Background: Secretoneurin, a member of the granin protein family, is associated with the risk of mortality in patients with acute and chronic heart failure. Secretoneurin may play an important role in cardiomyocyte calcium handling, suggesting that it may influence cardiac arrhythmia risk. We hypothesized that baseline and serial measurements of circulating secretoneurin are associated with the risk of incident ventricular tachyarrhythmias (VA) and death, and that serial measurement would provide prognostic information beyond baseline values.
View Article and Find Full Text PDFImportance: Atrial fibrillation and obesity are common, and both are increasing in prevalence. Obesity is associated with failure of cardioversion of atrial fibrillation using a standard single set of defibrillator pads, even at high output.
Objective: To compare the efficacy and safety of dual direct-current cardioversion (DCCV) using 2 sets of pads, with each pair simultaneously delivering 200 J, with traditional single 200-J DCCV using 1 set of pads in patients with obesity and atrial fibrillation.
Introduction: Guidelines indicate primary-prevention implantable cardioverter-defibrillators (ICDs) for most patients with left ventricular ejection fraction (LVEF) ≤ 35%. Some patients' LVEFs improve during the life of their first ICD. In patients with recovered LVEF who never received appropriate ICD therapy, the utility of generator replacement upon battery depletion remains unclear.
View Article and Find Full Text PDFIntroduction: Use of a novel magnetic sensor enabled optical contact force ablation catheter has been established to be safe and effective for treatment of symptomatic drug-refractory paroxysmal atrial fibrillation (AF) but has yet to be demonstrated in the persistent AF (PersAF) population.
Methods: PERSIST-END was a multicenter, prospective, nonrandomized, investigational study designed to demonstrate the safety and effectiveness of TactiCath™ Ablation Catheter, Sensor Enabled™(SE) (TactiCath SE) for use in the treatment of subjects with documented PersAF refractory or intolerant to at least one Class I/III AAD. The ablation strategy included pulmonary vein isolation and additional targets at physician discretion.
Introduction: Heart failure (HF) is a major cause of morbidity and mortality, with nearly half of all HF-related deaths resulting from sudden cardiac death (SCD), most often from an arrhythmic event. The pathophysiologic changes that occur in response to the hemodynamic stress of HF may lead to increased arrhythmogenesis. Theoretically, medications that block these arrhythmogenic substrates would decrease the risk of SCD.
View Article and Find Full Text PDFAtrial Fibrillation (AF) and heart failure (HF) with reduced ejection fraction (HFrEF) frequently coexist, resulting in significant morbidity and mortality. Therapeutic options for patients with AF and HFrEF are limited due to few antiarrhythmic drug (AAD) choices and historically equivocal effects of procedural interventions on mortality. However, recent randomized trials examining catheter ablation (CA) in AF patients with HFrEF have shown a beneficial effect on arrhythmic burden and HF symptoms, as well as an improvement in mortality.
View Article and Find Full Text PDFAortic stenosis is the most common valvulopathy requiring replacement by means of the surgical or transcatheter approach. Transcatheter aortic valve replacement (TAVR) has quickly become a viable and often preferred treatment strategy compared to surgical aortic valve replacement. However, transcatheter heart valve system deployment not infrequently injures the specialized electrical system of the heart, leading to new conduction disorders including high-grade atrioventricular block and complete heart block (CHB) necessitating permanent pacemaker implantation (PPI), which may lead to deleterious effects on cardiac function and patient outcomes.
View Article and Find Full Text PDFAims: Evidence links markers of systemic inflammation and heart failure (HF) with ventricular arrhythmias (VA) and/or death. Biomarker levels, and the risk they indicate, may vary over time. We evaluated the utility of serial laboratory measurements of inflammatory biomarkers and HF, using time-dependent analysis.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
July 2020
Introduction: Sudden cardiac death is a substantial cause of mortality in patients with cardiomyopathy, but evidence supporting implantable cardioverter-defibrillator (ICD) implantation is less robust in nonischemic cardiomyopathy (NICM) than in ischemic cardiomyopathy. Improved risk stratification is needed. We assessed whether absolute quantification of stress myocardial blood flow (sMBF) measured by positron emission tomography (PET) predicts ventricular arrhythmias (VA) and/or death in patients with NICM.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
March 2020
Background: Class 1C antiarrhythmic drugs (AADs) are effective first-line agents for atrial fibrillation (AF) treatment. However, these agents commonly are avoided in patients with known coronary artery disease (CAD), due to known increased risk in the postmyocardial infarction population. Whether 1C AADs are safe in patients with CAD but without clinical ischemia or infarct is unknown.
View Article and Find Full Text PDFAims: Several published investigations demonstrated that a longer T-peak to T-end interval (Tpe) implies increased risk for ventricular tachyarrhythmia (VT/VF) and mortality. Tpe has been measured using diverse methods. We aimed to determine the optimal Tpe measurement method for screening purposes.
View Article and Find Full Text PDFBackground: Following revascularization, most payors require 3 months of medical therapy, followed by left ventricular ejection fraction (LVEF) reassessment, before implantable cardioverter-defibrillator (ICD) implantation possibly contributing to incomplete follow-up and suboptimal utilization of ICD therapy. The natural history of these patients, and their fate regarding ICD implantation, is unknown.
Hypothesis: We hypothesized that a waiting period after revascularization for stable CAD results in missed opportunities to provide care with regard to ICD implantation.
Background: The electrocardiographic T-wave peak to T-wave end interval (Tpe) correlates with dispersion of ventricular repolarization (DVR). Increased DVR increases propensity toward electrical reentry that can cause ventricular tachyarrhythmia. The baseline rate-corrected Tpe (Tpec) has been shown to predict ventricular tachyarrhythmia and death in multiple patient populations but not among cardiomyopathic patients undergoing insertion of an implantable cardioverter-defibrillator (ICD) for primary prevention.
View Article and Find Full Text PDFAtrial fibrillation (AF) is the most common arrhythmia worldwide; it is a significant risk factor for stroke and embolization, and has an impact on cardiac function. Despite its impact on morbidity and mortality, our understanding of the etiology and pathophysiology of this disease process is still incomplete. Over the past several decades, there has been evidence to suggest that AF has a significant correlation with metabolic syndrome (MetS).
View Article and Find Full Text PDFAtrial fibrillation (AF) is the most common arrhythmia worldwide, and it has a significant effect on morbidity and mortality. It is a significant risk factor for stroke and peripheral embolization, and it has an effect on cardiac function. Despite widespread interest and extensive research on this topic, our understanding of the etiology and pathogenesis of this disease process is still incomplete.
View Article and Find Full Text PDFAtrial fibrillation (AF) is a major risk factor for stroke and systemic embolization, particularly in the elderly. Approximately 2.3 million adults in the United States have AF, and it is projected that this number will increase to approximately 5.
View Article and Find Full Text PDFAims: The interval between the T-wave's peak and end (Tpe), an electrocardiographic (ECG) index of ventricular repolarization, has been proposed as an indicator of arrhythmic risk. We aimed to clarify the clinical usefulness of Tpe for risk stratification.
Methods And Results: We evaluated 327 patients with left ventricular ejection fraction (LVEF) ≤ 35% (75% male, LVEF 23 ± 7%).
The fibrillin defect central to Marfan syndrome is believed to affect myocardial conduction and predispose affected patients to various arrhythmias, including ventricular tachycardia, atrial fibrillation, and atrioventricular nodal reentry tachycardia. Here we describe an adult Marfan patient with atrial ectopic tachycardia. To our knowledge, this is the first reported case of atrial ectopic tachycardia in the setting of Marfan syndrome.
View Article and Find Full Text PDFJ.V. is a 3(1/2)-year-old patient with left ventricular fascicular ventricular tachycardia that had been well controlled on verapamil for 3 years.
View Article and Find Full Text PDFSystolic heart failure is a major problem for Americans today, with 550,000 new cases diagnosed per year, and ultimately contributes to 287,000 deaths annually. While pharmacologic therapy has drastically improved outcomes in patients with systolic heart failure, hospitalizations from systolic heart failure continue to increase and remain a major cost burden. In response to this unmet need, recent years have seen dramatic improvements in device-based therapy targeting one cause of systolic dysfunction: dyssynchronous ventricular contraction.
View Article and Find Full Text PDF