Context And Results: Site-directed spin labeling (SDSL) combined with electron paramagnetic resonance spectroscopy methods has been successfully used to predict the structures of nucleic acids. These methods measure the distances between spin labels yielding distance equations that are solved using numerical algorithms to provide one or several structural predictions. In this work, the minimum number of SDSL distance measurements and distance measurement types required to predict a unique nucleic acid structure were investigated.
View Article and Find Full Text PDFMultiplexed imaging, which allows for the interrogation of multiple molecular features simultaneously, is vital for addressing numerous challenges across biomedicine. Optically unique surface-enhanced Raman scattering (SERS) nanoparticles (NPs) have the potential to serve as a vehicle to achieve highly multiplexed imaging in a single acquisition, which is non-destructive, quantitative, and simple to execute. When using laser excitation at 785 nm, which allows for a lower background from biological tissues, near infrared (NIR) dyes can be used as Raman reporters to provide high Raman signal intensity due to the resonance effect.
View Article and Find Full Text PDFThe prosthetic heart valve is vulnerable to dysfunction after surgery, thus a frequent assessment is required. Doppler electrocardiography and its quantitative parameters are commonly used to assess the performance of the prosthetic heart valves and provide detailed information on the interaction between the heart chambers and related prosthetic valves, allowing early detection of complications. However, in the case of the presence of subaortic stenosis, the accuracy of Doppler has not been fully investigated in previous studies and guidelines.
View Article and Find Full Text PDFA new formulation of hydrogel dosimeter consisting of ferrous-methylthymol blue (MTB)-polyvinyl alcohol (PVA) cross-linked chemically with glutaraldehyde (GTA) was studied and evaluated by nuclear magnetic resonance analysis by means of the R spin-spin relaxation rate. Previous optical studies of this transparent solid chemically cross-linked gel showed important dosimetric features in terms of sensitivity, auto-oxidation rate, and diffusion. This study shows that the MTB-PVA-GTA dosimeter has a reproducible linear dose response up to 40 Gy.
View Article and Find Full Text PDF2-D spatial compounding has long been investigated to reduce speckle in ultrasound images. To further reduce speckle, several 3-D spatial compounding studies using 1-D and 1.5 D arrays with mechanical translation and position tracking have been reported.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
January 2009
Very large element counts (16,000-65,000) are required for 2-D arrays for 3-D rectilinear imaging. The difficulties in fabricating and interconnecting 2-D arrays with a large number of elements (>5,000) have limited the development of suitable transducers for 3-D rectilinear imaging. In this paper, we propose an alternative solution to this problem by using a dual-layer transducer array design.
View Article and Find Full Text PDFUnder mechanical compression, tissue movements are inherently three-dimensional. 2-D strain imaging can suffer from decorrelation noise caused by out-of-plane tissue movement in elevation. With 3-D strain imaging, all tissue movements can be estimated and compensated, hence minimizing out-of-plane decorrelation noise.
View Article and Find Full Text PDF