is monochromatic operation of the SASE3 beamline, and the design and performance of the SASE3 grating monochromator are reported. The unique capability of a free-electron laser source to produce short femtosecond pulses of a high degree of coherence challenges the monochromator design by demanding control of both photon energy and temporal resolution.

View Article and Find Full Text PDF

Due to the high intensity and MHz repetition rate of photon pulses generated by the European X-ray Free-Electron Laser, the heat load on silicon crystal monochromators can become large and prevent ideal transmission in Bragg diffraction geometry due to crystal deformation. Here, we present experimental data illustrating how heat load affects the performance of a cryogenically cooled monochromator under such conditions. The measurements are in good agreement with a depth-uniform model of X-ray dynamical diffraction taking beam absorption and heat deformation of the crystals into account.

View Article and Find Full Text PDF

The resolution function of a spectrometer based on a strongly bent single crystal (bending radius of 10 cm or less) is evaluated. It is shown that the resolution is controlled by two parameters: (i) the ratio of the lattice spacing of the chosen reflection to the crystal thickness and (ii) a single parameter comprising crystal thickness, its bending radius, distance to a detector, and anisotropic elastic constants of the chosen crystal. The results allow the optimization of the parameters of bent-crystal spectrometers for the hard X-ray free-electron laser sources.

View Article and Find Full Text PDF

For the High-Energy-Density (HED) beamline at the SASE2 undulator of the European XFEL, a hard X-ray split-and-delay unit (SDU) has been built enabling time-resolved pump/probe experiments with photon energies between 5 keV and 24 keV. The optical layout of the SDU is based on geometrical wavefront splitting and multilayer Bragg mirrors. Maximum delays between Δτ = ±1 ps at 24 keV and Δτ = ±23 ps at 5 keV will be possible.

View Article and Find Full Text PDF

The use of strongly bent crystals in spectrometers for pulses of a hard X-ray free-electron laser is explored theoretically. Diffraction is calculated in both dynamical and kinematical theories. It is shown that diffraction can be treated kinematically when the bending radius is small compared with the critical radius given by the ratio of the Bragg-case extinction length for the actual reflection to the Darwin width of this reflection.

View Article and Find Full Text PDF

Self-amplified spontaneous emission (SASE) enables X-ray free-electron lasers (XFELs) to generate hard X-ray pulses of sub-100 fs duration. However, due to the stochastic nature of SASE, the energy spectrum fluctuates from pulse to pulse. Many experiments that employ XFEL radiation require the resolution of the spectrum of each pulse.

View Article and Find Full Text PDF

Wavefront-propagation simulations have been performed to complete the design of a monochromator beamline for FLASH2, the variable-gap undulator line at the soft X-ray free-electron laser in Hamburg (FLASH). Prior to propagation through the beamline optical elements, the parameters of the photon source were generated using the GENESIS code which includes the free-electron laser experimental data. Threshold tolerances for the misalignment of mirror angles are calculated and, since diffraction effects were included in the simulations, the minimum quality with respect to the slope errors required for the optics is determined.

View Article and Find Full Text PDF

SASE1 is the first beamline of the European XFEL that became operational in 2017. It consists of the SASE1 undulator system, the beam transport system, and the two scientific experiment stations: Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX), and Femtosecond X-ray Experiments (FXE). The beam transport system comprises mirrors to offset and guide the beam to the instruments and a set of X-ray optical components to align, manipulate and diagnose the beam.

View Article and Find Full Text PDF

This study theoretically analyzes an increase in X-ray absorption by a grazing incidence mirror due to its surface roughness. We demonstrate that the increase in absorption can be several hundred times larger than predicted by the Nevot-Croce formula. As a result, absorption enhances by several times compared to a perfectly smooth mirror despite the extremely small grazing angle of an incident X-ray beam (a fraction of the critical angle of the total external reflection) and the high quality of the reflecting surface (the roughness height was 0.

View Article and Find Full Text PDF

A precise spectral characterization of every single pulse is required in many x-ray free-electron laser (XFEL) experiments due to the fluctuating spectral content of self-amplified spontaneous emission (SASE) beams. Bent single-crystal spectrometers can provide sufficient spectral resolution to resolve the SASE spikes while also covering the full SASE bandwidth. To better withstand the high heat load induced by the 4.

View Article and Find Full Text PDF
Article Synopsis
  • Single-particle imaging with X-ray free-electron lasers (XFELs) can reveal atomic-level structures of non-crystalline biomolecules, even with radiation damage.
  • The study investigates how different pulse durations affect the quality of diffraction data in imaging experiments.
  • Results suggest that the best pulse duration for accurately imaging molecules with a few thousand atoms, at 5 keV, is between 3 and 9 femtoseconds (fs).
View Article and Find Full Text PDF

This article describes the () package, a new interactive software framework for coherent and partially coherent X-ray wavefront propagation simulations. The package has been developed at European XFEL for users at the existing and emerging free-electron laser (FEL) facilities, as well as at the third-generation synchrotron sources and future diffraction-limited storage rings. The addresses the needs of beamline scientists and user groups to facilitate the design, optimization and improvement of X-ray optics to meet their experimental requirements.

View Article and Find Full Text PDF

The advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy and incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. We demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL.

View Article and Find Full Text PDF

A new phenomenon on X-ray optics surfaces has been observed: the growth of nano-dots (40-55 nm diameter, 8-13 nm height, 9.4 dots µm(-2) surface density) on the grazing-incidence mirror surface under irradiation by the free-electron laser (FEL) FLASH (5-45 nm wavelength, 3° grazing-incidence angle). With a model calculation it is shown that these nano-dots may occur during the growth of a contamination layer due to polymerization of incoming hydrocarbon molecules.

View Article and Find Full Text PDF

The use of soft X-rays near the carbon edge of absorption (270-300 eV) greatly enhances studies in various branches of science. However, the choice of reflecting coatings for mirrors operating in free-electron and X-ray free-electron laser (FEL and XFEL) beamlines in this spectral range is not so evident and experimental justifications of the mirror efficiency are rather limited. In the present paper it is demonstrated experimentally that the reflectivity of B4C- and Ni-coated grazing-incidence mirrors is high enough for their operation in FEL or XFEL beamlines near the carbon K-edge of absorption.

View Article and Find Full Text PDF

The high photon flux and femtosecond pulse duration of hard X-ray free-electron lasers have spurred a large variety of novel and fascinating experiments in physical, chemical and biological sciences. Many of these experiments depend fundamentally on a clean, well-defined wavefront. Here we explore the wavefront properties of hard X-ray free-electron laser radiation by means of a grating interferometer, from which we obtain shot-to-shot wavefront information with an excellent angular sensitivity on the order of ten nanoradian.

View Article and Find Full Text PDF

A growing number of X-ray sources based on the free-electron laser (XFEL) principle are presently under construction or have recently started operation. The intense, ultrashort pulses of these sources will enable new insights in many different fields of science. A key problem is to provide x-ray optical elements capable of collecting the largest possible fraction of the radiation and to focus into the smallest possible focus.

View Article and Find Full Text PDF