New particle formation (NPF) is considered a major source of aerosol particles and cloud condensation nuclei (CCN); however, our understanding of NPF and the subsequent particle growth mechanisms in coastal areas remains limited. This study provides evidence of frequent NPF events followed by particle growth in the middle Adriatic Sea during the summer months at the coastal station of Rogoznica in Croatia. To our knowledge, this is the first study to report such events in this region.

View Article and Find Full Text PDF

Rapid and reliable immunosensing is undoubtedly one of the priorities in the efficient management and combat against a pandemic, as society has experienced with the SARS-CoV-2 outbreak; simple and cost-effective sensing strategies are at the forefront of these efforts. In this regard, 2D-layered MXenes hold great potential for electrochemical biosensing due to their attractive physicochemical properties. Herein, we present a VCT MXene-based sensing layer as an integral part of a label-free immunosensor for sensitive and selective detection of the SARS-CoV-2 spike protein.

View Article and Find Full Text PDF

Listeriosis is one of the most serious foodborne diseases caused by the intracellular bacterium Listeria monocytogenes. Its two major virulence factors, broad-range phospholipase C (LmPC-PLC) and the pore-forming toxin listeriolysin O (LLO), enable the bacterium to spread in the host by destroying cell membranes. Here, we determine the crystal structure of LmPC-PLC and complement it with the functional analysis of this enzyme.

View Article and Find Full Text PDF

The development of sensitive, selective, and reliable gaseous hydrogen peroxide (HO) sensors operating at room temperature still represents a remaining challenge. In this work, we have investigated and combined the advantageous properties of a two-dimensional TiCT MXene material that exhibits a large specific surface area and high surface activity, with favorable conducting and stabilizing properties of chitosan. The MXene-chitosan membrane was deposited on the ferrocyanide-modified screen-printed working carbon electrode, followed by applying poly(acrylic acid) as an electrolyte and accumulation medium for gaseous HO.

View Article and Find Full Text PDF

The preconditioning and modification of the supporting electrode surface is an essential step in every biosensor architecture. In particular, when using screen-printed carbon electrodes (SPEs) as inexpensive and convenient disposable sensor substrates, their somewhat lower electrochemical (surface) reproducibility might represent a complex hurdle. Herein, we investigated the effect of selected preconditioning strategies, such as cyclic voltammetric pretreatment, in HSO and HO and plasma pretreatment with a positive and negative glow discharge, which all improved the electrochemical stability of the unmodified SPEs.

View Article and Find Full Text PDF

Atmospheric gases and particulate matter (PM) in contact with the material's surface lead to chemical and physical changes, which in most cases cause degradation of the cultural heritage material. Atmospheric damage and soiling are recognized as two pivotal forms of deterioration of cultural heritage materials caused by air pollution. However, the atmospheric damage effect of PM is rather complicated; its variable composition accelerates the deterioration process.

View Article and Find Full Text PDF

The detection of volatile organic compounds with electrochemical gas sensors is still very challenging regarding their sensitivity, selectivity, and operation at room temperature. There is a need for robust, sensitive, inexpensive, and yet easy-to-operate sensors for phenol and other phenolic compounds that function reliably under ambient conditions. Herein, we present a phenol gas sensor based on a combination of a semisolid, alkaline sodium polyacrylate, and commercial screen-printed electrodes.

View Article and Find Full Text PDF

Progesterone is an important hormone responsible, among others, for maintaining pregnancy via inhibition of uterus muscles activity; thus, following its concentration levels in pregnant women is of immense importance in the endeavor to prevent premature birth. In this work, the nanostructured bismuth film electrode (nsBiFE) was studied for detection of progesterone in neutral medium. Due to the ability to accumulate progesterone at the nsBiFE, the adsorptive cathodic stripping voltammetry was beneficially exploited.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the impact of low concentrations of silver nanoparticles (AgNPs) on the digestive glands of terrestrial isopods (Porcellio scaber) through various advanced analytical techniques.
  • Despite no observed toxicity in the isopods after 14 days of exposure, changes were detected at the tissue level, indicating that AgNPs interact with biological tissues without affecting the overall health of the organisms.
  • The extent of these effects varied based on the AgNPs' characteristics, including their shape, size, concentration, and the release of ions from the particles.
View Article and Find Full Text PDF

Iridium-based particles, regarded as the most promising proton exchange membrane electrolyzer electrocatalysts, were investigated by transmission electron microscopy and by coupling of an electrochemical flow cell (EFC) with online inductively coupled plasma mass spectrometry. Additionally, studies using a thin-film rotating disc electrode, identical location transmission and scanning electron microscopy, as well as X-ray absorption spectroscopy have been performed. Extremely sensitive online time-and potential-resolved electrochemical dissolution profiles revealed that Ir particles dissolve well below oxygen evolution reaction (OER) potentials, presumably induced by Ir surface oxidation and reduction processes, also referred to as transient dissolution.

View Article and Find Full Text PDF

In the present study, we evaluated the roles that ZnO particle size and Zn ion release have on cyto- and genotoxicity in vitro. The Madin-Darby canine kidney (MDCK) cells were treated with ZnO nanoparticles (NPs), ZnO macroparticles (MPs), and ZnCl as a source of free Zn ions. We first tested cytotoxicity to define sub-cytotoxic exposure concentrations and afterwards we performed alkaline comet and cytokinesis-block micronucleus assays.

View Article and Find Full Text PDF

We assessed the bioavailability of Ag from Ag nanoparticles (NPs), stabilized with polyvinylpyrrolidone (PVP), to terrestrial isopods which were exposed to 10, 100 and 1000 μg Ag NPs/g of dry food. Different Ag species were determined in the NP suspension that was fed to isopods: (i) total Ag by atomic absorption spectroscopy, (ii) the sum of Ag-PVP complexes and free Ag by anodic stripping voltammetry at the bismuth-film electrode, and (iii) free Ag by ion-selective potentiometry. The amounts of Ag species in the consumed food were compared to the masses of Ag accumulated in the isopod digestive glands.

View Article and Find Full Text PDF

New insights into the functioning, i.e. electrochemical behaviour and analytical performance, of in situ prepared antimony film electrodes (SbFEs) under square-wave anodic stripping (SW-ASV) and cyclic (CV) voltammetry conditions are presented by studying several key operational parameters using Pb(II), Cd(II) and Zn(II) as model analyte ions.

View Article and Find Full Text PDF

A mechanistic study to provide diagnostics of anodic stripping electrode processes at bismuth-film electrodes is presented from both theoretical and experimental points of view. Theoretical models for three types of electrode mechanisms are developed under conditions of square-wave voltammetry, combining rigorous modeling based on integral equations and the step function method, resulting in derivation of a single numerical recurrent formula to predict the outcome of the voltammetric experiment. In the course of the deposition step, it has been assumed that a uniform film of the metal analyte is formed on the bismuth substrate, in situ deposited onto a glassy carbon electrode surface, without considering mass transfer within either the bismuth or the metal analyte film.

View Article and Find Full Text PDF

This article reports on a novel microsensor for amperometric measurement of ascorbic acid (AA) under acidic conditions (pH 2) based on a carbon fiber microelectrode (CFME) modified with nickel oxide and ruthenium hexacyanoferrate (NiO-RuHCF). This sensing layer was deposited electrochemically in a two-step procedure involving an initial galvanostatic NiO deposition followed by a potentiodynamic RuHCF deposition from solutions containing the precursor salts. Several important parameters were examined to characterize and optimize the NiO-RuHCF sensing layer with respect to its current response to AA by using cyclic voltammetry, and scanning electron microscopy-energy dispersive X-ray spectroscopy methods.

View Article and Find Full Text PDF

The present paper demonstrates the preparation and characterization of micro-electrodes based on carbon paste which is composed of carbon nanoparticles with an average diameter of 30 nm and binding oil. The carbon paste electrode material is encased in pulled glass capillaries ranging in diameter from several tens down to less than ten micro-meters (r=4.5 microm).

View Article and Find Full Text PDF

In this work, an antimony film electrode (SbFE) is reported for the first time as a possible alternative for electrochemical stripping analysis of trace heavy metals. The SbFE was prepared in situ on a glassy carbon substrate electrode and employed in combination with either anodic stripping voltammetry or stripping chronopotentiometry in nondeaerated solutions of 0.01 M hydrochloric acid (pH 2).

View Article and Find Full Text PDF

The bismuth film electrode (BiFE), in combination with anodic stripping voltammetry, offers convenient measurement of low concentrations of tin. The procedure involves simultaneous in situ formation of the bismuth film electrode on a glassy carbon substrate electrode, together with electrochemical deposition of tin, in a non-deaerated model solution containing bismuth ions, catechol as complexing agent and the metal analyte, followed by an anodic stripping scan. The BiFE is characterized by an attractive electroanalytical performance, with two distinct voltammetric stripping signals corresponding to tin, accompanied with low background contributions.

View Article and Find Full Text PDF

A new sol-gel precursor, based on 1-methyl-3-[3-(trimethoxy-lambda(4)-silyl)propyl]imidazolium iodide (MTMSPI(+)I(-)), was synthesized and investigated as a potential novel quasi-solid-state ionic liquid redox electrolyte for dye-sensitized photoelectrochemical (DSPEC) cells of the Graetzel type. MTMSPI(+)I(-) was hydrolyzed with acidified water, and the reaction products of the sol-gel condensation reactions were assessed with the help of (29)Si NMR and infrared spectroscopic techniques. Results of time-dependent analyses showed the formation of a positively charged polyhedral cubelike silsesquioxane species, which still contained a small amount of silanol end groups that were removed after heating at 200 degrees C.

View Article and Find Full Text PDF

The in vivo performance of a voltammetric microprobe based on overoxidized poly(1,2-phenylenediamine) coated carbon fiber microelectrode (OPPD/CFME), developed in our laboratory, is presented. For this purpose, an OPPD microprobe was stereotaxicaly implanted in the striatum of a deeply anesthetized Wistar rat for the simultaneous measurement of dopamine, serotonin and ascorbate. Furthermore, the post mortem levels of these physiologically important compounds were monitored after the rats were terminated with an overdose of anesthetic introduced through an indwelling jugular catheter.

View Article and Find Full Text PDF

Electrochemically modified screen-printed carbon electrode (SPCE) has been prepared by electrodepositing nickel hexacyanoferrate(III) (NiHCF) onto the electrode surface using cyclic voltammetry (CV). The performance of NiHCF-SPCE sensor was characterized and optimized by controlling several operational parameters. The NiHCF film has been proven to remain stable after CV scanning from 0 to +1.

View Article and Find Full Text PDF

The testing of various types of carbon paste electrodes (CPEs) for their use in stripping potentiometry was carried out by means of specially proposed procedures and by using various model analyte systems. CPEs containing three different pasting liquids (paraffin oil, silicone oil, tricresyl phosphate) were tested as supports for mercury- and gold films, and as substrates for electrolytic, adsorptive, ion-pair forming, and extractive accumulation. Test measurements in organic solvent-containing media and studies of some irreversible electrochemical reactions were performed as well.