Background: Pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH) are severe, progressive diseases characterized by key symptoms such as dyspnea and fatigue. These symptoms impair physical functioning, with patients struggling to perform their daily activities. One traditional measure of physical functioning and exercise capacity is the 6-minute walk test (6MWT).
View Article and Find Full Text PDFIn this study, the signal-to-noise ratio of hyperpolarized (129)Xe human lung magnetic resonance imaging was compared at 1.5 T and 3 T. Experiments were performed at both B(0) fields with quadrature double Helmholtz transmit-receive chest coils of the same geometry with the same subject loads.
View Article and Find Full Text PDFIn hyperpolarised (3)He lung MRI with constant flip angles, the transverse magnetisation decays with each RF excitation imposing a k-space filter on the acquired data. For radial data acquired in an angularly-sequential order, this filter causes streaking, angular shading and loss of spatial resolution in the images. The main aim of this work was to reduce the effects of the RF depletion k-space filter in radial acquisitions.
View Article and Find Full Text PDFWashout of inert gases is a measure of pulmonary function well-known in lung physiology. This work presents a method combining inert gas washout and spatially resolved imaging using hyperpolarized (3) He, thus providing complementary information on lung function and physiology. The nuclear magnetic resonance signal of intrapulmonary hyperpolarized (3) He is used to track the total amount of gas present within the lungs during multiple-breath washout via tidal breathing.
View Article and Find Full Text PDFIn this work, the application of compressed sensing techniques to the acquisition and reconstruction of hyperpolarized (3)He lung MR images was investigated. The sparsity of (3)He lung images in the wavelet domain was investigated through simulations based on fully sampled Cartesian two-dimensional and three-dimensional (3)He lung ventilation images, and the k-spaces of 2D and 3D images were undersampled randomly and reconstructed by minimizing the L1 norm. The simulation results show that temporal resolution can be readily improved by a factor of 2 for two-dimensional and 4 to 5 for three-dimensional ventilation imaging with (3)He with the levels of signal to noise ratio (SNR) (approximately 19) typically obtained.
View Article and Find Full Text PDFJ Magn Reson Imaging
August 2009
Purpose: To compare susceptibility effects in hyperpolarized (3)He lung MRI at the clinically relevant field strengths of 1.5T and 3T.
Materials And Methods: Susceptibility-related B(0) inhomogeneity was evaluated on a macroscopic scale by B(0) field mapping via phase difference.