Chronic respiratory diseases affect millions and are leading causes of death in the US and worldwide. Pulmonary auscultation provides clinicians with critical respiratory health information through the study of Lung Sounds (LS) and the context of the breathing-phase and chest location in which they are measured. Existing auscultation technologies, however, do not enable the simultaneous measurement of this context, thereby potentially limiting computerized LS analysis.

View Article and Find Full Text PDF

Objective: Muscle health and decreased muscle performance (fatigue) quantification has proven to be an invaluable tool for both athletic performance assessment and injury prevention. However, existing methods estimating muscle fatigue are infeasible for everyday use. Wearable technologies are feasible for everyday use and can enable discovery of digital biomarkers of muscle fatigue.

View Article and Find Full Text PDF

Objective: Musculoskeletal health monitoring is limited in everyday settings where patient symptoms can substantially change - delaying treatment and worsening patient outcomes. Wearable technologies aim to quantify musculoskeletal health outside clinical settings but sensor constraints limit usability. Wearable localized multi-frequency bioimpedance assessment (MFBIA) shows promise for tracking musculoskeletal health but relies on gel electrodes, hindering extended at-home use.

View Article and Find Full Text PDF

In recent years, wearable mid-activity electrical bioimpedance (EBI) sensing has been used to non-invasively track changes in edema and swelling levels within human joints. While the physiological origin of the changes in mid-activity EBI measurements have been demonstrated, EBI waveform patterns during activity have not been explored. In this work, we present a novel approach to extract waveform features from EBI measurements during gait to estimate the changes in vertical ground reaction forces (vGRF) corresponding to fatigue.

View Article and Find Full Text PDF

Objective: Rheumatoid arthritis (RA) is a chronic inflammatory syndrome that features painful and destructive joint disease. Aggressive disease-modifying treatment can result in reduced symptoms and protection from irreversible joint damage; however, assessment of treatment efficacy is currently based largely on subjective measures of patient and physician impressions. In this work, we address this compelling need to provide an accurate and quantitative capability for monitoring joint health in patients with RA.

View Article and Find Full Text PDF

Heart failure (HF) exacerbations, characterized by pulmonary congestion and breathlessness, require frequent hospitalizations, often resulting in poor outcomes. Current methods for tracking lung fluid and respiratory distress are unable to produce continuous, holistic measures of cardiopulmonary health. We present a multimodal sensing system that captures bioimpedance spectroscopy (BIS), multi-channel lung sounds from four contact microphones, multi-frequency impedance pneumography (IP), temperature, and kinematics to track changes in cardiopulmonary status.

View Article and Find Full Text PDF

Developments in wearable technologies created opportunities for non-invasive joint health assessment while subjects perform daily activities during rehabilitation and recovery. However, existing state-of-art solutions still require a health professional or a researcher to set up the device, and most of them are not convenient for at-home use. In this paper, we demonstrate the latest version of the multimodal knee brace that our lab previously developed.

View Article and Find Full Text PDF

Objective: Evaluating convenient, wearable multi-frequency impedance pneumography (IP)-based respiratory monitoring in ambulatory persons with novel electrode positioning.

Methods: A wearable multi-frequency IP system was utilized to estimate tidal volume (TV) and respiratory timings in 14 healthy subjects. A 5.

View Article and Find Full Text PDF

To present a robust methodology for evaluating ankle health during ambulation using a wearable device. Methods: We developed a novel data capture system that leverages changes within the ankle during ambulation for real-time tracking of bioimpedance. The novel analysis compares the range of reactance at 5 kHz to the range of reactance at 100 kHz; which removes the technique's previous reliance on a known baseline.

View Article and Find Full Text PDF

Objective: We present a robust methodology for tracking ankle edema longitudinally based on bioimpedance spectroscopy (BIS).

Methods: We designed a miniaturized BIS measurement system and employed a novel calibration method that enables accurate, high-resolution measurements with substantially lower power consumption than conventional approaches. Using this state-of-the-art wearable BIS measurement system, we developed a differential measurement technique for robust assessment of ankle edema.

View Article and Find Full Text PDF